COMPARISON OF 2 METHODS OF MECHANICAL DISAGGREGATION OF SCIRRHOUS BREAST ADENOCARCINOMAS FOR DNA FLOW CYTOMETRIC ANALYSIS OF WHOLE CELLS

被引:4
|
作者
TORRES, FX
MACKOWIAK, PG
BROWN, RD
LINDEN, MD
ZARBO, RJ
机构
[1] Division of Surgical Pathology, Henry Ford Hospital
关键词
FLOW CYTOMETRY; COEFFICIENT OF VARIATION; DNA PLOIDY; S-PHASE FRACTION; CELL DISAGGREGATION; BREAST CARCINOMA;
D O I
10.1093/ajcp/103.1.8
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Mechanical release of single cell suspensions from solid tumors for DNA analysis by flow cytometry has been shown to be optimal for adenocarcinomas in general, In the breast, many adenocarcinomas are fibrotic or scirrhous, creating difficulty in separating the neoplastic cells from the stroma, The authors have conducted a parallel study in 20 consecutive cases of scirrhous adenocarcinomas of the breast using two mechanical methods of cell disaggregation by: (1) mincing tumor tissue in culture media (MINCE); and (2) scraping the surface of the solid tumor with a scalpel blade and rinsing the blade in culture media (SCRAPE), Both methods were compared with PI staining and quantitation of percent debris and coefficient of variation (CV), as an index of resolution of the G(0)/G(1) tumor peak, Debris was quantitated using Cell-FIT (Becton Dickinson Immunocytometry Systems, San Jose, CA) and Multicycle (Phoenix Flow Systems, San Diego, CA) software programs, With Multicycle, in addition to debris and aggregate determination, an index that included background, aggregates and debris (%BAD) occurring between the boundaries of the tumor G(1) and G(2) region was evaluated, In the 4 DNA diploid and 16 DNA aneuploid tumors, there was no significant difference in histogram quality measured by CV or amount of debris, aggregates, and %BAD between MINCE and SCRAPE methods. The authors conclude that either method of mechanical disaggregation will produce DNA histograms of comparable quality and degree of resolution, However, the scrape method may be advantageous in the mechanical disaggregation in scirrhous tumors, The scrape method also may be useful in small tumors, where tissue preservation for histology is paramount, and there is insufficient material to separately submit for flow cytometry. Combination of both MINCE and SCRAPE may provide higher cell yields, than using only one of these dissociation techniques. In addition, DNA analysis methods using intact cells obtained with the SCRAPE method result in percent CV values of similar resolution to those reported for methods producing bare nuclear suspensions from fresh tumors.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [1] COMPARISON OF 2 METHODS OF MECHANICAL DISAGGREGATION OF BREAST ADENOCARCINOMAS FOR DNA FLOW CYTOMETRIC ANALYSIS OF INTACT-CELLS
    TORRES, FX
    MACKOWIAK, PG
    BROWN, RD
    LINDEN, MD
    ZARBO, RJ
    LABORATORY INVESTIGATION, 1992, 66 (01) : A121 - A121
  • [2] Tissue disaggregation for flow cytometric DNA analysis: Comparison of fine-needle aspiration and an automated mechanical procedure
    Ottesen, GL
    Christensen, IJ
    Larsen, JK
    Hansen, B
    Andersen, JA
    CYTOMETRY, 1996, 26 (01): : 65 - 68
  • [3] FLOW CYTOMETRIC DNA ANALYSIS OF ADENOCARCINOMAS OF THE VERMIFORM APPENDIX
    NIELSEN, GP
    JONASSON, JG
    AGNARSSON, BA
    ISAKSSON, HJ
    APMIS, 1993, 101 (10) : 811 - 814
  • [4] THE RELIABILITY OF MICROSPECTROPHOTOMETRIC AND FLOW CYTOMETRIC NUCLEAR-DNA MEASUREMENTS IN ADENOCARCINOMAS OF THE BREAST
    FALLENIUS, AG
    ASKENSTEN, UG
    SKOOG, LK
    AUER, GU
    CYTOMETRY, 1987, 8 (03): : 260 - 266
  • [5] FLOW CYTOMETRIC DNA ANALYSIS IN BREAST CARCINOMAS
    CHASSEVENT, A
    SPYRATOS, F
    BULLETIN DU CANCER, 1989, 76 (02) : 153 - 164
  • [6] FLOW CYTOMETRIC DNA ANALYSIS IN THE DIAGNOSIS OF LUNG-TUMORS - A COMPARISON WITH CONVENTIONAL METHODS
    CHRETIEN, MF
    CHASSEVENT, A
    MALKANI, K
    REBEL, A
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1988, 10 (04): : 251 - 255
  • [7] FLOW CYTOMETRIC DNA ANALYSIS OF COLON ADENOCARCINOMAS - A COMPARATIVE-STUDY OF PREPARATORY TECHNIQUES
    CRISSMAN, JD
    ZARBO, RJ
    NIEBYLSKI, CD
    CORBETT, T
    WEAVER, D
    MODERN PATHOLOGY, 1988, 1 (03) : 198 - 204
  • [8] FLOW CYTOMETRIC ANALYSIS OF DENDRITIC CELLS IN WHOLE-BLOOD
    MACEY, MG
    MCCARTHY, DA
    BROWNK, A
    KNIGHT, SC
    NEWLAND, AC
    PATHOLOGIE BIOLOGIE, 1994, 42 (08): : 807 - 807
  • [9] LACK OF PROGNOSTIC VALUE OF FLOW CYTOMETRIC DNA CONTENT-ANALYSIS IN COLORECTAL ADENOCARCINOMAS
    SCIALLERO, S
    BONELLI, L
    GEIDO, E
    LETTIERI, L
    ZERASCHI, E
    BRUZZI, P
    ASTE, H
    GIARETTI, W
    EUROPEAN JOURNAL OF CANCER, 1994, 30A (04) : 569 - 569
  • [10] FLOW CYTOMETRIC DNA ANALYSIS OF HUMAN-BREAST TUMORS AND COMPARISON WITH CLINICAL AND PATHOLOGIC PARAMETERS
    MORAN, RE
    STRAUS, MJ
    BLACK, MM
    ALVAREZ, EM
    EVANS, MD
    EVANS, RA
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1982, 23 (MAR): : 33 - 33