Management of anastomotic biliary stricture after liver transplantation: metal versus plastic stent

被引:19
|
作者
Facciorusso, Antonio [1 ]
Rosca, Elena Cecilia [2 ]
Ashimi, Adewale [3 ]
Ugoeze, Kenneth C. [4 ]
Pathak, Utkarsha [5 ]
Infante, Vanessa [6 ]
Muscatiello, Nicola [1 ]
机构
[1] Univ Foggia, Dept Med Sci, Gastroenterol Unit, Viale L Pinto 1, I-71100 Foggia, Italy
[2] Univ Med & Pharm Victor Babes Timisoara, Dept Neurol, Timisoara, Romania
[3] Fed Med Ctr Birnin Kudu, Dept Obstet & Gynecol, Birnin Kudu, Jigawa State, Nigeria
[4] Univ Port Harcourt, Dept Pharmaceut & Pharmaceut Technol, Port Harcourt, Nigeria
[5] Guru Gobind Singh Indraprastha Univ, Sch Environm, New Delhi, India
[6] Univ Sao Paulo, Dept Infect Dis, Sao Paulo, Brazil
来源
ANNALS OF GASTROENTEROLOGY | 2018年 / 31卷 / 06期
关键词
Fully-covered self-expandable metal stents; plastic stents; orthotopic liver transplantation; endoscopic retrograde cholangiopancreatography; meta-analysis;
D O I
10.20524/aog.2018.0297
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Post-transplant anastomotic biliary strictures remain refractory to endoscopic therapy in a considerable number of cases. The aim of this meta-analysis was to compare fully-covered self-expandable metal and plastic stents in the management of post-transplant biliary strictures. Methods A meta-analysis was performed using a random effects model; results were expressed as odds ratio (OR) and mean standardized difference. The primary outcome was stricture resolution, while recurrence rate after stent placement, treatment time, and safety of the procedure were the secondary outcomes. Results Through a systematic literature review until October 2017, we identified 7 studies, of which 4 were randomized controlled trials. Stricture resolution was slightly higher with metal stents, with no statistical difference between the two procedures (OR 1.38, 95% confidence interval [CI] 0.60-3.15; P=0.45) and low heterogeneity (I-2=6%). Stricture recurrence showed a non-significant trend in favor of plastic stents (OR 1.82, 95% CI 0.52-6.31, P=0.35). Endoscopic retrograde cholangiopancreatography with placement of metal stents offered a significant improvement in terms of reduced treatment time (mean standardized difference: -3.58 months, 95% CI -6.23 to -0.93; P=0.008), but with more frequent complications, although not significantly so (OR 2.34, 95% CI 0.75-7.25; P=0.14). Sensitivity analysis confirmed all the findings. Conclusion Metal stents appear to be a promising tool that can decrease treatment time, although there is still no clear evidence of their superiority over plastic stents in terms of efficacy.
引用
收藏
页码:728 / +
页数:9
相关论文
共 50 条
  • [1] TREATMENT OF BILIARY ANASTOMOTIC STRICTURE AFTER LIVER TRANSPLANTATION: IS METAL BETTER THAN PLASTIC?
    Hajifathalian, Kaveh
    Skaf, Daniel A.
    Katz, Philip O.
    Samstein, Benjamin
    Brown, Robert S.
    Fortune, Brett E.
    Sharaiha, Reem Z.
    [J]. GASTROENTEROLOGY, 2021, 160 (06) : S816 - S817
  • [2] Liver Graft Failure after Plastic Stent Removal of an Anastomotic Biliary Stricture
    Chun, Jung Won
    Yi, Nam-Joon
    Kim, Haeryoung
    Paik, Woo Hyun
    [J]. KOREAN JOURNAL OF GASTROENTEROLOGY, 2022, 79 (05): : 217 - 221
  • [3] Management of anastomotic biliary stricture after liver transplantation and impact on survival
    Jarlot-Gas, Cecile
    Muscari, Fabrice
    Mokrane, Fatima-Zohra
    Del Bello, Arnaud
    Culetto, Adrian
    Buscail, Etienne
    Pere, Guillaume
    Fares, Nadim
    Peron, Jean -Marie
    Cuellar, Emmanuel
    Barange, Karl
    Kamar, Nassim
    Suc, Bertrand
    Maulat, Charlotte
    [J]. HPB, 2021, 23 (08) : 1259 - 1268
  • [4] Metal stent versus plastic stent for post liver transplant anastomotic biliary strictures
    Kaffes, Arthur
    Gill, Raghubinder S.
    Griffin, Sean P.
    Corte, Crispin J.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 58 - 58
  • [5] Placement of removable metal biliary stent in post-orthotopic liver transplantation anastomotic stricture
    Tee, Hoi-Poh
    James, Martin W.
    Kaffes, Arthur J.
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2010, 16 (28) : 3597 - 3600
  • [6] Placement of removable metal biliary stent in post-orthotopic liver transplantation anastomotic stricture
    Hoi-Poh Tee
    Martin W James
    Arthur J Kaffes
    [J]. World Journal of Gastroenterology, 2010, 16 (28) : 3597 - 3600
  • [7] Managing the post-liver transplantation anastomotic biliary stricture: multiple plastic versus metal stents: a systematic review
    Kao, Dina
    Zepeda-Gomez, Sergio
    Tandon, Puneeta
    Bain, Vince G.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2013, 77 (05) : 679 - 691
  • [8] Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial
    Martins, Fernanda Prata
    De Paulo, Gustavo Andrade
    Contini, Monica L. C.
    Ferrari, Angelo Paulo
    [J]. GASTROINTESTINAL ENDOSCOPY, 2018, 87 (01) : 131 - +
  • [9] Multiple plastic stents versus covered metal stent for treatment of anastomotic biliary strictures after liver transplantation: a prospective, randomized, multicenter trial
    Tal, Andrea Oliver
    Finkelmeier, Fabian
    Filmann, Natalie
    Kylaenpaeae, Leena
    Udd, Marianne
    Parzanese, Ilaria
    Cantu, Paolo
    Dechene, Alexander
    Penndorf, Volker
    Schnitzbauer, Andreas
    Friedrich-Rust, Mireen
    Zeuzem, Stefan
    Albert, Joerg G.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2017, 86 (06) : 1038 - 1045
  • [10] ENDOSCOPIC ELECTROINCISION OF DIFFICULT ANASTOMOTIC BILIARY STRICTURE AFTER LIVER TRANSPLANTATION
    Tringali, A.
    Milluzzo, S. M.
    Perri, V
    Costamagna, G.
    [J]. DIGESTIVE AND LIVER DISEASE, 2022, 54 : S154 - S154