ROLE OF DUPLEX SCANNING FOR THE DETECTION OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE

被引:138
|
作者
HOFFMANN, U
EDWARDS, JM
CARTER, S
GOLDMAN, ML
HARLEY, JD
ZACCARDI, MJ
STRANDNESS, DE
机构
[1] UNIV WASHINGTON, SCH MED, DEPT SURG, VASC SURG SECT, RF-25, SEATTLE, WA 98195 USA
[2] UNIV WASHINGTON, SCH MED, DEPT RADIOL, SEATTLE, WA 98195 USA
关键词
D O I
10.1038/ki.1991.156
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To assess the accuracy of renal artery duplex scanning for the purpose of diagnosing atherosclerotic renal artery stenosis, we compared the findings of renal arteriograms to the results of duplex scanning in 41 patients. Using an increase of renal artery peak systolic flow velocity of greater than 180 cm/sec, duplex scanning was able to discriminate normal from diseased renal arteries with a sensitivity of 95% and a specificity of 90%. Using the principle that blood flow velocity across a stenosis is roughly proportional to the degree of stenosis, it appeared that a ratio of the peak velocity in the renal artery to the aorta (RAR) of greater 3.5 predicted a greater than 60% diameter reduction of that renal artery, which is felt to be a significant stenosis. Forty-eight vessels were classified as having a greater than 60% diameter reduction by arteriography. Using the RAR of greater than 3.5, duplex scanning agreed in 44 renal arteries (sensitivity 92%). In the 26 renal arteries where arteriography showed a less than 60% diameter reduction, duplex scanning agreed in 16 vessels and correctly detected a focal narrowing in nine of the remaining ten vessels. Ten of 11 occluded renal arteries were correctly identified by duplex scanning. Duplex scanning determined the location of the renal artery lesion with an accuracy of 95% (kappa 0.74). Since duplex scanning can accurately demonstrate and locate focal renal artery stenosis, we believe it may become an accurate screening test for renovascular hypertension. A renal artery velocity increase to greater than 180 cm/s is an accurate predictor of renal artery disease, and a RAR of greater than 3.5 is an accurate predictor of a significant renal artery stenosis.
引用
收藏
页码:1232 / 1239
页数:8
相关论文
共 50 条
  • [2] DUPLEX IMAGING FOR THE DETECTION OF RENAL-ARTERY STENOSIS
    STRANDNESS, DE
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (04) : 674 - 678
  • [3] NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ULTRASONIC DUPLEX SCANNING
    KOHLER, TR
    ZIERLER, RE
    MARTIN, RL
    NICHOLLS, SC
    BERGELIN, RO
    KAZMERS, A
    BEACH, KW
    STRANDNESS, DE
    [J]. JOURNAL OF VASCULAR SURGERY, 1986, 4 (05) : 450 - 456
  • [4] Individual kidney function in atherosclerotic renal-artery disease
    Scoble, JE
    Mikhail, A
    Reidy, J
    Cook, GJR
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (04) : 1048 - 1049
  • [5] THE VALUE OF RENAL DUPLEX SCANNING (RDS) IN DIAGNOSIS OF RENAL-ARTERY STENOSIS (RAS)
    NANRA, RS
    BRAY, AE
    HARRISON, K
    LEWIS, W
    [J]. KIDNEY INTERNATIONAL, 1994, 45 (04) : 1266 - 1266
  • [6] ATHEROSCLEROTIC RENAL-ARTERY STENOSIS
    CAIRNS, HS
    [J]. LANCET, 1992, 340 (8814): : 298 - 299
  • [7] RENAL-ARTERY ANGIOPLASTY IN SEVERE ATHEROSCLEROTIC RENOVASCULAR DISEASE
    BIRD, RL
    WARWICK, R
    HILSON, A
    SWEENEY, P
    PLATTS, A
    HAMILTON, G
    [J]. BRITISH JOURNAL OF SURGERY, 1995, 82 (04) : 561 - 561
  • [8] MANAGEMENT OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE IN YOUNGER PATIENTS
    FERGANY, A
    NOVICK, AC
    GOLDFARB, DA
    [J]. JOURNAL OF UROLOGY, 1994, 151 (01): : 10 - 12
  • [9] ATHEROSCLEROTIC RENAL-ARTERY STENOSIS
    STANSBY, G
    HAMILTON, G
    SCOBLE, J
    [J]. BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (06): : 388 - &
  • [10] DUPLEX ULTRASOUND SCANNING IN THE DIAGNOSIS OF RENAL-ARTERY STENOSIS - A PROSPECTIVE EVALUATION
    TAYLOR, DC
    KETTLER, MD
    MONETA, GL
    KOHLER, TR
    KAZMERS, A
    BEACH, KW
    STRANDNESS, DE
    [J]. JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) : 363 - 369