DETERMINATION OF URANYL-ION BY POTENTIOMETRIC TITRATION USING AN URANYL-SELECTIVE ELECTRODE

被引:6
|
作者
NASSORY, NS
机构
[1] Analytical Chemistry Department, Iraqi Atomic Energy Commission, Tuwaitha, Baghdad
来源
关键词
D O I
10.1007/BF00322215
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric titration of uranyl ion is described using an uranyl selective electrode based on a membrane containing a complex of UO2-bis[di-4-(1,1,3,3-tetra-methylbutyl)phenyl phosphate] as an ion-exchanger and tritolyl phosphate as a solvent mediator. The titrations were carried out with various titrants: sodium hydroxide, potassium fluoride and sodium salts of acetate, oxalate and citrate. The equivalence points were determined by Gran's method. Good results were obtained by using sodium oxalate as a titrant for the determination of uranium in several samples of ammonium diuranate. The results were quite comparable with those obtained by X-ray fluorescence spectrometry. © 1990 Springer-Verlag.
引用
收藏
页码:377 / 381
页数:5
相关论文
共 50 条
  • [1] DETERMINATION OF URANYL-ION BY POTENTIOMETRIC TITRATION USING URANYL SELECTIVE ELECTRODE
    NASSORY, NS
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 625 - 625
  • [2] URANYL-ION SELECTIVE ELECTRODE BASED ON A NEW SYNTHETIC NEUTRAL CARRIER
    SENKYR, J
    AMMANN, D
    MEIER, PC
    MORF, WE
    PRETSCH, E
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1979, 51 (07) : 786 - 790
  • [3] PHOTOCHEMISTRY OF URANYL-ION
    BURROWS, HD
    KEMP, TJ
    [J]. CHEMICAL SOCIETY REVIEWS, 1974, 3 (02) : 139 - 165
  • [4] INFLUENCE OF ION-EXCHANGER AND DILUENT STRUCTURE ON URANYL-ION SELECTIVE ELECTRODE RESPONSE
    GOLDBERG, I
    MEYERSTEIN, D
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2105 - 2108
  • [5] SPECTROPOLARIMETRIC TITRATION OF URANYL-ION WITH L-(-)-MALIC ACID
    CAMPI, E
    BAIOCCHI, C
    [J]. ANNALI DI CHIMICA, 1978, 68 (3-4) : 247 - 253
  • [6] PHOTOCHEMISTRY OF THE URANYL-ION IN SOLUTION
    ARVIS, M
    KELLER, N
    FOLCHER, G
    HICKEL, B
    [J]. JOURNAL OF PHOTOCHEMISTRY, 1981, 17 (1-2): : 146 - 147
  • [7] ANION COORDINATION TO URANYL-ION AND LUMINESCENCE LIFETIME OF URANYL COMPLEX
    MORIYASU, M
    YOKOYAMA, Y
    IKEDA, S
    [J]. JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1977, 39 (12): : 2199 - 2203
  • [8] EQUILIBRIUM STUDIES WITH THE URANYL-ION - NITROGEN BASES AND URANYL HEXAFLUOROACETYLACETONATES
    KRAMER, GM
    MAAS, ET
    DINES, MB
    [J]. INORGANIC CHEMISTRY, 1981, 20 (05) : 1418 - 1420
  • [9] A novel flow injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion
    Shamsipur, Mojtaba
    Mizani, Farhang
    Mousavi, Mir Fazlollah
    Alizadeh, Naader
    Alizadeh, Kamal
    Eshghi, Hossein
    Karami, Hassan
    [J]. ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 22 - 32
  • [10] MACROCYCLIC HEXACARBOXYLIC ACID - A HIGHLY SELECTIVE HOST FOR URANYL-ION
    TABUSHI, I
    KOBUKE, Y
    ANDO, K
    KISHIMOTO, M
    OHARA, E
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1980, 102 (18) : 5947 - 5948