BODY-FAT ESTIMATIONS BY ELECTRICAL-IMPEDANCE AND INFRARED INTERACTANCE

被引:11
|
作者
BRODIE, DA
ESTON, RG
机构
[1] Dept. of Movement Sci./Phys. Educ., Liverpool University, Liverpool L69 3BX
关键词
BODY FAT; IMPEDANCE; HYDROSTATIC WEIGHING;
D O I
10.1055/s-2007-1021274
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to examine body fat estimation using three methods of electrical impedance (the BIA-103 Body Composition Analyser - RJL Systems, Detroit; the BMR 2000 Body Composition Analyzer - Berkeley Medical Research, San Leandro; the BC300 Body Composition Analyzer - Spacelabs, Dallas) and an infra-red interactance method (Futrex 5000 Analyzer - Futrex Inc. Gaithersburg) as an alternative to hydrodensitometry. Five different groups were examined using at least one of the electrical systems and in all cases utilising hydrodensitometry as the criterion method. The results produced highly significant correlations between all methods, but caution is recommended due to the limited common variance in some cases. The individual electrical methods differed from hydrodensitometry by a maximum of 1.1 % in obese women, by 21.6 % in athletic adults, by 6.2 % in the slightly obese group, by 8.1 % in normal women and by 56.0% in normal children. Significant mean differences between one of the impedance methods and hydrodensitometry were only noted in two of the groups tested. This suggests, allowing for the limitations of hydrodensitometry itself, that the other three electrical methods appear to be reasonably valid alternatives to underwater weighing, especially for field work of an epidemiological nature.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 50 条
  • [1] A COMPARISON OF THE ASSESSMENT OF BODY-FAT BY OBESITY INDEXES AND ELECTRICAL-IMPEDANCE
    CARTMEL, B
    LOHMAN, T
    MOON, T
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1991, 134 (07) : 733 - 733
  • [2] BODY-FAT ESTIMATED FROM ANTHROPOMETRIC AND ELECTRICAL-IMPEDANCE MEASUREMENTS
    PASCO, JA
    RUTISHAUSER, IHE
    [J]. HUMAN NUTRITION-CLINICAL NUTRITION, 1985, 39C (05): : 365 - 369
  • [3] BODY-FAT MEASUREMENT - WEIGHING THE PROS AND CONS OF ELECTRICAL-IMPEDANCE
    NASH, HL
    [J]. PHYSICIAN AND SPORTSMEDICINE, 1985, 13 (11): : 124 - 128
  • [4] RELIABILITY OF NEAR-INFRARED INTERACTANCE BODY-FAT ASSESSMENT RELATIVE TO STANDARD ANTHROPOMETRIC TECHNIQUES
    SCHREINER, PJ
    PITKANIEMI, J
    PEKKANEN, J
    SALOMAA, VV
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 1995, 48 (11) : 1361 - 1367
  • [5] VALIDITY OF PERCENT BODY-FAT ESTIMATIONS IN MALES
    STOUT, JR
    ECKERSON, JM
    HOUSH, TJ
    JOHNSON, GO
    BETTS, NM
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1994, 26 (05): : 632 - 636
  • [6] NEONATAL BODY-FAT MEASUREMENT NEAR-INFARED LIGHT INTERACTANCE
    ZUERLEIN, TJ
    HAYEN, LK
    SHAFFER, SG
    [J]. PEDIATRIC RESEARCH, 1989, 25 (04) : A299 - A299
  • [7] ELECTRICAL-IMPEDANCE IMAGING OF THE BODY WITH NONLINEAR RECONSTRUCTION
    KIM, YM
    TOMPKINS, WJ
    WEBSTER, JG
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 419 : 289 - 296
  • [8] THE VALIDITY OF VISUAL ESTIMATIONS OF PERCENT BODY-FAT IN LEAN MALES
    ECKERSON, JM
    HOUSH, TJ
    JOHNSON, GO
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1992, 24 (05): : 615 - 618
  • [9] NEAR-INFRARED INTERACTANCE IN ASSESSING SUPERFICIAL BODY-FAT IN EXCLUSIVELY BREAST-FED, FULL-TERM NEONATES
    KASA, N
    HEINONEN, KM
    [J]. ACTA PAEDIATRICA, 1993, 82 (01) : 1 - 5
  • [10] MEASUREMENT OF UPPER ARM MUSCLE AND FAT AREA BY ELECTRICAL-IMPEDANCE
    KARATZAS, T
    BROWN, BH
    CLARK, RG
    [J]. BRITISH JOURNAL OF SURGERY, 1986, 73 (12) : 1028 - 1028