ANALYSIS OF POWDER MIXTURES WITH THE HELP OF ABRASIVE STRIPPING VOLTAMMETRY AND COULOMETRY

被引:38
|
作者
SCHOLZ, F [1 ]
LANGE, B [1 ]
JAWORSKI, A [1 ]
PELZER, J [1 ]
机构
[1] BUNDESANSTALT GEWASSERKUNDE,O-1190 BERLIN,GERMANY
来源
关键词
D O I
10.1007/BF00324469
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Abrasive stripping voltammetry was applied to the quantitative analysis of the following powder mixtures: MnO2-FeOOH, HgS-HgO, HgO-PbO. Therefore, mu-g-amounts of the powder mixture were transferred onto a solid electrode and the electrochemical response of the solid sample is recorded. The calibration was made by measuring the percentage peak height of each component taking the sum of peak currents of both components as 100%. The relative standard deviation ranges from 3 to 15%. A calibration-free method based on microcoulometric measurements can be used in the case of powder mixtures of AgCl-AgI. The integration of staircase voltammograms directly yields the charges required to reduce AgCl and AgI and thus also gives the ratio of both components. The relative standard deviation was almost-equal-to 10%. Microcoulometric measurements gave evidence that, in abrasive stripping voltammetry, the amount of electroactive substance ranges between 10(-12) and 10(-9) mole.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [1] Abrasive stripping voltammetry analysis of dental alloys.
    Müller, WD
    Schenk, AR
    Scholz, F
    Lange, KP
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B256 - B256
  • [2] STRIPPING VOLTAMMETRY AND COULOMETRY OF LEAD ON A CARBON PYROCERAMIC ELECTRODE
    KABANOVA, OL
    GONCHAROV, YA
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1976, 31 (05): : 734 - 738
  • [3] Abrasive stripping voltammetry of myricetin and dihydromyricetin
    Komorsky-Lovric, Sebojka
    Novak, Ivana
    [J]. ELECTROCHIMICA ACTA, 2013, 98 : 153 - 156
  • [4] Abrasive stripping voltammetry at polycrystalline diamond electrodes
    Manivannan, A
    Tryk, DA
    Fujishima, A
    [J]. CHEMISTRY LETTERS, 1999, (09) : 851 - 852
  • [5] HIGH-PERFORMANCE ABRASIVE STRIPPING VOLTAMMETRY
    SCHOLZ, F
    LANGE, B
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (03): : 293 - 294
  • [6] ELECTROCHEMICAL DISSOLUTION OF GOETHITE BY ABRASIVE STRIPPING VOLTAMMETRY
    GRYGAR, T
    SUBRT, J
    BOHACEK, J
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1995, 60 (06) : 950 - 959
  • [7] Solid state electrochemical studies of mixed nickel-iron hexacyanoferrates with the help of abrasive stripping voltammetry
    Reddy, SJ
    Dostal, A
    Scholz, F
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 403 (1-2): : 209 - 212
  • [8] Abrasive Stripping Voltammetry and ESR Spectroscopy of Manganese in Carbonates
    Komorsky-Lovric, S.
    Bartoll, J.
    Stoesser, R.
    Scholz, F.
    [J]. Croatia Chimica Acta, 1997, 70 (02):
  • [9] Abrasive Stripping Voltammetry in Room Temperature Ionic Liquids
    Chen, Aicheng
    Rogers, Emma I.
    Compton, Richard G.
    [J]. ELECTROANALYSIS, 2009, 21 (01) : 29 - 35
  • [10] Abrasive stripping voltammetry and ESR spectroscopy of manganese in carbonates
    KomorskyLovric, S
    Bartoll, J
    Stosser, R
    Scholz, F
    [J]. CROATICA CHEMICA ACTA, 1997, 70 (02) : 563 - 583