CODE OF PRACTICE FOR CLINICAL PROTON DOSIMETRY

被引:107
|
作者
VYNCKIER, S
BONNETT, DE
JONES, DTL
机构
[1] CATHOLIC UNIV LOUVAIN, CLIN ST LUC, B-1200 BRUSSELS, BELGIUM
[2] CLATTERBRIDGE HOSP, MRC, CYCLOTRON UNIV, BEBINGTON, ENGLAND
关键词
PROTON; CLINICAL BEAM; DOSIMETRY; CALIBRATION;
D O I
10.1016/0167-8140(91)90112-T
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The objective of this document is to make recommendations for the determination of absorbed dose to tissue for clinical proton beams and to achieve uniformity in proton dosimetry. A Code of Practice has been chosen, providing specific guidelines for the choice of the detector and the method of determination of absorbed dose for proton beams only. This Code of Practice is confined specifically to the determination of absorbed dose and is not concerned with the biological effects of proton beams. It is recommended that dosimeters be calibrated by comparison with a calorimeter. If this is not available, a Faraday cup, or alternatively, an ionization chamber, with a Co-60 calibration factor should be used. Physical parameters for determining the dose from tissue-equivalent ionization chamber measurements are given together with a worksheet. It is recommended that calibrations be carried out in water at the centre of the spread-out-Bragg-peak and that dose distributions be measured in a water phantom. It is estimated that the error in the calibrations will be less than +/- 5% (1 S.D.) in all cases. Adoption and implementation of this Code of Practice will facilitate the exchange of clinical information.
引用
收藏
页码:53 / 63
页数:11
相关论文
共 50 条
  • [1] SUPPLEMENT TO THE CODE OF PRACTICE FOR CLINICAL PROTON DOSIMETRY
    VYNCKIER, S
    BONNETT, DE
    JONES, DTL
    [J]. RADIOTHERAPY AND ONCOLOGY, 1994, 32 (02) : 174 - 179
  • [2] IPEM Code of Practice for proton and ion beam dosimetry: update on work in progress
    Green, S.
    Amos, R.
    Van den Heuvel, F.
    Kacperek, A.
    MacKay, R. I.
    Palmans, H.
    D'Souza, D.
    Thomas, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S783 - S784
  • [3] Considerations for a dosimetry code of practice for BNCT
    Green, Stuart
    Koivunoro, Hanna
    Kumada, Hiroaki
    [J]. HEALTH AND TECHNOLOGY, 2024, 14 (05) : 1017 - 1021
  • [4] A code of practice for the dosimetry of BNCT in Europe
    Stecher-Rasmussen, F
    Auterinen, I
    Beddoe, A
    Goncalves, I
    Jarvinen, H
    Kosunen, A
    Larsson, B
    Marek, M
    Mijnheer, B
    Raaijmakers, CPJ
    Savolainen, S
    Voorbraak, WP
    Watkins, P
    Zsolnay, E
    [J]. ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A237 - A240
  • [5] THE CODE OF PRACTICE FOR ELECTRON-BEAM DOSIMETRY
    PITCHFORD, G
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (707): : 1139 - 1140
  • [6] Dosimetry in diagnostic radiology: An international code of practice
    Ganesh, T.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2007, 32 (04) : 185 - 185
  • [7] Code of Practice for the Proton Therapy System
    Palta, J.
    Maughan, R.
    Slopsema, R.
    [J]. MEDICAL PHYSICS, 2009, 36 (06) : 2740 - +
  • [8] Reference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice
    Thomas, S. J.
    Aspradakis, M. M.
    Byrne, J. P.
    Chalmers, G.
    Duane, S.
    Rogers, J.
    Thomas, R. A. S.
    Tudor, G. S. J.
    Twyman, N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (06): : 1339 - 1352
  • [9] CODE OF PRACTICE FOR ELECTRON-BEAM DOSIMETRY IN RADIOTHERAPY
    不详
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (11): : 1169 - 1194
  • [10] Radiochromic film dosimetry for clinical proton beams
    Vatnitsky, SM
    [J]. APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 643 - 651