QUANTITATIVE CHARACTERIZATION OF COLOR DOPPLER IMAGES - REPRODUCIBILITY, ACCURACY, AND LIMITATIONS

被引:47
|
作者
DELORME, S [1 ]
WEISSER, G [1 ]
ZUNA, I [1 ]
FEIN, M [1 ]
LORENZ, A [1 ]
VANKAICK, G [1 ]
机构
[1] GERMAN CANC RES CTR,DEPT RADIOL DIAGNOST & THERAPY,W-6900 HEIDELBERG,GERMANY
关键词
DOPPLER ULTRASONOGRAPHY; COMPUTER ASSISTED IMAGE ANALYSIS; BLOOD FLOW VELOCITIES;
D O I
10.1002/jcu.1870230906
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A computer-based quantitative analysis for color Doppler images of complex vascular formations is presented. The red-green-blue-signal from an Acuson XP10 is frame-grabbed and digitized. By matching each image pixel with the color bar, color pixels are identified and assigned to the corresponding flow velocity (color value). Data analysis consists of delineation of a region of interest and calculation of the relative number of color pixels in this region (color pixel density) as well as the mean color value. The mean color value was compared to flow velocities in a flow phantom. The thyroid and carotid artery in a volunteer were repeatedly examined by a single examiner to assess intra-observer variability. The thyroids in five healthy controls were examined by three experienced physicians to assess the extent of inter-observer variability and observer bias. The correlation between the mean color value and flow velocity ranged from 0.94 to 0.96 for a range of velocities determined by pulse repetition frequency. The average deviation of the mean color value from the flow velocity was 22% to 41%, depending on the selected pulse repetition frequency (range of deviations, - 46% to + 66%). Flow velocity was underestimated with inadequately low pulse repetition frequency, or inadequately high reject threshold. An overestimation occurred with inadequately high pulse repetition frequency. The highest intra-observer variability was 22% (relative standard deviation) for the color pixel density, and 9.1% for the mean color value. The inter-observer variation was approximately 30% for the color pixel density, and 20% for the mean color value. In conclusion, computer assisted image analysis permits an objective description of color Doppler images. However, the user must be aware that image acquisition under in vivo conditions as well as physical and instrumental factors may considerably influence the results. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:537 / 550
页数:14
相关论文
共 50 条
  • [1] LIMITATIONS OF COLOR DOPPLER IN QUANTITATIVE ASSESSMENT OF MITRAL REGURGITATION
    SAENZ, CB
    DEUMITE, NJ
    ROITMAN, DI
    MOOS, S
    NANDA, NC
    SOTO, B
    [J]. CIRCULATION, 1985, 72 (04) : 99 - 99
  • [2] QUANTITATIVE FLOW MEASUREMENTS WITH DOPPLER ULTRASOUND - TECHNIQUES, ACCURACY, AND LIMITATIONS
    BURNS, PN
    JAFFE, CC
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 1985, 23 (04) : 641 - 657
  • [3] Reproducibility of color Doppler imaging
    Ingeborg Stalmans
    Brent Siesky
    Thierry Zeyen
    Steffen Fieuws
    Alon Harris
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1531 - 1538
  • [4] Reproducibility of color Doppler imaging
    Stalmans, Ingeborg
    Siesky, Brent
    Zeyen, Thierry
    Fieuws, Steffen
    Harris, Alon
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (11) : 1531 - 1538
  • [5] Accuracy of Ultrasonography With Color Doppler in Ovarian Tumor A Systematic Quantitative Review
    Medeiros, Lidia Rosi
    Rosa, Daniela Dornelles
    da Rosa, Maria Ines
    Bozzetti, Mary Clarisse
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2009, 19 (02) : 230 - 236
  • [6] Accuracy of Ultrasonography With Color Doppler in Ovarian Tumor A Systematic Quantitative Review
    Medeiros, Lidia Rosi
    Rosa, Daniela Dornelles
    da Rosa, Maria Ines
    Bozzetti, Mary Clarisse
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2009, 19 (07) : 1214 - 1220
  • [7] Quantitative contrast-enhanced color power Doppler ultrasound: Accuracy in vivo
    Blomley, MJ
    Albrecht, T
    Jayaram, V
    Cosgrove, DO
    Bell, D
    Bamber, JC
    [J]. RADIOLOGY, 1997, 205 : 1173 - 1173
  • [8] Reproducibility of color Doppler imaging in orbital vessels
    Senn, BC
    Kaiser, HJ
    Schotzau, A
    Flammer, J
    [J]. GERMAN JOURNAL OF OPHTHALMOLOGY, 1997, 5 (06) : 386 - 391
  • [9] ACCURACY AND REPRODUCIBILITY OF A QUANTITATIVE LIPOPROTEIN ELECTROPHORESIS
    BOJANOVSKI, D
    WIPPERMANN, B
    CANZLER, H
    [J]. JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 620 - 620
  • [10] INTERNAL CAROTID-ARTERY STENOSIS - ACCURACY AND REPRODUCIBILITY OF COLOR-DOPPLER-ASSISTED DUPLEX IMAGING
    POLAK, JF
    DOBKIN, GR
    OLEARY, DH
    WANG, AM
    CUTLER, SS
    [J]. RADIOLOGY, 1989, 173 (03) : 793 - 798