BIOELECTRICAL IMPEDANCE ANALYSIS IN THE MEASUREMENT OF THE BODY-COMPOSITION OF SURGICAL PATIENTS

被引:23
|
作者
FEARON, KCH
RICHARDSON, RA
HANNAN, J
COWAN, S
WATSON, W
SHENKIN, A
GARDEN, OJ
机构
[1] University Department of Surgery, Royal Infirmary of Edinburgh, Edinburgh
关键词
D O I
10.1002/bjs.1800790516
中图分类号
R61 [外科手术学];
学科分类号
摘要
The evaluation of nutritional status in surgical patients remains a difficult problem. Bioelectrical impedance analysis (BIA) is a new method of body composition analysis which is easily performed at the bedside. This study determined the accuracy of BIA in the measurement of total body water (TBW) and potassium (TBK) in a heterogeneous group of surgical patients. The resistance and reactance components of impedance were measured with a whole body impedance analyser. Tritiated water dilution and whole body monitoring were the reference methods for TBW and TBK analysis. With the BIA technique the coefficient of variation for the estimation of TBW was 8.1 per cent and for TBK was 6.4 per cent. Allowing for the errors of the reference methods these results show that BIA is of limited value in the estimation of TBW but may provide a useful index of TBK.
引用
收藏
页码:421 / 423
页数:3
相关论文
共 50 条
  • [1] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    [J]. CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775
  • [2] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1987, 45 (04): : 830 - 830
  • [3] BIOELECTRICAL IMPEDANCE ANALYSIS FOR BODY-COMPOSITION - CLINICAL-EVALUATION IN GENERAL SURGICAL PATIENTS
    SCHROEDER, D
    CHRISTIE, PM
    HILL, GL
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1990, 14 (02) : 129 - 133
  • [4] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    WALKER, M
    RODHAM, D
    FULCHER, GR
    CLAYTON, B
    FARRER, M
    ALBERTI, KGMM
    [J]. LANCET, 1993, 341 (8842): : 448 - 448
  • [5] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    DEVRIES, PMJM
    KOUW, PM
    OLTHOF, CG
    DEVRIES, JPPM
    DONKER, AJM
    [J]. LANCET, 1993, 341 (8844): : 570 - 570
  • [6] BIOELECTRICAL IMPEDANCE AND BODY-COMPOSITION
    不详
    [J]. LANCET, 1992, 340 (8834-5): : 1511 - 1511
  • [7] BIOELECTRICAL IMPEDANCE FOR THE ASSESSMENT OF BODY-COMPOSITION OF DIALYZED PATIENTS
    BIASIOLI, S
    PETROSINO, Z
    CAVALLI, L
    ZAMBELLO, A
    CESARO, A
    FAZION, S
    [J]. CLINICAL NEPHROLOGY, 1989, 31 (05) : 274 - 275
  • [8] PREPARATORY POSTURAL POSITIONS AND BODY-COMPOSITION MEASUREMENT BY BIOELECTRICAL IMPEDANCE
    THOMAS, TR
    KOLKHORST, FW
    LONDEREE, BR
    MELKERSONGRANRYD, M
    LINSENBARDT, ST
    RUTHERFORD, M
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1990, 61 (02) : 206 - 209
  • [9] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [10] VALIDATION OF BIOELECTRICAL-IMPEDANCE ANALYSIS AS A MEASUREMENT OF CHANGE IN BODY-COMPOSITION IN OBESITY
    KUSHNER, RF
    KUNIGK, A
    ALSPAUGH, M
    ANDRONIS, PT
    LEITCH, CA
    SCHOELLER, DA
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 52 (02): : 219 - 223