DEVELOPMENT AND LABORATORY TESTING OF A 138-KV PPP-INSULATED JOINT FOR COMMERCIAL APPLICATION

被引:0
|
作者
WALLDORF, SP [1 ]
CHU, H [1 ]
ELBADALY, H [1 ]
机构
[1] CONSOLIDATED EDISON CO NEW YORK INC,DEPT ELECT ENGN,NEW YORK,NY
关键词
EHV; HPOF Splice; Joint; PPP-Insulated; Taped Splice; Underground Transmission;
D O I
10.1109/61.53086
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design, development and laboratory testing of a PPP-insulated joint for commercial application on 138-kV PPP insulated cable is presented. The design approach taken is conservative and addresses the typical variations in field conditions and in skill and workmanship of the splicing. Joint construction details, including choice of connector, taping structure, and joint mechanical reinforcement, are discussed. The test criteria are described and results are presented. © 1990 IEEE
引用
收藏
页码:799 / 805
页数:7
相关论文
共 24 条
  • [1] DEVELOPMENT OF A 138-KV SUPERCONDUCTING CABLE TERMINATION
    MAUSER, SF
    BURGHARDT, RR
    FENGER, ML
    DAKIN, TW
    MEYERHOFF, RW
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (03): : 909 - 914
  • [2] OPTIMIZED PPP-INSULATED PIPE TYPE CABLE SYSTEM FOR THE COMMERCIAL VOLTAGE RANGE
    ALLAM, EM
    MCKEAN, AL
    TETI, FA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (02) : 440 - 447
  • [3] Application studies of line arresters in partially shielded 138-kV transmission lines
    Zanetta, LC
    Pereira, CED
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) : 95 - 100
  • [4] DEVELOPMENT AND INSTALLATION OF 138-KV CABLE FOR TESTS AT EEI WALTZ MILL STATION - CABLE 24
    BLAIS, LD
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (04): : 1448 - &
  • [5] DESIGN AND TESTING OF A 138 KV PROTOTYPE TERMINATION FOR A VACUUM INSULATED LN2 CRYOCABLE
    GRANEUA, P
    THOMPSON, LB
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (04): : 1063 - 1064
  • [6] DEVELOPMENT OF TECHNOLOGY FOR MANUFACTURE OF CROSSLINKED POLYETHYLENE INSULATED CABLES RATED 138 THROUGH 345 KV
    BAHDER, G
    KATZ, C
    EAGER, GS
    SILVER, DA
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (06): : 1741 - 1753
  • [7] DEVELOPMENT OF 500 KV GAS INSULATED SWITCHGEAR AND ITS APPLICATION
    MORII, K
    YAMASHITA, Y
    HARUMOTO, Y
    USHIO, T
    MORIOKA, S
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1945 - 1957
  • [8] Overview of development, design, testing and application of compact gas-insulated DC systems up to ±550 kV
    Maria Kosse
    Karsten Juhre
    Mark Kuschel
    Dejun Li
    [J]. Global Energy Interconnection, 2019, 2 (06) : 568 - 578
  • [9] DEVELOPMENT OF 138 KV TRANSITION JOINT BETWEEN HPPT CABLE AND EXTRUDED CABLE
    CHU, H
    GHAFURIAN, R
    MAGUIRE, K
    PARMIGIANI, B
    WALKER, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) : 1718 - 1723
  • [10] DEVELOPMENT AND APPLICATION OF 500 kV GAS INSULATED TRANSMISSION LINES.
    Araki, Tomoo
    [J]. 1600, (25):