INVESTIGATION OF CORROSION PREVENTION METHOD FOR DETERMINATION OF STEEL STRUCTURE CONDITION

被引:0
|
作者
DUKIC, LD
STERN, I
机构
[1] UNIV ZAGREB,FAC CHEM ENGN & TECHNOL,PIEROTTIJEVA 6,POB 177,ZAGREB 41001,CROATIA
[2] UNIV ZAGREB,FAC CIVIL ENGN,ZAGREB 41001,CROATIA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion influences the service life of building materials and accordingly the service life of whole structures. In order to avoid corrosion activity it is necessary to separate the structures from the aggressive environment. It is very important to consider the materials, structure functions, environment and adequate protection against corrosion. The investigation has been made to develop a comprehensive expert system corrosion prevention method (ES-CPM), to establish the condition of corrosion protection on structures during their service life. New types of assessment have been proposed to create a uniform assessment of corrosion protection on structures, and an optimum procedure has been developed for its maintenance. An expert system has also been developed to select a corrosion protection system during the erection of steel structures and throughout their service life.
引用
收藏
页码:167 / 183
页数:17
相关论文
共 50 条
  • [1] Corrosion and prevention method in port steel structures
    Yamaji, Toru
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2008, 94 (06): : A356 - A359
  • [2] CORROSION PREVENTION FOR STEEL
    VANOETER.KA
    [J]. FETTE SEIFEN ANSTRICHMITTEL VERBUNDEN MIT DER ZEITSCHRIFT DIE ERNAHRUNGSINDUSTRIE, 1972, 74 (06): : 339 - &
  • [3] Determination of corrosion of the steel reinforcement and application to a bridge structure
    Kotes, P.
    Brodnan, M.
    Vanerek, J.
    [J]. MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 485 - 485
  • [4] A METHOD FOR INVESTIGATION OF EFFECT OF STRESS ON GAS CORROSION OF STEEL
    ARCHAKOV, YI
    GOLUBOVS.BS
    ILICHEV, VI
    [J]. INDUSTRIAL LABORATORY, 1965, 31 (07): : 1087 - &
  • [5] THE DETERMINATION OF THE CORROSION RATE OF STEEL IN CONCRETE BY A NONSTATIONARY METHOD
    FELIU, S
    GONZALEZ, JA
    ANDRADE, C
    FELIU, V
    [J]. CORROSION SCIENCE, 1986, 26 (11) : 961 - &
  • [6] Steel structure corrosion prevention in power industry - further considerations
    Gdesz, Marek
    Szymanski, Krzysztof
    Augustynski, Lukasz
    [J]. OCHRONA PRZED KOROZJA, 2018, 61 (07): : 192 - 193
  • [7] Method of Corrosion Prevention in Steel Pressure Pipelines in Sewerage Systems
    Moskvicheva, E. V.
    Sidyakin, P. A.
    Shitov, D. V.
    [J]. 2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING (ICIE-2016), 2016, 150 : 2381 - 2386
  • [8] Investigation of corrosion rate on the modified 410 martensitic stainless steel in tempered condition
    Prifiharni, S.
    Sugandi, M. T.
    Pasaribu, R. R.
    Sunardi
    Mabruri, E.
    [J]. INTERNATIONAL SEMINAR ON METALLURGY AND MATERIALS, 2019, 541
  • [9] DETERMINATION OF STEEL CORROSION RATE
    Hajkova, K.
    Jendele, L.
    Smilauer, V.
    [J]. ENGINEERING MECHANICS 2016, 2016, : 186 - 189
  • [10] Cathode corrosion prevention of steel in concrete
    Eichler, Thorsten
    Isecke, Bernd
    Klein, Hans-H.
    Schade, Andreas
    Pruckner, Franz
    Michel, Stefan
    [J]. BETON- UND STAHLBETONBAU, 2007, 102 (05) : 310 - 320