EXPERIMENTAL-ANALYSIS OF SAPPHIRE CONTACT PROBES FOR ND-YAG LASER ANGIOPLASTY

被引:0
|
作者
ASHLEY, S [1 ]
BROOKS, SG [1 ]
GEHANI, AA [1 ]
KESTER, RC [1 ]
REES, MR [1 ]
机构
[1] ST JAMES UNIV HOSP,DEPT VASC SURG,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
关键词
D O I
10.1177/000331979004100606
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Laser angioplasty may offer percutaneous recanalization of occluded vessels where conventional guidewire and balloon techniques fail. Metal laser thermal angioplasty probes may, however, cause excessive thermal damage due to high tip temperatures (>400.C). Therefore, contact probes made from artificial sapphire crystal designed for general laser surgery are currently being evaluated for use in laser angioplasty with continuous wave Nd-YAG energy. The sapphire modifies the laser energy in various ways, and this paper examines the physical characteristics of five types of rounded sapphire probe (SMTR, MTR, MTRL, OS, LT) and how these properties are affected by clinical usage. The laser beam profile emitted by these probes demonstrates a focal spot 1-2 mm in front of the tip. However, the forward transmission of Nd-YAG energy through the sapphires varied (SMTR, 85%; MTR, 83%; MTRL, 75%; OS, 54%; LT, 69%). Probe heating occurs owing to energy absorption within the sapphire. The surface temperature of the sapphires was measured in air by infrared thermography and the hottest region within the probes localized by an isothermographic technique. At energy settings used clinically (20 J, 10 watts for 2 s) the SMTR, MTR, and MTRL probes exhibited higher temperature rises (94-112.C) than the OS and LT probes (30.C), and heating was localized to the front surface of the former probes. Peak sapphire temperatures remained lower than those of metal probes even at higher energies. After clinical use, the MTR probe demonstrated reduced transmission, beam defocusing, and increased heating, due to surface pitting. Thus, recanalization with sapphire probes occurs by a combination of photothermal and contact thermal effects that are localized to the probe tip and may reduce the degree of thermal injury associated with metal probes. Understanding these basic properties is important to the application and development of contact probes for laser recanalization. © 1990, Sage Publications. All rights reserved.
引用
收藏
页码:453 / 462
页数:10
相关论文
共 50 条
  • [1] ND-YAG LASER IRRADIATION OF AN EYE MODEL - EXPERIMENTAL-ANALYSIS
    DOCCHIO, F
    SACCHI, CA
    [J]. LASERS IN SURGERY AND MEDICINE, 1987, 6 (06) : 520 - 529
  • [2] CONTACT TIP PROBES USED WITH THE 1060 ND-YAG LASER
    PENNINO, R
    LOWE, B
    PADILLA, S
    GOGEL, H
    [J]. LASERS IN SURGERY AND MEDICINE, 1988, 8 (02) : 143 - 143
  • [3] ND-YAG LASER ANNEALING OF SILICON ON SAPPHIRE
    AFFOLTER, K
    LUTHY, W
    ROULET, ME
    SCHWOB, P
    FALLAVIER, M
    THOMAS, JP
    MACKOWSKI, JM
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (08) : C364 - C364
  • [4] ARTIFICIAL SAPPHIRE PROBE FOR CONTACT PHOTOCOAGULATION AND TISSUE VAPORIZATION WITH THE ND-YAG LASER
    DAIKUZONO, N
    JOFFE, SN
    [J]. MEDICAL INSTRUMENTATION, 1985, 19 (04): : 173 - 178
  • [5] ARTIFICIAL SAPPHIRE CONTACT ENDOPROBE WITH ND-YAG LASER IN THE TREATMENT OF SUBGLOTTIC STENOSIS
    MEHTA, AC
    LIVINGSTON, DR
    GOLISH, JA
    [J]. CHEST, 1987, 91 (03) : 473 - 474
  • [6] BREAKAGE OF ND-YAG LASER SAPPHIRE CONTACT PROBE INSIDE THE ENDOBRONCHIAL TREE
    MEHTA, AC
    GRIMM, M
    [J]. CHEST, 1988, 93 (05) : 1119 - 1119
  • [7] CONDITIONS FOR EFFECTIVE ND-YAG LASER ANGIOPLASTY
    GESCHWIND, HJ
    BOUSSIGNAC, G
    TEISSEIRE, B
    BENHAIEM, N
    BITTOUN, R
    LAURENT, D
    [J]. BRITISH HEART JOURNAL, 1984, 52 (05): : 484 - 489
  • [8] ND-YAG ILIAC AND FEMOROPOPLITEAL LASER ANGIOPLASTY - RESULTS WITH LARGE PROBES AS SOLE THERAPY
    ROSENTHAL, D
    WHEELER, WG
    SEAGRAVES, A
    ERDOES, L
    LAMIS, PA
    JONES, M
    CLARK, MD
    PALLOS, LL
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1991, 32 (02): : 186 - 191
  • [9] CHARACTERISTICS OF ND-YAG SCULPTURED CONTACT PROBES AFTER PROLONGED LASER APPLICATION
    BARROSO, EG
    HAKLIN, MF
    STAREN, ED
    [J]. LASERS IN SURGERY AND MEDICINE, 1995, 16 (01) : 76 - 80
  • [10] RECRYSTALLIZATION OF SILICON FILMS ON SAPPHIRE WITH AN ND-YAG LASER
    AFFOLTER, K
    LUTHY, W
    ROULET, ME
    [J]. HELVETICA PHYSICA ACTA, 1980, 53 (02): : 278 - 278