摘要
Introduction: Anterior Cruciate Ligament (ACL) is as one of the most frequently injured ligaments in the modern contact sports scenario. Graft fixations can be achieved during anterior cruciate ligament (ACL) reconstructions by using either bioabsorbable screws or metal screws. The objective of this study was to compare the functional outcomes after bioabsorbable and metallic interference screw fixations in arthroscopic anterior cruciate ligament reconstructions done by using hamstring grafts. Materials and Methods: This was a prospective, randomized study. Patients in Group 1 received bioabsorbable interference screws and patients in Group 2 received metallic interference screws. Arthroscopic assisted, anterior cruciate ligament reconstructions with the use of hamstring grafts which were fixed proximally with endobuttons and distally with bioabsorbable or metallic interference screws, were undertaken. Progress in functional outcomes was assessed by using Mann Whitney U-test. Functional outcomes in the two groups were compared by using independent t-test. Observation and Results: In each group, there were statistically significant improvements in functional outcomes over successive follow-ups, which were seen on basis on Mann-Whitney U-test. The comparison of functional outcomes between the two groups, done by using independent t-test, showed no statistically significant differences between the two groups at 3 months, 6 months and 1 year of follow-up. p-value < 0.05 was considered to be significant in our study. Conclusion: In our prospective study of comparison of functional outcomes between bioabsorbable and metallic interference screws in arthroscopic anterior cruciate ligament reconstuctions, which were evaluated by using Tegner activity scale and Lysholm knee scoring scale for a period of 1 year, no statistically significant difference was found. However, further authentication is required by doing long term studies.
引用
下载
收藏
页码:LC1 / LC3
页数:3
相关论文
共 50 条
  • [1] BIOMECHANICAL PERFORMANCE OF METALLIC AND BIOABSORBABLE INTERFERENCE SCREW FOR TIBIAL GRAFT FIXATION IN ACL RECONSTRUCTION
    Ocampo More, Ari Digiacomo
    Almeida Pizzolatti, Andre Luiz
    Fancello, Eduardo
    de Mello Roesler, Carlos Rodrigo
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [2] Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction?
    Papalia, Rocco
    Vasta, Sebastiano
    D'Adamio, Stefano
    Giacalone, Antonino
    Maffulli, Nicola
    Denaro, Vincenzo
    BRITISH MEDICAL BULLETIN, 2014, 109 (01) : 19 - 29
  • [3] Recurrent locking of knee joint caused by intraarticular migration of bioabsorbable tibial interference screw after arthroscopic ACL reconstruction
    Andreas Appelt
    Martin Baier
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 378 - 380
  • [4] Recurrent locking of knee joint caused by intraarticular migration of bioabsorbable tibial interference screw after arthroscopic ACL reconstruction
    Appelt, Andreas
    Baier, Martin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (04) : 378 - 380
  • [5] Arthroscopic biceps tenodesis using a bioabsorbable interference screw
    Lo, IKY
    Burkhart, SS
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (01): : 85 - 95
  • [6] Arthroscopic ACL reconstruction with reverse "Y"-plasty grafts and fixation in the femur with either a bioabsorbable interference screw or an Endobutton
    Ping, Li Wei
    Bin, Song
    Rui, Yang
    Yang, Song
    Zheng, Zhang Zheng
    Yue, Ding
    KNEE, 2012, 19 (02): : 78 - 83
  • [7] Comparison between a novel human cortical bone screw and bioabsorbable interference screw for graft fixation of ACL reconstruction
    Shen, X. -Z.
    Qu, F.
    Li, C. -B.
    Qi, W.
    Lu, X.
    Li, H. -L.
    Guo, Q.
    Wang, J. -T.
    Zhao, G.
    Liu, Y. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 111 - 118
  • [8] Radiological findings of osteitis caused by the protracted absorption of a bioabsorbable screw after ACL reconstructions - a case report
    不详
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (04): : 393 - 394
  • [9] MRI evaluation of the tibial tunnel/screw/tendon interface after ACL reconstruction using a bioabsorbable interference screw
    Singhal, Manuj C.
    Holzhauer, Markus
    Powell, David
    Johnson, Darren L.
    ORTHOPEDICS, 2008, 31 (06) : 575 - 579
  • [10] In Vitro Investigation of the Fixation Performance of a Bioabsorbable Magnesium ACL Interference Screw Compared to a Conventional Interference Screw
    Siroros, Nad
    Merfort, Ricarda
    Liu, Yu
    Praster, Maximilian
    Hildebrand, Frank
    Michalik, Roman
    Eschweiler, Joerg
    LIFE-BASEL, 2023, 13 (02):