VISCOSE ODORS IN AMBIENT AIR - A STUDY OF THE RELATIONSHIP BETWEEN THE DETECTABILITY OF VISCOSE ODORS AND CONCENTRATIONS OF H2S AND CS2 IN AMBIENT AIR

被引:4
|
作者
BRUNEKREEF, B [1 ]
HARSSEMA, H [1 ]
机构
[1] AGR UNIV WAGENINGEN,DEPT AIR POLLUT,NL-6709 PD WAGENINGEN,NETHERLANDS
来源
WATER AIR AND SOIL POLLUTION | 1980年 / 13卷 / 04期
关键词
Odor control - Rayon;
D O I
10.1007/BF02191844
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The odor problem around a viscose rayon factory in Arnhem, The Netherlands, was studied quantitatively in a 4 mo program. Methods were developed to relate systematic odor observations in the field to momentary concentrations of two different tracer gases (H//2S and CS//2). Also a relationship between odor observations and 1 h average CS//2-concentrations was assessed. A simple method is described to characterize the long term average odor detectability in the vicinity of the source, and to estimate the impact of an emission reduction on odor detectability.
引用
收藏
页码:439 / 446
页数:8
相关论文
共 50 条
  • [1] SENSORS MONITOR H2S IN AMBIENT AIR
    不详
    JOURNAL OF ENVIRONMENTAL HEALTH, 1992, 55 (03) : 55 - 55
  • [2] Hydrogen sulfide (H2S) in urban ambient air
    Kourtidis, K.
    Kelesis, A.
    Petrakakis, M.
    ATMOSPHERIC ENVIRONMENT, 2008, 42 (32) : 7476 - 7482
  • [3] Screening of Absorbents for Viscose Fiber CS2 Waste Air and Absorption-Desorption Process
    Xiao, Ruixue
    Chao, Kefan
    Liu, Ju
    Chen, Muhua
    Zhu, Xinbao
    Fu, Bo
    ATMOSPHERE, 2023, 14 (03)
  • [4] H2S IN REFINERIES AND NATURAL-GAS TREATMENT PLANTS - EMISSION AND AMBIENT AIR CONCENTRATIONS
    GASIOROWSKI, K
    STAUB REINHALTUNG DER LUFT, 1979, 39 (05): : 189 - 191
  • [5] DEGRADATION OF H2S AND CS2 IN EXHAUST AIR BY IRRADIATION WITH 500 KEV ELECTRONS
    WIESBOCK, R
    PROKSCH, E
    KERNTECHNIK, 1976, 18 (8-9) : 390 - 393
  • [6] Assessment of H2S and BTEX concentrations in ambient air using passive sampling method and the health risks
    Ulutas, Kadir
    Kaskun, Songul
    Demir, Selami
    Dincer, Faruk
    Pekey, Hakan
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2021, 193 (07)
  • [7] Assessment of H2S and BTEX concentrations in ambient air using passive sampling method and the health risks
    Kadir Ulutaş
    Songül Kaskun
    Selami Demir
    Faruk Dinçer
    Hakan Pekey
    Environmental Monitoring and Assessment, 2021, 193
  • [8] Degradation of H2S and CS2 in Exhaust Air by Irradiation with 500 keV Electrons.
    Wiesboeck, Rainer
    Proksch, Emil
    1600, (18): : 8 - 9
  • [9] Desulfurization of air at high and low H2S concentrations
    Elsayed, Yehya
    Seredych, Mykola
    Dallas, Andrew
    Bandosz, Teresa J.
    Chemical Engineering Journal, 2009, 155 (03): : 594 - 602
  • [10] Desulfurization of air at high and low H2S concentrations
    Elsayed, Yehya
    Seredych, Mykola
    Dallas, Andrew
    Bandosz, Teresa J.
    CHEMICAL ENGINEERING JOURNAL, 2009, 155 (03) : 594 - 602