DESCRIPTION AND VALIDATION OF A FLOW-CYTOMETRIC METHOD TO ESTIMATE WHITE BLOOD-CELL COUNTS IN LEUKOCYTE-DEPLETED RED-CELL CONCENTRATES

被引:6
|
作者
LAMBREY, Y [1 ]
CREUZENET, C [1 ]
BOUGY, F [1 ]
COHEN, JHM [1 ]
BIGGIO, B [1 ]
机构
[1] HOP ROBERT DEBRE,DROPSY LAB,REIMS,FRANCE
来源
关键词
D O I
10.1016/S1140-4639(05)80240-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We describe a flow-cytometric method for estimating residual white blood cells (WBC) counts in WBC depleted blood components, namely units of packed red cells. The method uses fluorescent staining of nuclear ADN with ethidium bromide. WBC nuclei are discriminated from background events using fluorescence ratio (585 nm versus 650 nm). A facultative procedure of concentration is described, in order to get better sensitivity at very low WBC counts. Main steps of validation are dilution assays and correlation with hemocytometer counts. The method can be used to explore very low concentrations (less than 100 WBC/ml) and should be useful in quality control of blood products.
引用
收藏
页码:375 / 390
页数:16
相关论文
共 50 条
  • [1] A flow-cytometric method for assessing leukocyte contamination in white-cell-depleted blood products
    Andea, A
    Garritsen, HSP
    Cassens, U
    Kelsch, R
    Sibrowksi, W
    [J]. INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1999, 26 (01): : 53 - 56
  • [2] TRANSFUSION OF LEUKOCYTE-DEPLETED RED-CELL CONCENTRATES AND WHOLE-BLOOD WITH A NEW BEDSIDE FILTER SYSTEM
    BOCK, M
    KRAUSE, C
    WAGNER, M
    HEIM, MU
    BRAUN, S
    PACHMANN, U
    MEMPEL, W
    [J]. PLASMA THERAPY & TRANSFUSION TECHNOLOGY, 1987, 8 (04): : 302 - 306
  • [3] Cytokine generation in whole blood, leukocyte-depleted and temporarily warmed red blood cell concentrates
    Weisbach, V
    Wanke, C
    Zingsem, J
    Zimmermann, R
    Eckstein, R
    [J]. VOX SANGUINIS, 1999, 76 (02) : 100 - 106
  • [4] FLOW-CYTOMETRIC LIGHT-SCATTERING MEASUREMENT OF RED BLOOD-CELL VOLUME AND HEMOGLOBIN CONCENTRATION
    TYCKO, DH
    METZ, MH
    EPSTEIN, EA
    GRINBAUM, A
    [J]. APPLIED OPTICS, 1985, 24 (09): : 1355 - 1365
  • [5] A FLOW CYTOMETRIC TECHNIQUE TO ACCURATELY MEASURE POST-FILTRATION WHITE BLOOD-CELL COUNTS
    BODENSTEINER, DC
    [J]. TRANSFUSION, 1989, 29 (07) : 651 - 653
  • [6] LEUKOCYTE DEPLETION OF RED-CELL CONCENTRATES BY FILTRATION - INFLUENCE OF BLOOD PRODUCT TEMPERATURE
    BEAUJEAN, F
    SEGIER, JM
    LEFORESTIER, C
    DUEDARI, N
    [J]. VOX SANGUINIS, 1992, 62 (04) : 242 - 243
  • [7] A simple flow-cytometric method for absolute counting of residual white blood cells in leukocyte-reduced packed red cells
    Gómez-Arbonés, X
    Pinacho, A
    Ortiz, P
    Maciá, J
    Gallart, M
    Araguás, C
    Sánchez, JM
    Teixidó, M
    [J]. VOX SANGUINIS, 1999, 76 (01) : 64 - 65
  • [8] The influence of washing on the quality of pre storage leukocyte depleted red blood cell concentrates
    Weisbach, V
    Riego, W
    Strasser, E
    Zingsem, J
    Eckstein, R
    [J]. TRANSFUSION, 2003, 43 (09) : 69A - 69A
  • [9] FLOW CYTOMETRY FOR WHITE BLOOD-CELL COUNTS IN WHOLE-BLOOD AND BLOOD COMPONENTS
    RADTKE, H
    LINDENAU, S
    HOLBACH, B
    NEUMANN, S
    KIESEWETTER, H
    [J]. INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 1995, 22 : 112 - 114
  • [10] FLOW CYTOMETRIC ANALYSIS OF RESIDUAL WHITE BLOOD-CELL CONCENTRATION AND PLATELET ACTIVATION ANTIGENS IN DOUBLE FILTERED PLATELET CONCENTRATES
    LOMBARDO, JF
    CUSACK, NA
    RAJAGOPALAN, C
    SANGALINE, RJ
    AMBRUSO, DR
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1993, 122 (05): : 557 - 566