SECONDARY CATARACT MATERIAL COLLECTED WITH A GLASS CANNULA - A SEM STUDY

被引:5
|
作者
JONGEBLOED, WL
VANDERVEEN, G
DIJK, F
WORST, JGF
机构
[1] Department of Histology and Cellbiology, University of Groningen, Groningen
[2] Eye Physician and Surgeon, Haren
关键词
SECONDARY CATARACT; LENS-FIBERS; CAPSULE EPITHELIUM; SELECTIVE COLLECTION; GLASS CANNULA; SEM;
D O I
10.1007/BF00164851
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Secondary cataract material from three patients, collected with a glass cannula approx. 18, 24 and 30 months respectively after operation, was prepared for SEM examination. For the soft samples this was done by filtration through a millipore filter followed by fixation and drying. The more solid material was suspended in a fixation solution, followed by centrifuging, suspension in 70% ethanol and drying on a specimen-holder. The short residence samples (18 months) showed mainly erythrocytes, some (inflammatory) cells and degenerated lens-fibre material. Most of the more solid material, which was collected more than 20 months after operation, showed fragments of (regenerated) capsule epithelium and pieces of solid lens-fibre material with fragments of capsule epithelium attached.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [1] (AN)AEROBIC BACTERIA FOUND IN SECONDARY-CATARACT MATERIAL - A SEM/TEM STUDY
    KALICHARAN, D
    JONGEBLOED, WL
    LOS, LI
    WORST, JGF
    DOCUMENTA OPHTHALMOLOGICA, 1992, 82 (1-2) : 125 - 133
  • [2] MICROORGANISMS FOUND IN SECONDARY CATARACT MATERIAL OF ECCE PATIENTS, A STUDY WITH SEM AND TEM
    KALICHARAN, D
    JONGEBLOED, WL
    LOS, LI
    WORST, JGF
    EUROPEAN JOURNAL OF MORPHOLOGY, 1993, 31 (1-2): : 103 - 106
  • [3] SOEMMERINGS RING, AN ASPECT OF SECONDARY CATARACT - A MORPHOLOGICAL DESCRIPTION BY SEM
    JONGEBLOED, WL
    DIJK, F
    KRUIS, J
    WORST, JGF
    DOCUMENTA OPHTHALMOLOGICA, 1988, 70 (2-3) : 165 - 174
  • [4] SOME ASPECTS OF CATARACT MORPHOLOGY - A SEM-STUDY
    JONGEBLOED, WL
    DIJK, F
    WORST, JGF
    DOCUMENTA OPHTHALMOLOGICA, 1988, 70 (2-3) : 155 - 163
  • [5] CANNULA FOR OBTAINING ENDOMETRIAL MATERIAL FOR CYTOLOGIC STUDY
    BOUTSELIS, JG
    ULLERY, JC
    OBSTETRICS AND GYNECOLOGY, 1962, 20 (02): : 265 - &
  • [6] Analysis of secondary electron signals collected in the modern field-emission SEM
    Liu, J
    ELECTRON MICROSCOPY 1998, VOL 1: GENERAL INTEREST AND INSTRUMENTATION, 1998, : 479 - 480
  • [7] NEW CANNULA FOR OBTAINING ENDOMETRIAL MATERIAL FOR CYTOLOGIC STUDY
    JORDAN, MJ
    BADER, GM
    OBSTETRICS AND GYNECOLOGY, 1956, 8 (05): : 611 - 612
  • [8] BONE SURFACE IN SECONDARY HYPERPARATHYROIDISM - SEM STUDY
    GEIGER, G
    KREMPIEN, B
    RITZ, E
    CALCIFIED TISSUE RESEARCH, 1977, 22 : 386 - 388
  • [9] EXTRANEOUS MATERIAL ON PLANT SURFACES - SEM STUDY
    DAVIS, DG
    MEOLA, SM
    MULLINS, JS
    WEED SCIENCE, 1976, 24 (03) : 341 - 347
  • [10] STUDY ON INTERACTION OF ACTIVE INGREDIENT AND PLASTIC MATERIAL IN A PERFUSION CANNULA
    LEFEBVRE, C
    ROBERT, H
    BATTIST, B
    5TH INTERNATIONAL CONFERENCE ON PHARMACEUTICAL TECHNOLOGY, VOLS 1-5, 1989, : B411 - B420