EFFECT OF LOW FRESH GAS-FLOW RATES ON INSPIRED GAS-COMPOSITION IN A CIRCLE ABSORBER SYSTEM

被引:8
|
作者
GREGORINI, P
机构
[1] Department of Anesthesia, C.A. Pizzardi Maggiore Hospital, Bologna
关键词
ANESTHETIC TECHNIQUES; LOW-FLOW ANESTHESIA; ANESTHETIC GAS; NITROUS OXIDE; OXYGEN; INSPIRED FRACTION OF;
D O I
10.1016/0952-8180(92)90214-L
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To determine the effects of fresh gas flow on inspired gas composition during low-flow anesthesia. Design: Randomized trial with 2-hour observation periods in patients assigned to one of three groups. Setting: Inpatient surgery clinic at a medical center. Patients: Thirty-six patients undergoing abdominal surgery with low-flow anesthesia. Interventions: Fresh gas flow was given at a starting rate of 5 L/min for 6 minutes. Thereafter, the fresh gas flow setting was nitrous oxide (N2O) 1 L/min and oxygen (O2) 0.6 L/min (Group 1), N2O 0.5 L/min and 0, 0.5 L/min (Group 2), and with a moderate surplus of N2O and 02 with respect to the patient's 02 Consumption (Group 3). Measurements and Main Results: The inspired 02 concentration (FIO2) was measured using a paramagnetic technique, and N2O levels were measured with infrared sensors; the inspired nitrogen concentration (FIN2) was calculated by the following formula: FIN2 = 1 - FIO2 - FIN2O, where FIN2O is the inspired N2O concentration. After 1 hour of anesthesia, FIO2 was significantly lower in Group 1 than in Groups 2 and 3 (p < 0.01), and FIN2 was significantly higher in Groups 2 and 3 than in Group 1 (p < 0.01). After 2 hours of anesthesia, FIN2 returned to normal in Group 2 but continued to increase in Group 3. FIN2O was close to 0. 7 % only in Group 1. Conclusions: The same initial period of denitrogenation is not adequate to denitrogenate the circle system in all cases. The lower the fresh gas flow, the longer the initial period of denitrogenation should be. Various levels of fresh gas flow for low-flow anesthesia have been suggested, but none guarantees adequate control of inspired gas composition unless flowmeters are continuously adjusted.
引用
下载
收藏
页码:439 / 443
页数:5
相关论文
共 50 条
  • [1] USE OF LOW FRESH GAS-FLOW OF ENTONOX WITH THE CIRCLE SYSTEM
    ALLISON, RH
    WISHART, HY
    SPENCE, AA
    BRITISH JOURNAL OF ANAESTHESIA, 1980, 52 (09) : P955 - P956
  • [2] SEVOFLURANE DEGRADATION IN A CIRCLE SYSTEM AT 2 DIFFERENT FRESH GAS-FLOW RATES
    MUNDAY, IT
    FODEN, ND
    WARD, PM
    VANPELT, FNAM
    JONES, RM
    ANESTHESIOLOGY, 1994, 81 (3A) : A433 - A433
  • [3] ISOFLURANE IN A CIRCLE SYSTEM WITH LOW GAS-FLOW
    REVELL, SP
    TAYLER, DH
    BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (10) : 1219 - 1222
  • [4] RELATION OF PACO2 TO FRESH GAS-FLOW IN A CIRCLE SYSTEM
    PATEL, K
    BENNETT, EJ
    GRUNDY, EM
    IGNACIO, A
    ANESTHESIA AND ANALGESIA, 1976, 55 (05): : 706 - 708
  • [5] FRESH GAS-FLOW
    KLIDE, AM
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 1992, 22 (02) : 381 - 382
  • [6] DIGITAL REGULATION OF GAS-FLOW RATES AND COMPOSITION OF GAS-MIXTURES
    LUNDSGAARD, J
    DEGN, H
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (05) : 384 - 387
  • [7] FRESH GAS-FLOW REQUIREMENTS WITH THE ADE ANESTHETIC SYSTEM
    FISHER, GC
    BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (02) : 241 - 242
  • [8] A GAS METER FOR LOW RATES OF GAS-FLOW - APPLICATION TO THE METHANE FERMENTATION
    MOLETTA, R
    ALBAGNAC, G
    BIOTECHNOLOGY LETTERS, 1982, 4 (05) : 319 - 322
  • [9] Pre-oxygenation in pregnancy: the effect of fresh gas flow rates within a circle breathing system
    Russell, E. C.
    Wrench, I.
    Feast, M.
    Mohammed, F.
    ANAESTHESIA, 2008, 63 (08) : 833 - 836
  • [10] ABSOLUTE DISPLACEMENT METER FOR LOW GAS-FLOW RATES
    TRUBIN, AM
    KHANBERG, VA
    MEASUREMENT TECHNIQUES USSR, 1987, 30 (10): : 984 - 986