Design of dual Beam multi-wavelength UV-visible absorbance detectors based on CCD

被引:0
|
作者
Shen Shuang [1 ]
Tang Zhen-an [1 ]
Li Tong [2 ]
机构
[1] Dalian Univ Technol, Dalian 116024, Peoples R China
[2] Dalian Elite Analyt Instruments Co Ltd, Dalian 116011, Peoples R China
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Because the general multi-wavelength UV-Visible absorbance detector cannot avoid the noise and drift resulting from the intensity fluctuation of the light source, a dual beam multi-wavelength UV-Visible detector based on OCD was designed. The ray of light source is divided into a signal ray and a reference ray by the beam splitter after it passes through the chopper. The signal ray shines into the sample cell. The signal ray passing through the sample cell falls onto a concave mirror which focuses it onto a slot that is imaged on one portion of COD by a concave grating. The reference ray is imaged on the other portion of CCD by the concave grating after the slot. The signal spectrum, the reference spectrum and the dark current of COD can be measured on the same COD under the cooperation of the optical system and accessorial circuits. The real-time compensation for the signal spectrum by using the reference spectrum and the dark current of OCD can effectively depress the noise and drift of the detector. The short-term noise is 10(-5) AU and the drift is 10(-4) AU/h.
引用
收藏
页码:339 / 341
页数:3
相关论文
共 50 条
  • [11] Use of multi-wavelength UV/visible spectroscopy to monitor protein structure.
    Narayanan, S
    Potter, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 24 - BIOL
  • [12] Use of multi-wavelength UV/visible spectroscopy to monitor protein structure.
    Narayanan, S
    Potter, RL
    GarciaRubio, LH
    BIOCHEMISTRY, 1996, 35 (28) : 24 - 24
  • [13] Design of UV-Visible Dual-spectrum Image Fusion System Based on DSP Technology
    Li, Wei
    Chen, Lixun
    Pang, Qichang
    Li, Guixia
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2392 - +
  • [14] Design of an Achromatic Graphene Oxide Metalens with Multi-Wavelength for Visible Light
    Chen, Yuxi
    Ding, Yongchang
    Yu, Haowen
    Li, Xueyan
    PHOTONICS, 2024, 11 (03)
  • [15] Constellation Design for Channel Precompensation in Multi-Wavelength Visible Light Communications
    Drost, Robert J.
    Sadler, Brian M.
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2014, 62 (06) : 1995 - 2005
  • [17] Correlation between the Track Density and Absorbance of Alpha Particles using CR-39 Detectors from UV-Visible Spectrum
    Ridha, Ali Abdulwahab
    Kadhim, Nada Farhan
    Mohammed, Nadheer Jasim
    JOURNAL OF PHYSICAL SCIENCE, 2019, 30 (02) : 37 - 49
  • [18] Array based design of multi-wavelength fluorescence system
    Estes, C
    Powers, L
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3153 - 3154
  • [19] Design of multi-wavelength demultiplexing coupler based on DBS algorithm
    Chen, Yutai
    Yuan, Huan
    Zhang, Zhaojian
    Ma, Hansi
    Chen, Jian
    Li, Xin
    Yang, Junbo
    OPTICS COMMUNICATIONS, 2023, 549
  • [20] Design of multi-wavelength tunable filter based on Lithium Niobate
    Zhang, Ailing
    Yao, Yuan
    Zhang, Yue
    Song, Hongyun
    OPTICS COMMUNICATIONS, 2018, 415 : 13 - 17