INACCURACY OF 7 POPULAR SPHYGMOMANOMETERS FOR HOME MEASUREMENT OF BLOOD-PRESSURE

被引:76
|
作者
OBRIEN, E
MEE, F
ATKINS, N
OMALLEY, K
机构
[1] Blood Pressure Unit, Beaumont Hospital
关键词
Measurement of blood pressure; Self-measurement of blood pressure; Validation of blood pressure devices;
D O I
10.1097/00004872-199007000-00005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Seven models, available commercially for the self-measurement of blood pressure, were subjected to a validation procedure in which three devices of each model were tested by observers who were trained to a high standard of accuracy. The models were the Omron HEM-400C, the Philips HP5308, the Healthcheck ‘Cuffless’ CX-5 060020, the Nissei Analogue Monitor, the Philips HP5306/B, the Systema Dr MI-150 and the Fortec Dr MI-100. The validation programme had a number of unique features which included assessment of interdevice variability before and after 1 month of home use, and a new form of analysis, which we term ‘clinical’, based on the likely influence of three grades of device inaccuracy on patient management. In the main validation phase, one device of each model was compared with simultaneous measurements made by two 'blinded' observers using a standard mercury sphygmomanometer (PyMaH Corporation, New Jersey, USA) in the same arm in 85 subjects with a wide range of blood pressures. Three models (the Healthcheck ‘Cuffless’ CX-5 060020, the Systema Dr MI-150 and the Fortec Dr MI-100) failed the interdevice variability tests and did not reach the main validation test. Two models (the Omron HEM-400C and the Philips HP5306/B) failed on the criteria set down by the American National Standard for Electronic or Automated Sphygmomanometers, as well as the ‘clinical’ criteria. The remaining two models (the Nissei Analogue Monitor and the Philips HP5308) were acceptable for the measurement of systolic blood pressure by both methods of analysis but failed In the ‘clinical’ analysis for diastolic blood pressure. The mercury sphygmomanometer was comfortably within the criteria for both methods of analysis. © Current Science Ltd.
引用
收藏
页码:621 / 634
页数:14
相关论文
共 50 条
  • [21] Assessment of Sphygmomanometers: a Proposal for Excellence in Blood Pressure Measurement
    Nobre, Fernando
    Coelho, Eduardo Barbosa
    Lessa do Valle Dallora, Maria Eulalia
    de Figueiredo, Pio Antonio
    Fernandes Ferreira, Ana Beatriz
    Oliveira Ferreira da Rosa, Maria Alice
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2009, 93 (02) : E27 - E29
  • [22] HOME VERSUS OFFICE MONITORING OF BLOOD-PRESSURE - A EUROPEAN MULTICENTER STUDY ON HIGH BLOOD-PRESSURE (HOME BLOOD-PRESSURE)
    CLEMENT, DL
    JOURNAL OF HYPERTENSION, 1989, 7 : S356 - S356
  • [23] Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice?
    Myers, Martin G.
    Valdivieso, Miguel
    Chessman, Mary
    Kiss, Alexander
    BLOOD PRESSURE MONITORING, 2010, 15 (06) : 300 - 304
  • [24] PROBLEMS AND ERRORS IN THE MEASUREMENT AND INTERPRETATION OF BLOOD-PRESSURE .10. BLOOD-PRESSURE MEASUREMENT AT THE HOSPITAL, OFFICE, HOME, DRUGSTORE AND IN PUBLIC
    不详
    MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1980, 122 (44): : 51 - &
  • [25] BLOOD-PRESSURE MEASUREMENT
    CARLISLE, R
    BRITISH MEDICAL JOURNAL, 1979, 2 (6204): : 1582 - 1583
  • [26] MEASUREMENT OF BLOOD-PRESSURE
    LONDE, S
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1976, 115 (07) : 609 - 609
  • [27] BLOOD-PRESSURE MEASUREMENT
    ANLAUF, M
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1972, 97 (40) : 1522 - &
  • [28] BLOOD-PRESSURE MEASUREMENT
    不详
    CANADIAN FAMILY PHYSICIAN, 1993, 39 : 2532 - 2532
  • [29] BLOOD-PRESSURE MEASUREMENT
    HOLLDACK, K
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1977, 102 (15) : 589 - 589
  • [30] BLOOD-PRESSURE MEASUREMENT
    LEVERTON, MJ
    LANCET, 1991, 337 (8738): : 429 - 429