The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

被引:35
|
作者
Chung, Kwangzoo [1 ]
Han, Youngyih [1 ]
Kim, Jinsung [1 ]
Ahn, Sung Hwan [1 ]
Ju, Sang Gyu [1 ]
Jung, Sang Hoon [1 ]
Chung, Yoonsun [1 ]
Cho, Sungkoo [1 ]
Jo, Kwanghyun [1 ]
Shin, Eun Hyuk [1 ]
Hong, Chae-Seon [1 ]
Shin, Jung Suk [1 ]
Park, Seyjoon [1 ]
Kim, Dae-Hyun [1 ]
Kim, Hye Young [1 ]
Lee, Boram [1 ]
Shibagaki, Gantaro [2 ]
Nonaka, Hideki [2 ]
Sasai, Kenzo [2 ]
Koyabu, Yukio [2 ]
Choi, Changhoon [1 ]
Huh, Seung Jae [1 ]
Ahn, Yong Chan [1 ]
Pyo, Hong Ryull [1 ]
Lim, Do Hoon [1 ]
Park, Hee Chul [1 ]
Park, Won [1 ]
Ryul, Dong [1 ]
Noh, Jae Myung [1 ]
Yu, Jeong Il [1 ]
Song, Sanghyuk [1 ]
Lee, Ji Eun [1 ]
Lee, Bomi [1 ]
Choi, Doo Ho [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiat Oncol, 81 Irwon Ro, Seoul 06351, South Korea
[2] Sumitomo Heavy Ind Ltd, Ind Equipment Div, Niihama, Japan
来源
RADIATION ONCOLOGY JOURNAL | 2015年 / 33卷 / 04期
关键词
Proton therapy; Proton beam therapy; Particle accelerator; Radiation oncology;
D O I
10.3857/roj.2015.33.4.337
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [1] Status of the proton therapy facility at the National Cancer Center, Korea
    Kim, Jongwon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 738 - 742
  • [2] The Downstream "Halo" Effect of a Proton Therapy Center on an Academic Medical Center
    Remick, J.
    Chhabra, A. M.
    Bentzen, S. M.
    Simone, C. B., II
    Nichols, E. M.
    Suntharalingam, M.
    Regine, W. F., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E427 - E428
  • [3] A proton therapy system in Nagoya Proton Therapy Center
    Toshito, Toshiyuki
    Omachi, Chihiro
    Kibe, Yoshiaki
    Sugai, Hiroyuki
    Hayashi, Kensuke
    Shibata, Hiroki
    Yasui, Keisuke
    Tanaka, Kenichiro
    Yamamoto, Takahiro
    Yoshida, Atsushi
    Nikawa, Eiki
    Asai, Kumiko
    Shimomura, Akira
    Okumura, Ikuyo
    Suzuki, Toshinori
    Kinou, Hideto
    Isoyama, Shigeru
    Ogino, Hiroyuki
    Iwata, Hiromitsu
    Shibamoto, Yuta
    Mizoe, Jun'etsu
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (03) : 645 - 654
  • [4] A proton therapy system in Nagoya Proton Therapy Center
    Toshiyuki Toshito
    Chihiro Omachi
    Yoshiaki Kibe
    Hiroyuki Sugai
    Kensuke Hayashi
    Hiroki Shibata
    Keisuke Yasui
    Kenichiro Tanaka
    Takahiro Yamamoto
    Atsushi Yoshida
    Eiki Nikawa
    Kumiko Asai
    Akira Shimomura
    Ikuyo Okumura
    Toshinori Suzuki
    Hideto Kinou
    Shigeru Isoyama
    Hiroyuki Ogino
    Hiromitsu Iwata
    Yuta Shibamoto
    Jun’etsu Mizoe
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 645 - 654
  • [5] The proton therapy nozzles at Samsung Medical Center: A Monte Carlo simulation study using TOPAS
    Kwangzoo Chung
    Jinsung Kim
    Dae-Hyun Kim
    Sunghwan Ahn
    Youngyih Han
    Journal of the Korean Physical Society, 2015, 67 : 170 - 174
  • [6] The Proton Therapy Nozzles at Samsung Medical Center: A Monte Carlo Simulation Study using TOPAS
    Chung, Kwangzoo
    Kim, Jinsung
    Kim, Dae-Hyun
    Ahn, Sunghwan
    Han, Youngyih
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 170 - 174
  • [7] The Midwest Proton Therapy Center
    Bloch, C
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 1253 - 1255
  • [8] NICE PROTON THERAPY CENTER
    CHAUVEL, P
    BRASSART, N
    HERAULT, J
    COURDI, A
    PATHOLOGIE BIOLOGIE, 1993, 41 (01): : 126 - 128
  • [9] DESIGN OF A HOSPITAL-BASED PROTON-BEAM THERAPY CENTER
    MILLER, DW
    SLATER, JM
    AWSCHALOM, MW
    ALLEN, MA
    MEDICAL PHYSICS, 1987, 14 (03) : 468 - 468
  • [10] Proton Therapy Facility Project in National Cancer Center, Korea
    Kim, J
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 43 : S50 - S54