SIMPLE AND RELIABLE GAS-LIQUID-CHROMATOGRAPHIC ASSAY FOR UNDERIVATIZED THEOPHYLLINE IN PLASMA USING AN ORGANIC-NITROGEN SPECIFIC DETECTOR

被引:0
|
作者
CHAMBERS, RE
机构
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 171卷 / APR期
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plasma levels of the bronchodilator theophylline (1,3-dimethylxanthine) are now measured routinely in many laboratories and many methods have been described. There is a need for a reliable GLC procedure that possess the advantages of speed, simplicity and sensitivity for pediatric samples and which also eliminates the potential problems associated with derivative formation. A system that fulfills these criteria is described. This GLC procedure is both reliable and simple to perform. It is sufficiently sensitive to measure theophylline in pediatric samples, a large number of determinations can readily be carried out in 1 batch and a derivatization step is not required. The system is entirely suitable for the routine measurement of theophylline in plasma.
引用
收藏
页码:473 / 477
页数:5
相关论文
共 50 条
  • [1] SENSITIVE GAS-LIQUID-CHROMATOGRAPHIC ASSAY OF UNDERIVATIZED 5-FLUOROURACIL IN PLASMA
    DRIESSEN, O
    DEVOS, D
    TIMMERMANS, PJA
    JOURNAL OF CHROMATOGRAPHY, 1979, 162 (03): : 451 - 456
  • [2] GAS-LIQUID-CHROMATOGRAPHIC DETERMINATION OF NANOGRAM AMOUNTS OF CYCLOBENZAPRINE IN PLASMA USING A NITROGEN DETECTOR
    HUCKER, HB
    STAUFFER, SC
    JOURNAL OF CHROMATOGRAPHY, 1976, 124 (01): : 164 - 168
  • [3] GAS-LIQUID-CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN PLASMA
    DUSCI, LJ
    HACKETT, LP
    MCDONALD, IA
    JOURNAL OF CHROMATOGRAPHY, 1975, 104 (01): : 147 - 150
  • [4] ASSAY OF PHENYLBUTAZONE IN HUMAN PLASMA BY A SPECIFIC AND SENSITIVE GAS-LIQUID-CHROMATOGRAPHIC PROCEDURE
    MCGILVERAY, IJ
    MIDHA, KK
    BRIEN, R
    WILSON, L
    JOURNAL OF CHROMATOGRAPHY, 1974, 89 (01): : 17 - 22
  • [5] A RAPID GAS-LIQUID-CHROMATOGRAPHIC DETERMINATION OF SERUM LIDOCAINE USING A NITROGEN-PHOSPHORUS SPECIFIC DETECTOR
    KRUCZEK, ME
    JOURNAL OF PHARMACOLOGICAL METHODS, 1981, 5 (02): : 137 - 141
  • [6] RAPID, SENSITIVE GAS-LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF AMITRIPTYLINE AND NORTRIPTYLINE IN PLASMA USING A NITROGEN-SENSITIVE DETECTOR
    HUCKER, HB
    STAUFFER, SC
    JOURNAL OF CHROMATOGRAPHY, 1977, 138 (02): : 437 - 442
  • [7] GAS-CHROMATOGRAPHIC ASSAY FOR THIOPENTAL IN PLASMA, WITH USE OF A NITROGEN-SPECIFIC DETECTOR
    JUNG, D
    MAYERSOHN, M
    PERRIER, D
    CLINICAL CHEMISTRY, 1981, 27 (01) : 113 - 115
  • [8] IMPROVED GAS-LIQUID-CHROMATOGRAPHIC ASSAY FOR 5-FLUOROURACIL IN PLASMA
    VANDENBERG, HW
    MURPHY, RF
    HUNTER, R
    ELMORE, DT
    JOURNAL OF CHROMATOGRAPHY, 1978, 145 (02): : 311 - 314
  • [9] GAS-LIQUID-CHROMATOGRAPHIC DETERMINATION OF PENFLURIDOL IN PLASMA - NEW SPECIFIC TECHNIQUE
    COOPER, SF
    ALBERT, JM
    DUGAL, R
    INTERNATIONAL PHARMACOPSYCHIATRY, 1975, 10 (02): : 78 - 88
  • [10] SIMPLE AND RELIABLE GAS-CHROMATOGRAPHIC ASSAY FOR DETERMINATION OF CARBAMAZEPINE IN PLASMA
    CHAMBERS, RE
    COOKE, M
    JOURNAL OF CHROMATOGRAPHY, 1977, 144 (02): : 257 - 262