Treatment of C2 body fracture with unusual distractive and rotational components resulting in gross instability

被引:3
|
作者
Lau, Darryl [1 ]
Shin, Samuel S. [2 ]
Patel, Rakesh [3 ]
Park, Paul [1 ]
机构
[1] Univ Michigan, Dept Neurosurg, 1500 E Med Ctr Dr,Room 3552 TC, Ann Arbor, MI 48109 USA
[2] Univ Pittsburgh, Dept Neurol Surg, Pittsburgh, PA 15213 USA
[3] Univ Michigan, Dept Orthoped Surg, Ann Arbor, MI 48109 USA
来源
WORLD JOURNAL OF ORTHOPEDICS | 2013年 / 4卷 / 04期
关键词
C2; Distractive; Odontoid fracture; Rotational; Spine; Type; Unstable;
D O I
10.5312/wjo.v4.i4.323
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cervical fractures can result in severe neurological compromise and even death. One of the most commonly injured segments is the C2 vertebrae, which most frequently involves the odontoid process. In this report, we present the unusual case of a 28-year-old female who sustained a C2 vertebral body fracture (comminuted transverse fracture through the body and both transverse processes) that had both a significant distractive and rotational component, causing the fracture to be highly unstable. Application of halo bracing was unsuccessful. The patient subsequently required a C1-C4 posterior spinal fusion. Follow-up computer tomography imaging confirmed fusion and the patient did well clinically thereafter. (C) 2013 Baishideng. All rights reserved.
引用
收藏
页码:323 / 326
页数:4
相关论文
共 43 条
  • [1] Sagittal fracture of C2 body: One case report
    Tabib, W
    Sayegh, S
    Betina, K
    Moysan, P
    Meyer, M
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (08): : 731 - 735
  • [2] ELECTRONIC CIGARETTE EXPLOSION RESULTING IN A C1 AND C2 FRACTURE: A CASE REPORT
    Norii, Tatsuya
    Plate, Adam
    JOURNAL OF EMERGENCY MEDICINE, 2017, 52 (01): : 86 - 88
  • [3] Transoral vertebral augmentation with polymethylmethacrylate in the treatment of a patient with a dens fracture nonunion and subarticular vertebral body fracture of C2
    Beall, Douglas P.
    Stanfield, Matthew
    Martin, Hal D.
    Stapp, Annette M.
    SKELETAL RADIOLOGY, 2007, 36 (05) : 453 - 458
  • [4] Transoral vertebral augmentation with polymethylmethacrylate in the treatment of a patient with a dens fracture nonunion and subarticular vertebral body fracture of C2
    Douglas P. Beall
    Matthew Stanfield
    Hal D. Martin
    Annette M. Stapp
    Skeletal Radiology, 2007, 36 : 453 - 458
  • [5] Direct C2 Pedicle Screw Fixation for Axis Body Fracture
    Reynolds, Jennifer A.
    MacDonald, Joel D.
    WORLD NEUROSURGERY, 2016, 93 : 279 - 285
  • [6] C2/3 instability: unusual cause of cervical myelopathy in a child with Down syndrome
    Al-Habib, Amro
    AlAqeel, Ahmed
    CHILDS NERVOUS SYSTEM, 2013, 29 (01) : 163 - 165
  • [7] C2/3 instability: unusual cause of cervical myelopathy in a child with Down syndrome
    Amro Al-Habib
    Ahmed AlAqeel
    Child's Nervous System, 2013, 29 : 163 - 165
  • [8] C2 Body Fracture: Report of Cases Managed Conservatively by Philadelphia Collar
    Motiei-Langroudi, Rouzbeh
    Sadeghian, Homa
    ASIAN SPINE JOURNAL, 2016, 10 (05) : 920 - 924
  • [9] CT APPEARANCE OF AN UNUSUAL TYPE OF COMMINUTED FRACTURE-DISLOCATION OF C1 AND C2
    TASDEMIROGLU, E
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1994, 113 (02) : 113 - 114
  • [10] C1-C2 Wiring With Timed Self-Obsolescence for Complex C2 Body Fracture
    Wroe, William W.
    Budde, Bradley
    Hsieh, Joseph C.
    OPERATIVE NEUROSURGERY, 2021, 21 (03) : E278 - E282