PRECLINICAL EVALUATION OF THE RELIABILITY OF A 50 MEV RACETRACK MICROTRON

被引:17
|
作者
MASTERSON, ME
MAGERAS, GS
LOSASSO, T
JORESKOG, E
LARSSON, LG
TSIRAKIS, B
FEBO, R
MOHAN, R
LING, CC
LEIBEL, SA
FUKS, Z
KUTCHER, GJ
机构
[1] MEM SLOAN KETTERING CANC CTR,DEPT RADIAT ONCOL,DEPT MED PHYS,NEW YORK,NY
[2] SCANDITRONIX AB,DIV RADIOTHERAPY,UPPSALA,SWEDEN
关键词
RADIOTHERAPY MACHINE; CONFORMAL RADIOTHERAPY; RACETRACK MICROTRON; COMPUTER CONTROL;
D O I
10.1016/0360-3016(94)90498-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A 50 MeV racetrack microtron has been installed and tested at Memorial Sloan-Kettering Cancer Center. It is designed to execute multi-segment conformal therapy automatically under computer control using scanned X ray and electron beams from 10 to 50 MeV. Prior to acceptance of the machine from the manufacturer, formal reliability testing was carried out. Only in this way could confidence be gained in its usefulness for routine 3D computer-controlled conformal therapy. Materials and Methods: To assess reliability, a set of 25 multi-segment test cases, each consisting of 10 to 17 fixed segments, was developed. The field arrangements and modalities for some of the test cases were identical to 3D conformal treatments that were being delivered with multiple static fields on conventional linear accelerators at our institution. Other cases were designed to explore reliability under more complex sets of conditions. These cases were ''treated'' repeatedly during a total period of 45 hours, over 5 days. During the treatments, ion chambers attached to the head of the machine provided dosimetric data for each field. Data from sensors connected to every set-up parameter (for example, couch positions, gantry angle, collimator leaf positions, etc.) were recorded and verified by an external computer. Results: While preliminary tests indicated an interlock rate of 5%, final reliability test results demonstrated an interlock fault rate of approximately 0.5%. The reproducibility of dosimetric data and geometric setup parameters was within specifications. As an example, leaf position reproducibility in the patient plane was within 0.5 mm for 97% of the setups. The times required to carry out treatments were recorded and compared with the times to carry out identical treatments on a conventional linear accelerator with cerrobend blocks. Areas where additional time savings can be achieved were identified. Conclusion: As an integral part of acceptance testing, the Scanditronix MM50 was rigorously tested for reliability. The machine successfully passed these tests, providing increased confidence in its usefulness for routine 3D conformal therapy.
引用
收藏
页码:1219 / 1227
页数:9
相关论文
共 50 条
  • [1] Mathematical modeling of a 50 MeV racetrack microtron
    Gromov A.M.
    Bulletin of the Russian Academy of Sciences: Physics, 2011, 75 (02) : 232 - 238
  • [2] ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON
    BRAHME, A
    KRAEPELIEN, T
    SVENSSON, H
    ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04): : 305 - 319
  • [3] A 70 Mev racetrack microtron
    Shvedunov, VI
    Ermakov, AN
    Gribov, IV
    Knapp, EA
    Novikov, GA
    Pakhomov, NI
    Shvedunov, IV
    Skachkov, VS
    Sobenin, NP
    Trower, WP
    Yajlijan, VR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 39 - 53
  • [4] ELECTRON-BEAM CHARACTERISTICS OF THE 50-MEV RACETRACK MICROTRON
    KARLSSON, M
    NYSTROM, H
    SVENSSON, H
    MEDICAL PHYSICS, 1992, 19 (02) : 307 - 315
  • [5] BEAM CHARACTERISTICS OF A NEW-GENERATION 50 MEV RACETRACK MICROTRON
    MASTERSON, ME
    CHUI, CS
    FEBO, R
    HUNG, JD
    FUKS, Z
    MOHAN, R
    LING, CC
    KUTCHER, GJ
    BJORK, S
    ENSTROM, J
    MEDICAL PHYSICS, 1995, 22 (06) : 781 - 792
  • [6] THE 50 MEV RACETRACK MICROTRON AT THE ROYAL-INSTITUTE-OF-TECHNOLOGY-STOCKHOLM
    ROSANDER, S
    SEDLACEK, M
    WERNHOLM, O
    BABIC, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 204 (01): : 1 - 20
  • [7] The 75 MeV Racetrack Microtron Eindhoven
    Theuws, WHC
    Botman, JIM
    Hagedoorn, HL
    deLeeuw, RW
    Timmermans, CJ
    PROCEEEDINGS OF THE XVIII INTERNATIONAL LINEAR ACCELERATOR CONFERENCE, VOLS 1 AND 2, 1996, 96 (07): : 92 - 94
  • [8] Mathematical modeling of acceleration in a racetrack microtron at 50 MeV with a limited number of orbits
    A. M. Gromov
    A. A. Vasil’ev
    G. V. Solodukhov
    Atomic Energy, 2008, 104 : 404 - 409
  • [9] MEDICAL APPLICATIONS OF A 50 MEV RACETRACK MICROTRON .2. RADIONUCLIDE PRODUCTION
    NORDELL, B
    BRAHME, A
    REUTHAL, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 785 - 785
  • [10] Mathematical modeling of acceleration in a racetrack microtron at 50 MeV with a limited number of orbits
    Gromov, A. M.
    Vasil'ev, A. A.
    Solodukhov, G. V.
    ATOMIC ENERGY, 2008, 104 (05) : 404 - 409