PRACTICAL LOW-COST STAND SIT SYSTEM FOR MID-THORACIC PARAPLEGICS

被引:15
|
作者
EWINS, DJ [1 ]
TAYLOR, PN [1 ]
CROOK, SE [1 ]
LIPCZYNSKI, RT [1 ]
SWAIN, ID [1 ]
机构
[1] ODSTOCK HOSP,DEPT MED PHYS,SALISBURY SP2 8BJ,WILTS,ENGLAND
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1988年 / 10卷 / 02期
关键词
BIOMECHANICS - Musculoskeletal Systems - BIOMEDICAL EQUIPMENT - Wheelchairs - COMPUTER SOFTWARE - Medical Applications - PROSTHETICS - Sensory Feedback;
D O I
10.1016/0141-5425(88)90098-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of functional electrical stimulation (FES) to enable paraplegics to stand is not new or indeed difficult to undertake under laboratory conditions. However, there are substantial problems to overcome before such systems can be used routinely by patients without professional supervision. The overriding consideration has to be one of safety, i. e. the system must be 'fail safe'. Second, the system must be quick and easy to use in a wide variety of locations, otherwise it will not provide any increase in function. Finally, it must be inexpensive enough to be available to a large number of paraplegics. The primary aim of our work was to provide such a system to enable mid-thoracic lesion paraplegics to stand wherever they wish. This involved the development of a microprocessor-based stimulator to enable the stimulating envelope to be individually tailored to a given patient's requirements and the provision of closed loop control to minimize fatigue. A folding standing frame was also designed which replaces the arm rests on a standard wheelchair. Using this system, the user is able to stand within 30 //s of stopping and can remain standing for up to 10 min. Cosmetic calipers (knee-ankle-foot orothoses) are also being used for paraplegics who require to stand for longer periods.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [1] PRACTICAL CLOSED-LOOP STAND SIT AND WALKING SYSTEMS FOR MID THORACIC PARAPLEGICS
    EWINS, DJ
    TAYLOR, PN
    WHITLOCK, TL
    FOX, BA
    LIPCZYNSKI, RT
    SWAIN, ID
    ELECTROPHYSIOLOGICAL KINESIOLOGY /, 1988, 804 : 113 - 116
  • [2] A Feasible Low-Cost System for Kinematic and Kinetic Analysis of Sit-to-Stand Movement
    Wang, Daoyuan
    Tang, Yang
    Xu, Shengqian
    Wang, Yichong
    Yu, Jingtao
    Gu, Zenghui
    Ning, Gangmin
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2025, 147 (04):
  • [3] Low-cost, Automated Assessment of Sit-To-Stand Movement in "Natural" Environments
    Allin, Sonya
    Mihailidis, Alex
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 76 - 79
  • [4] Design of a low-cost, reconfigurable, standing wheelchair with easy and stable sit-stand-sit transition capability
    Sarda, Vivek
    Dash, Swostik Sourav
    Varma, D. S. Mohan
    Shaikh-Mohammed, Javeed
    Sujatha, S.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2023, 18 (07) : 1056 - 1065
  • [5] Development of Low-Cost Current Controlled Stimulator for Paraplegics
    Masdar, Aizan
    Ibrahim, B. S. K. K.
    Jamil, M. Mahadi Abdul
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2012, 4 (03): : 40 - 47
  • [6] LOW-COST STAND-ALONE GHOST CANCELLATION SYSTEM
    JOHNSON, L
    MCNAY, S
    HILL, R
    GREENE, D
    MANOR, Y
    HOROWITZ, S
    CASEY, R
    MURAKAMI, K
    KAKU, K
    KOO, D
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1994, 40 (03) : 632 - 639
  • [7] A LOW-COST FES EXERCISE BICYCLE FOR TRAINING PARAPLEGICS AT HOME
    MULDER, AJ
    HERMENS, HJ
    JANSSEN, F
    ZILVOLD, G
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1989, 13 (1-2) : 90 - 92
  • [8] PRACTICAL, LOW-COST, HOME-SCHOOL MICROPROCESSOR SYSTEM
    WEISBECKER, J
    COMPUTER, 1974, 7 (08) : 20 - 31
  • [9] Low-cost Laboratory Stand for Turbidity Measurements
    Makowski, Lukasz
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2016, 22 (01) : 49 - 52
  • [10] A practical guide to low-cost automation
    Curhan, Jeff
    Assembly, 2011, 54 (03): : 30 - 36