摘要
Background & aims: The thickness of the adductor pollicis muscle (TAPM) is the only muscle that can be directly measured with a caliper. Recent studies demonstrate that the TAPM could be used as part of nutritional screening, but this has not been systematically reviewed. We aimed to review the validity and reliability of TAPM in identifying malnutrition risk. Methods: PubMed, CINAHL and Scopus were systematically searched. Eligible studies were cross-sectional, case-control or cohort studies which recruited adult patients in the hospital, measured the TAPM along with a valid nutritional assessment tool and evaluated the validity of TAPM with univariate, multivariate, discriminative and/or agreement statistics. The Quality Assessment of Diagnostic Accuracy Studies-II was used to evaluate the risk-of-bias. Results: Nine out of 39 studies identified were eligible, and all had some risk-of-bias. Subjective Global Assessment (SGA) was used as the criterion standard in all nine studies. The TAPM amongst malnourished patients were significantly different from their counterparts but this may be over-estimated since all measurements of the SGA and TAPM were non-blinded. Concordance between the TAPM and SGA ranged from poor to good (kappa ranged from 0.04 to 0.25; specificity ranged from 97.8% to 100%), and this may be due to the varied cut-off values used amongst the studies. There were also disparities in the measurement instruments and methods. Reliability was not reported. Conclusion: More studies are needed to establish the reliability of TAPM measurement and cut-off values before the TAPM can be used as a component of nutritional screening. (c) 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Adductor Pollicis Muscle Thickness for nutritional assessment: a systematic review
    de Lima Pereira, Priscila Moreira
    Neves, Felipe Silva
    Bastos, Marcus Gomes
    Carlos Candido, Ana Paula
    REVISTA BRASILEIRA DE ENFERMAGEM, 2018, 71 (06) : 3093 - 3102
  • [2] Use of adductor pollicis muscle thickness in hospitalized or ambulatory patients: a systematic review
    Ferreira da Silva Soares, Brunna Gabrielly
    Vicentini, Andrea Pereira
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2018, 26
  • [3] Adductor pollicis muscle thickness in the nutritional assessment of hospitalized patients
    Barbosa, Marclei Costa
    Novaes, Taiane Goncalves
    Santos Silva, Thalane Souza
    RBONE-REVISTA BRASILEIRA DE OBESIDADE NUTRICAO E EMAGRECIMENTO, 2021, 15 (94): : 419 - 426
  • [4] Thickness of the adductor pollicis muscle in nutritional assessment of surgical patients
    Valente, Katarina Papera
    Fraga Silva, Naira Marceli
    Faioli, Amanda Barcelos
    Barreto, Marina Abelha
    Guedes de Moraes, Rafael Araujo
    Guandalini, Valdete Regina
    EINSTEIN-SAO PAULO, 2016, 14 (01): : 18 - 24
  • [5] Adductor pollicis muscle and nutritional status in heart failure patients: Is there an association?
    Duarte, Rodrigo R.
    Cristina Gonzalez, M.
    Oliveira, Jacqueline F.
    Oliveira, Patricia C.
    Castro, Iran
    NUTRITION, 2019, 67-68
  • [6] Adductor pollicis muscle: A study about its use as a nutritional parameter in surgical patients
    Gonzalez, Maria Cristina
    Pureza Duarte, Rodrigo Roig
    Orlandi, Silvana Paiva
    Bielemann, Renata Moraes
    Barbosa-Silva, Thiago Gonzalez
    CLINICAL NUTRITION, 2015, 34 (05) : 1025 - 1029
  • [7] Association of Adductor Pollicis Muscle Thickness and Handgrip Strength with nutritional status in cancer patients
    Valente, Katarina Papera
    Almeida, Betullya Lucas
    Lazzarini, Thailiny Ricati
    de Souza, Vanusa Felicio
    Chaves Ribeiro, Thamirys de Souza
    Guedes de Moraes, Rafael Araujo
    Silva Pereira, Taisa Sabrina
    Guandalini, Valdete Regina
    PLOS ONE, 2019, 14 (08):
  • [8] Adductor pollicis muscle and handgrip strength: potential methods of nutritional assessment in surgical patients
    Giglio, Bruna Melo
    Schincaglia, Raquel Machado
    Vaz de Souza Freitas, Ana Tereza
    Ferreira Stringhini, Maria Luiza
    MUNDO DA SAUDE, 2021, 45 (01): : 595 - 605
  • [9] Association of adductor pollicis muscle thickness and handgrip strength with nutritional status in hospitalized individuals
    da Costa, Talita Yoshimura
    Suganuma, Juliana Yukari
    de Faria, Sheilla
    Bernardes Spexoto, Maria Claudia
    NUTRICION HOSPITALARIA, 2021, 38 (03) : 519 - 524
  • [10] Association between adductor pollicis muscle thickness and nutritional parameters in hospitalized elderly patients
    El Kik, Raquel Milani
    Dorneles, Thamiris de Christo
    Augustin Schwanke, Carla Helena
    NUTRICION HOSPITALARIA, 2018, 35 (05) : 1059 - 1065