RESPIRATORY BLUR IN 3D CORONARY MR-IMAGING

被引:49
|
作者
WANG, Y [1 ]
GRIST, TM [1 ]
KOROSEC, FR [1 ]
CHRISTY, PS [1 ]
ALLEY, MT [1 ]
POLZIN, JA [1 ]
MISTRETTA, CA [1 ]
机构
[1] UNIV WISCONSIN,MADISON,WI
关键词
CORONARY ANGIOGRAPHY; MAGNETIC RESONANCE IMAGING; RESPIRATORY MOTION; IMAGE BLUR AND GHOSTS;
D O I
10.1002/mrm.1910330413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
3D MR imaging of coronary arteries has the potential to provide both high resolution and high signal-to-noise ratio, but it is very susceptible to respiratory artifacts, especially respiratory blurring. Resolution loss caused by respiratory blurring in 3D coronary imaging is analyzed theoretically and verified experimentally. Under normal respiration, the width for any Gaussian point spread function is increased to a new value that is at least several millimeters (about 3-4 mm). In vivo studies were performed to compare respiratory pseudo-gated 3D acquisition with breath-hold 2D acquisition. On average, the overall quality of a pseudo-gated 3D image is worse than that of the corresponding breath-hold 2D image (P = 0.00). In most cases, respiratory blur caused coronary arteries in pseudo-gated 3D data to have lower resolution than in breath-hold 2D data.
引用
收藏
页码:541 / 548
页数:8
相关论文
共 50 条
  • [1] DIAGNOSIS OF ACOUSTIC NEUROMAS WITH 3D FAST SE MR-IMAGING
    SOULIE, D
    CORDOLIANI, Y
    SARRAZIN, J
    DEROSIER, C
    VIGNAUD, J
    COSNARD, G
    [J]. RADIOLOGY, 1995, 197 : 135 - 135
  • [2] 3D MR imaging of coronary arteriovenous fistulas
    Duerinckx, AJ
    Shaaban, A
    Lewis, A
    Perloff, J
    Laks, H
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (09) : 1459 - 1463
  • [3] 3D MR imaging of coronary arteriovenous fistulas
    A. J. Duerinckx
    A. Shaaban
    A. Lewis
    J. Perloff
    H. Laks
    [J]. European Radiology, 2000, 10 : 1459 - 1463
  • [4] INTERPRETATION MODEL FOR HIGH-RESOLUTION 3D BREAST MR-IMAGING
    SCHNALL, MD
    NUNES, LW
    HOCHMAN, MG
    OREL, SG
    POWELL, CM
    [J]. RADIOLOGY, 1995, 197 : 129 - 129
  • [5] CT SCANNING AND MR-IMAGING TECHNIQUES FOR 3D MODELING OF THE TRAPEZIOMETACARPAL JOINT
    LBATHLASSAYS, F
    RUMELHART, C
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C55 - C55
  • [6] Improved 3D spiral imaging for coronary MR angiography
    Börnert, P
    Aldefeld, B
    Nehrke, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (01) : 172 - 175
  • [7] 3D colonic MR-imaging (CMRI): Preliminary experience in the assessment of colonic pathologies
    Bauerfeind, P
    Luboldt, W
    Schoenenberger, A
    Steiner, P
    Krestin, GP
    Fried, M
    Debatin, JF
    [J]. GASTROENTEROLOGY, 1997, 112 (04) : A537 - A537
  • [8] Comparison of breath-hold 3D and retrospectively respiratory gated 3D MR coronary angiography with conventional coronary arteriography
    Wielopolski, PA
    VanGuens, RJ
    DeFeijter, PJ
    DeBruin, HG
    Bongaerts, AH
    Oudkerk, M
    [J]. RADIOLOGY, 1997, 205 : 59 - 59
  • [9] RAPID AUTOMATIC BRAIN VOLUMETRY ON THE BASIS OF MULTISPECTRAL 3D MR-IMAGING DATA ON PERSONAL COMPUTERS
    FRIEDLINGER, M
    SCHAD, LR
    BLUML, S
    TRITSCH, B
    LORENZ, WJ
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (02) : 185 - 205
  • [10] QUANTIFICATION OF SYNOVIAL LINING VOLUME IN CHRONIC SYNOVITIS WITH CONTRAST-ENHANCED 3D MR-IMAGING
    CLUNIE, GP
    HALLCRAGGS, MA
    PALEY, M
    ELL, PJ
    EDWARDS, JC
    [J]. RADIOLOGY, 1995, 197 : 265 - 265