PULSE-ECHO IMAGING USING A NONDIFFRACTING BEAM TRANSDUCER

被引:63
|
作者
LU, JY
GREENLEAF, JF
机构
[1] Biodynamics Research Unit, Department of Physiology and Biophysics, Mayo Clinic, Rochester
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1991年 / 17卷 / 03期
关键词
NONDIFFRACTING BEAM; NONDIFFRACTING TRANSDUCER; ULTRASONIC TRANSDUCER; BESSEL BEAM; GAUSSIAN BEAM; PULSE-ECHO IMAGING; TISSUE SAMPLES; TISSUE EQUIVALENT PHANTOM; CALIBRATION OF RECEIVER; DYNAMIC FOCUSING;
D O I
10.1016/0301-5629(91)90048-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional ultrasonic transducers generate beams that diffract as they travel. This phenomenon causes images produced in B-mode to be degraded in the far-field of the transducers. Focused transducers are used to improve image quality. Unfortunately, focused transducers have short depth of field. Although multiple pulse transmissions focused at several depths are used to increase the effective depth of field, imaging frame rate is reduced dramatically leading to blurred images of moving objects such as the heart. We present a family of transducers that produce nondiffracting beams of large depth of field. Therefore, uniformly high resolution throughout the imaging area can be obtained without sacrificing the imaging frame rate. In addition, the nondiffracting property of these beams makes the correction for beam diffraction negligible in tissue characterization. This paper reports the results of computer simulations as well as in vitro and in vivo pulse-echo imaging experiments with a nondiffracting transducer. Images are compared to those obtained by conventional focused Gaussian shaded beam transducers and a commercial ACUSON 128 B-scanner. The new transducer has much longer depth of field with higher sidelobes than conventional transducers of the same aperture. Sidelobes can be reduced using the new transducer to transmit and the dynamically focused transducer to receive.
引用
收藏
页码:265 / 281
页数:17
相关论文
共 50 条
  • [21] ANALYSIS OF A PULSE-ECHO ULTRASOUND TAPERED PHASED-ARRAY TRANSDUCER
    BENKESER, PJ
    GOFF, EF
    RICE, WO
    ULTRASONICS, 1987, 25 (06) : 376 - 376
  • [22] Initial pulse-echo imaging results with one-dimensional capacitive micromachined ultrasonic transducer arrays
    Oralkan, Ö
    Jin, XC
    Kaviani, K
    Ergun, AS
    Degertekin, FL
    Karaman, M
    Khuri-Yakub, BT
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 959 - 962
  • [23] Spice Model of a Piezo-Electric Transducer for Pulse-Echo System
    Khan, Saleem
    Taube, William
    Yogeswaran, Nivasan
    Heidari, Hadi
    Dahiya, Ravinder
    2015 11TH CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), 2015, : 334 - 337
  • [24] Optimization of pulse-echo array transducer system for identification of specified targets
    Pedersen, PC
    Wan, L
    ACOUSTICAL IMAGING, VOL 26, 2002, 26 : 373 - 380
  • [25] Finite-difference modelling of pulse-echo scattering using a water-coupled transducer
    Stacey, R
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 19A AND 19B, 2000, 509 : 113 - 120
  • [26] Method for decreasing speckle in pulse-echo acoustical imaging
    Univ of Science and Technology of, China, Hefei, China
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 1997, 17 (02): : 97 - 103
  • [27] ULTRASONIC TRANSMISSION TOMOGRAPHY AND PULSE-ECHO IMAGING OF THE BREAST
    KOCH, R
    WHITING, JF
    PRICE, DC
    MCCAFFREY, JF
    ULTRASONIC IMAGING, 1982, 4 (02) : 188 - 189
  • [28] Efficient transmit beamforming in pulse-echo ultrasonic imaging
    Cincotti, G
    Cardone, G
    Gori, P
    Pappalardo, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) : 1450 - 1458
  • [29] Enhanced resolution pulse-echo imaging with stabilized pulses
    Chen, Shujie
    Parker, Kevin J.
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)
  • [30] A regularized inverse approach to ultrasonic pulse-echo imaging
    Lavarello, Roberto
    Kamalabadi, Farzad
    O'Brien, William D., Jr.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (06) : 712 - 722