THE EFFECT OF BALLOON ANGIOPLASTY ON VASA VASORUM BLOOD-FLOW IN CANINE CORONARY-ARTERIES

被引:3
|
作者
EISENHAUER, AC
ALKER, K
KLONER, R
MATTHEWS, RV
机构
关键词
D O I
10.1016/0002-8703(90)90237-R
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the effects of balloon dilatation on vasa vasorum flow, we performed percutaneous transluminal coronary angioplasty on the circumflex arteries of 12 dogs. Left anterior descending and circumflex coronary vasa vasorum flows were measured with radioactive microspheres at baseline, during, and 10 minutes after a 3-minute, 8 atm balloon inflation. With inflation, vasa vasorum flow at the balloon dilatation site profoundly decreased (from 0.25 ± 0.08 to 0.03 ± 0.01 ml/min/gm). The flow returned to normal within 10 minutes after deflation. This effect was not mediated by hemodynamic deterioration during coronary occlusion and did not occur in the contralateral coronary artery. Endomyocardial flow in the distribution of the dilated artery decreased markedly during balloon inflation (from 1.14 ± 1.9 to 0.08 ± 0.04 ml/min/gm), which confirmed coronary occlusion. We conclude that a prolonged decrease in vasa vasorum flow is not produced by experimental balloon angioplasty, which makes it unlikely that a sustained vasa vasorum flow reduction plays a role in the maintenance of patency or the induction of restenosis. © 1990.
引用
收藏
页码:1285 / 1291
页数:7
相关论文
共 50 条
  • [1] BLOOD-FLOW THROUGH VASA VASORUM OF CORONARY-ARTERIES IN ATHEROSCLEROTIC MONKEYS
    HEISTAD, DD
    ARMSTRONG, ML
    [J]. ARTERIOSCLEROSIS, 1986, 6 (03): : 326 - 331
  • [2] EFFECT OF TREATMENT OF ATHEROSCLEROSIS ON VASA VASORUM IN CORONARY-ARTERIES
    WILLIAMS, JK
    ARMSTRONG, ML
    HEISTAD, DD
    [J]. CLINICAL RESEARCH, 1986, 34 (04): : A905 - A905
  • [3] BLOOD-FLOW THROUGH VASA VASORUM IN ARTERIES AND VEINS
    HEISTAD, DD
    ARMSTRONG, ML
    AMUNDSEN, S
    [J]. FEDERATION PROCEEDINGS, 1985, 44 (03) : 809 - 809
  • [4] BLOOD-FLOW IN CORONARY-ARTERIES
    ELLIOTT, LP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1980, 244 (06): : 604 - 604
  • [5] EFFECT OF MOLSIDOMINE ON CYCLIC BLOOD-FLOW REDUCTIONS IN STENOSED CANINE CORONARY-ARTERIES
    MARTORANA, PA
    GOBEL, H
    KEIL, M
    JUST, M
    NITZ, RE
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 108 - 108
  • [6] EFFECT OF SYMPATHETIC SIMULATION ON BLOOD-FLOW TO VASA VASORUM
    HEISTAD, DD
    MARCUS, ML
    ABBOUD, FM
    [J]. FEDERATION PROCEEDINGS, 1978, 37 (03) : 654 - 654
  • [7] REGRESSION OF VASA VASORUM IN CORONARY-ARTERIES DURING TREATMENT OF ATHEROSCLEROSIS
    WILLIAMS, JK
    ARMSTRONG, ML
    HEISTAD, DD
    [J]. CIRCULATION, 1986, 74 (04) : 335 - 335
  • [8] REGRESSION OF VASA VASORUM IN CORONARY-ARTERIES DURING TREATMENT OF ATHEROSCLEROSIS
    WILLIAMS, JK
    ARMSTRONG, ML
    HEISTAD, DD
    [J]. ARTERIOSCLEROSIS, 1986, 6 (05): : A555 - A555
  • [9] EFFECT OF VASODILATORS ON BLOOD-FLOW IN NORMAL AND STENOSED CORONARY-ARTERIES
    GALLAGHER, KP
    FOLTS, JD
    ROWE, GG
    [J]. FEDERATION PROCEEDINGS, 1976, 35 (03) : 345 - 345
  • [10] BIDIRECTIONAL BLOOD-FLOW IN HEALTHY CORONARY-ARTERIES
    SCHURTZ, C
    ALSAC, J
    BENS, JL
    BAUD, C
    FUNCK, F
    MASSELOT, M
    [J]. PRESSE MEDICALE, 1984, 13 (15): : 941 - 942