A LASER VAPORIZATION, LASER IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER FOR THE PROBING OF FRAGILE BIOMOLECULES

被引:12
|
作者
SCHILKE, DE
LEVIS, RJ
机构
[1] Department of Chemistry, Wayne State University, Detroit
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1994年 / 65卷 / 06期
关键词
D O I
10.1063/1.1144841
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the design and evaluation of a new spectrometer for probing fragile biomolecules in the gas phase. The spectrometer is based on a laser vaporization method to transfer biomolecules up to several hundred thousand dalton into the gas phase as intact, neutral species. This method requires the formation of a thin film containing a dye molecule and the analyte of interest which is molecularly vaporized using a high energy, pulsed laser. The gas phase, neutral analyte molecules are laser vaporized directly into a laser ionization region without the need of a pulsed nozzle. The molecules are subsequently ionized using multiphoton ionization; two-color, two-photon laser ionization is reported here. The resulting ions are detected using time-of-flight mass spectrometry. The spectrometer employs a four grid extraction system which both filters unwanted ions produced in the initial vaporization step and extracts the laser ionized species into the field free drift region. A hybrid copper-beryllium dynode with a dual microchannel plate detector is employed as the high mass ion detector and amplifier before external amplification. Anthracene-tagged nucleotides and some small test molecules are vaporized and ionized to evaluate the spectrometer.
引用
收藏
页码:1903 / 1911
页数:9
相关论文
共 50 条
  • [1] AN IMPROVED LASER VAPORIZATION CLUSTER SOURCE AND TIME-OF-FLIGHT MASS-SPECTROMETER
    DEHEER, WA
    MILANI, P
    [J]. ZEITSCHRIFT FUR PHYSIK D-ATOMS MOLECULES AND CLUSTERS, 1991, 20 (1-4): : 437 - 439
  • [2] MASS RESOLUTION OF 10000 IN A LASER IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER
    WALTER, K
    BOESL, U
    SCHLAG, EW
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 71 (03): : 309 - 313
  • [3] A HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER WITH LASER DESORPTION AND A LASER IONIZATION SOURCE
    BOESL, U
    GROTEMEYER, J
    WALTER, K
    SCHLAG, EW
    [J]. ANALYTICAL INSTRUMENTATION, 1987, 16 (01): : 151 - 171
  • [4] LASER-INDUCED SURFACE-IONIZATION IN A TIME-OF-FLIGHT MASS-SPECTROMETER
    SCHRIEMER, DC
    LI, L
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 55 - 62
  • [5] REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER FOR LASER PHOTODISSOCIATION
    CORNETT, DS
    PESCHKE, M
    LAIHING, K
    CHENG, PY
    WILLEY, KF
    DUNCAN, MA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2177 - 2186
  • [6] LASER-DRIVEN ELECTRON IONIZATION FOR A VUV PHOTOIONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER
    BOYLE, JG
    PFEFFERLE, LD
    GULCICEK, EE
    COLSON, SD
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (02): : 323 - 333
  • [7] A MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETER
    CHAKEL, L
    [J]. AMERICAN LABORATORY, 1994, 26 (14) : C32 - E32
  • [8] A HIGH-RESOLUTION TIME-OF-FLIGHT MASS-SPECTROMETER USING LASER RESONANCE IONIZATION
    FREY, R
    WEISS, G
    KAMINSKI, H
    SCHLAG, EW
    [J]. ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1985, 40 (12): : 1349 - 1350
  • [9] LASER PHOTODISSOCIATION OF IONS IN A BENDIX TIME-OF-FLIGHT MASS-SPECTROMETER
    DUNBAR, RC
    ARMENTROUT, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1977, 24 (04): : 465 - 468
  • [10] LASER-INDUCED ELECTRON-IMPACT IONIZATION IN A REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    MORITZ, F
    DEY, M
    ZIPPERER, K
    PRINKE, S
    GROTEMEYER, J
    [J]. ORGANIC MASS SPECTROMETRY, 1993, 28 (12): : 1467 - 1475