A COMPARISON BETWEEN DONOR-RECIPIENT CORNEAL SIZE AND ITS EFFECT ON THE ULTIMATE REFRACTIVE ERROR INDUCED IN KERATOCONUS

被引:33
|
作者
JAVADI, MA
MOHAMMADI, MJ
MIRDEHGHAN, SA
SAJJADI, SH
机构
[1] Department of Ophthalmology, Labbafinejad Medical Center, Tehran 16666
关键词
KERATOCONUS; DONOR-RECIPIENT SIZE; REFRACTIVE ERROR; ASTIGMATISM; KERATOMETRY;
D O I
10.1097/00003226-199309000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A prospective randomized clinical study was performed to see the effect of donor-recipient corneal size on the ultimate refractive error induced in keratoconus at our facility. The patients were randomly divided into two groups, A and B. In Group A, the difference in size between the donor and the recipient cornea was 0.25 mm (18 patients). In Group B, the difference in size between the donor and the recipient cornea was 0.50 mm (20 patients). Both groups underwent the surgical procedure with the same surgeon (M.A.J.) and the same technique. Two months after suture removal, keratometry readings and refractive errors induced were compared. The mean keratometry reading in Group A was 43.3 diopters; in Group B, the reading was 44.8 diopters. There was a mean difference of 1.5 diopters between the two groups (p = 0.01). The mean refractive error in terms of spherical equivalent in Group A was - 1.55 diopters and in Group B was - 3.33 diopters. There was a difference of - 1.8 diopters between the two groups (p < 0.05).
引用
收藏
页码:401 / 405
页数:5
相关论文
共 20 条
  • [1] A comparison of the effect of donor-recipient trephine size disparity on refractive error in keratoconus
    Shoja, Mohammad R.
    Besharati, Mohammad R.
    SAUDI MEDICAL JOURNAL, 2007, 28 (09) : 1389 - 1392
  • [2] EFFECT OF RECIPIENT-DONOR TREPHINE SIZE DISPARITY ON REFRACTIVE ERROR IN KERATOCONUS
    WILSON, SE
    BOURNE, WM
    OPHTHALMOLOGY, 1989, 96 (03) : 299 - 304
  • [3] EFFECT OF RECIPIENT-DONOR TREPHINE SIZE DISPARITY ON REFRACTIVE ERROR IN KERATOCONUS - DISCUSSION
    MEYER, RF
    MUSCH, DC
    OPHTHALMOLOGY, 1989, 96 (03) : 304 - 305
  • [4] Penetrating Keratoplasty in Keratoconus: Effect of Donor Trephine sizing, Based on Posterior Axial Length and Corneal Topography, in Postoperative Refractive Error
    Yuksel, Bora
    Cakmak, Aylin
    Bati, Hilal
    Topaloglu, Engin
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2009, 39 (04): : 267 - 271
  • [5] Comparison and Correlation of the Donor-Recipient Interface Changes and Visual Outcomes Between nDSEK and DSEK
    Huang, Minghai
    Hoang, Thuthuy
    Yin, Guina
    Liang, Yanqing
    Wu, Zhifeng
    Teng, Jian
    Zhang, Zhuoyuan
    Wei, Dongmei
    JOURNAL OF OPHTHALMOLOGY, 2025, 2025 (01)
  • [6] Living donor liver transplantation and its effect on the donor-recipient relationship - a qualitative interview study with donors
    Papaehristou, C.
    Walter, M.
    Schmid, G.
    Frommer, J.
    Klapp, B. F.
    CLINICAL TRANSPLANTATION, 2009, 23 (03) : 382 - 391
  • [7] Quantification of the surgically induced refractive effect of intrastromal corneal ring segments in keratoconus with standardized incision site and segment size
    Tu, Kyaw L.
    Sebastian, Rani T.
    Owen, Manon
    Batterbury, Mark
    Kaye, Stephen B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1865 - 1870
  • [8] The Effect of Donor-Recipient Heart Mass and Size Matching in Primary Graft Dysfunction Development after Heart Transplantation
    Gilbert, M. D.
    Morejon, P. A.
    Renedo, M. F.
    Giordanino, E. F.
    Favaloro, L. E.
    Ratto, R. D.
    Absi, D. O.
    Favaloro, R. R.
    Bertolotti, A. M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S25 - S25
  • [9] ASSESSMENT OF DONOR-RECIPIENT SIZE MISMATCH BASED ON BODY SURFACE AREA INDEX AND ITS IMPLICATIONS ON OUTCOMES OF DECEASED-DONOR LIVER TRANSPLANTS
    Kostakis, Ioannis D.
    Raptis, Dimitri A.
    Davidson, Brian R.
    Iype, Satheesh
    Nasralla, David
    Imber, Charles
    Sharma, Dinesh
    Pissanou, Theodora
    Pollok, Joerg-Matthias
    TRANSPLANT INTERNATIONAL, 2021, 34 : 16 - 16
  • [10] EFFECT OF DONOR-RECIPIENT SIZE MISMATCH ON LEFT-VENTRICULAR REMODELING AFTER PEDIATRIC ORTHOTOPIC HEART-TRANSPLANTATION
    KERTESZ, NJ
    GAJARSKI, RJ
    TOWBIN, JA
    GEVA, T
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (16): : 1167 - 1172