LONG-TERM REPRODUCIBILITY, OF AMBULATORY BLOOD-PRESSURE

被引:0
|
作者
MANSOOR, GA [1 ]
MCCABE, EJ [1 ]
WHITE, WB [1 ]
机构
[1] UNIV CONNECTICUT,SCH MED,DEPT MED,HYPERTENS & VASC DIS SECT,FARMINGTON,CT 06032
关键词
AMBULATORY BLOOD PRESSURE; REPRODUCIBILITY;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To compare the reproducibility of ambulatory and office blood pressure readings in established hypertensive subjects when studies are repeated at extended time intervals. Subjects: Twenty-five hypertensive patients (office diastolic blood pressure greater than or equal to 90 mmHg) who were off antihypertensive therapy for at least 4 weeks and had repeat office and ambulatory blood pressures at least 3 months apart under similar study conditions. Methods: On the same day, patients underwent office blood pressure readings measured by mercury column sphygmomanometry and then by ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring was done for 24 h, and awake and sleep periods were divided according to a diary kept by each patient. A second study was performed in an identical manner at a mean +/- SD interval of 23 +/- 24 months (range 3-80, median 15). The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). Results: There were no significant differences in office, 24-h, awake and sleep mean blood pressures between the two studies. Mean 24-h systolic and diastolic blood pressures were 16 and 14 mmHg lower, respectively, than office blood pressure values. Correlation coefficients were significantly higher for 24-h ambulatory blood pressure than office blood pressure, whereas the SDD between visits was significantly lower for 24-h ambulatory blood pressure than office blood pressure. Conclusions: These data demonstrate that long-term reproducibility of ambulatory blood pressure is superior to that for office measurement. One implication of this finding is that, in long-term clinical pharmacology trials utilizing ambulatory blood pressure, fewer subjects would be required than for studies that used office blood pressure end-points.
引用
收藏
页码:703 / 708
页数:6
相关论文
共 50 条
  • [1] LONG-TERM AMBULATORY BLOOD-PRESSURE MONITORING
    SEMLER, HJ
    JOURNAL OF HYPERTENSION, 1986, 4 : S556 - S556
  • [2] Medium and long-term reproducibility ambulatory blood pressure.
    Livi, R
    Teghini, L
    Scarpelli, PT
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 154A - 154A
  • [3] REPRODUCIBILITY OF AMBULATORY BLOOD-PRESSURE
    MANN, S
    GOULD, BA
    CRAIG, MWM
    RAFTERY, EB
    CLINICAL SCIENCE, 1985, 68 : P42 - P42
  • [4] AMBULATORY LONG-TERM BLOOD-PRESSURE MONITORING - WHAT IS NORMAL
    BAUMGART, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1991, 80 : 29 - 32
  • [5] Long-term reproducibility of ambulatory blood pressure in unselected elderly subjects
    Wendelin-Saarenhovi, M
    Isoaho, R
    Hartiala, J
    Helenius, H
    Kivelä, SL
    Hietanen, E
    CLINICAL PHYSIOLOGY, 2001, 21 (03): : 316 - 322
  • [6] Long-term reproducibility of ambulatory blood pressure is superior to office blood pressure in the very elderly
    P Campbell
    N Ghuman
    D Wakefield
    L Wolfson
    W B White
    Journal of Human Hypertension, 2010, 24 : 749 - 754
  • [7] Long-term reproducibility of ambulatory blood pressure is superior to office blood pressure in the very elderly
    Campbell, P.
    Ghuman, N.
    Wakefield, D.
    Wolfson, L.
    White, W. B.
    JOURNAL OF HUMAN HYPERTENSION, 2010, 24 (11) : 749 - 754
  • [8] Long term reproducibility of ambulatory blood pressure monitoring
    Gosse, P
    Bougaleb, M
    Clementy, J
    THERAPIE, 1996, 51 (01): : 5 - 9
  • [9] LONG-TERM REPRODUCIBILITY AND EVALUATION OF SEASONAL INFLUENCE ON BLOOD-PRESSURE MONITORING
    GIACONI, S
    PALOMBO, C
    GENOVESIEBERT, A
    MARABOTTI, C
    VOLTERRANI, D
    GHIONE, S
    JOURNAL OF HYPERTENSION, 1988, 6 : S64 - S66
  • [10] REPRODUCIBILITY OF AMBULATORY BLOOD-PRESSURE LOAD
    ZACHARIAH, PK
    SHEPS, SG
    BAILEY, KR
    WILTGEN, CM
    MOORE, AG
    JOURNAL OF HUMAN HYPERTENSION, 1990, 4 (06) : 625 - 631