Comparison of the Absorbed Dose of Target Organs between Conventional and Digital Panoramic Radiography

被引:0
|
作者
Reyhani, Zohre [1 ]
Avar, Nadia Nil [2 ]
Moghadam, Mohamad Ali [3 ]
机构
[1] Zanjan Univ Med Sci, Dept Oral & Maxillofacial Radiol, Fac Dent, Zanjan, Iran
[2] Tabriz Univ Med Sci, Dept Oral & Maxillofacial Radiol, Fac Dent, Tabriz, Iran
[3] Zanjan Univ Med Sci, Dept Restorat Dent, Fac Dent, Zanjan, Iran
关键词
Dosimetry; Conventional Panoramic; Digital Panoramic; Thyroid Gland;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The purpose of this study was to measure and compare target organ's exposure by direct digital and conventional panoramic radiography. Dose measurements were carried out on a RANDO phantom, which TLDs were placed into 5 target area: thyroid gland, left and right submandibular and parotid salivary glands. Panoramic radiographs were taken with two conventional (CRANEX Tome, Soredex, Tusula Finland) and direct digital devices (CRANEX D, Soredex, Tusula Finland). In total, the phantom was irradiated 30 times in the two systems. The TLDs were then coded and analyzed. T-test of statistical analysis was used to find the correlation. We found statistically significant reduction in absorbed dose of target organs in digital panoramic radiography(P<0.01). The highest absorbed dose was for submandibular gland and the lowest was for thyroid gland. We concluded that can reduce absorbed dose in vital organs.
引用
收藏
页码:28 / 31
页数:4
相关论文
共 50 条
  • [1] Quality comparison of direct digital panoramic radiography and computed radiography panoramic
    Goodarzipour, Dariush
    Motaghi, Reza
    Purtaji, Bahareh
    [J]. JOURNAL OF ORAL HEALTH AND ORAL EPIDEMIOLOGY, 2013, 2 (02): : 70 - 74
  • [2] Absorbed dose determination for intraoral digital radiography
    Kavadella, A
    Nicopoulou-Karayianni, K
    Donta-Bakoyianni, C
    Kamenopoulou, V
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B272 - B272
  • [3] Radiation dose reduction in direct digital panoramic radiography
    Gavala, Sophia
    Donta, Catherine
    Tsiklakis, Kostas
    Boziari, Argyro
    Kamenopoulou, Vasiliki
    Stamatakis, Harry C.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) : 42 - 48
  • [4] The subjective image quality of direct digital and conventional panoramic radiography
    Gijbels F.
    De Meyer A.-M.
    Bou Serhal C.
    Van den Bossche C.
    Declerck J.
    Persoons M.
    Jacobs R.
    [J]. Clinical Oral Investigations, 2000, 4 (3) : 162 - 167
  • [5] INTEGRAL ABSORBED DOSE IN CONVENTIONAL AND PANORAMIC COMPLETE-MOUTH EXAMINATIONS
    VANAKEN, J
    VANDERLI.LW
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1966, 22 (05): : 603 - &
  • [6] Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems
    Sabarudin, Akmal
    Tiau, Yu Jin
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2013, 3 (01) : 43 - 48
  • [7] A COMPARISON OF DIGITAL RADIOGRAPHY AND CONVENTIONAL FILM SCREEN RADIOGRAPHY
    KALENDER, WA
    HUBENER, KH
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 140 (01): : 87 - 92
  • [8] Comparison of panoramic radiography and panoramic digital subtraction radiography in the detection of simulated osteophytic lesions of the mandibular condyle
    Masood, F
    Katz, JO
    Hardman, PK
    Glaros, AG
    Spencer, P
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 93 (05): : 626 - 631
  • [9] A comparison of diagnostic accuracy of a newly developed photofluorographic panoramic system with conventional panoramic radiography
    Nagata, Y
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (03) : 137 - 140
  • [10] A CLINICAL COMPARISON BETWEEN CONVENTIONAL AND DIGITAL MAMMOGRAPHY UTILIZING COMPUTED RADIOGRAPHY
    BRETTLE, DS
    WARD, SC
    PARKIN, GJS
    COWEN, AR
    SUMSION, HJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (797): : 464 - 468