BALLOON-EXPANDABLE STENT IMPLANTATION AFTER IATROGENIC ARTERIAL DISSECTION OF THE LEFT SUBCLAVIAN ARTERY

被引:9
|
作者
GALLI, M
GOLDBERG, SL
ZERBONI, S
ALMAGOR, Y
机构
[1] UNIV CALIF LOS ANGELES,LOS ANGELES CTY HARBOR MED CTR,DIV CARDIOL,TORRANCE,CA 90509
[2] CTR CUORE COLUMBUS,MILAN,ITALY
[3] SHAARE ZEDEK MED CTR,JERUSALEM,ISRAEL
来源
关键词
PALMAZ STENT; SUBCLAVIAN ARTERY DISSECTION;
D O I
10.1002/ccd.1810350417
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A patient undergoing attempted angioplasty of a left internal mammary artery graft to left anterior descending coronary artery developed an iatrogenic dissection of the left subclavian artery, with symptoms of left arm claudication. A balloon expandable stent was inserted with an excellent angiographic result, The patient has remained free of symptoms or signs of decreased arm flow, with a patent subclavian artery demonstrated on angiography 8 months later, The excellent early-to-moderate term clinical and angiographic results support the efficacy of this technical approach. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:355 / 357
页数:3
相关论文
共 50 条
  • [1] Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    Liang, DK
    Yang, DZ
    Qi, M
    Wang, WQ
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (03) : 314 - 318
  • [2] Balloon-Expandable Covered Stent to Superficial Femoral Artery
    Tamura, Hiroto
    Yuba, Kenichiro
    Kurimoto, Shingo
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (08):
  • [3] THE MECHANICAL BEHAVIOR OF A BALLOON-EXPANDABLE STENT IN A STENOTIC ARTERY
    Imani, Misagh
    Goudarzi, A. M.
    Ganji, D. D.
    Gerdroodbary, M. Barzegar
    PROCEEDINGS OF THE ASME 12TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS - 2014, VOL 1, 2014,
  • [4] A BALLOON-EXPANDABLE INTRAVASCULAR STENT FOR OBLITERATING EXPERIMENTAL AORTIC DISSECTION
    TRENT, MS
    PARSONNET, V
    SHOENFELD, R
    BRENER, BJ
    EISENBUD, DE
    NOVICK, AS
    CAMPBELL, AY
    FERRARARYAN, M
    VILLANUEVA, A
    JOURNAL OF VASCULAR SURGERY, 1990, 11 (05) : 707 - 717
  • [5] BALLOON-EXPANDABLE INTRAVASCULAR STENT
    PALMAZ, JC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) : 1263 - 1269
  • [6] BALLOON-EXPANDABLE STENT OCCLUDER
    MOSS, JG
    LABORDE, JC
    CLEM, MF
    RIVERA, FJ
    ENCARNACION, CE
    LUTZ, JD
    RADIOLOGY, 1992, 185 : 134 - 134
  • [7] Balloon-expandable covered stent implantation for treatment of a traumatic pulmonary artery pseudoaneurysm in a pediatric patient
    Palmieri, Vincent J.
    Heal, Elisabeth
    Chowdhury, Shahryar M.
    Bandisode, Varsha M.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (02): : E73 - E76
  • [8] Disintegration of a Balloon-Expandable Stent in the Iliac Artery Upon Delivery
    Ozkan, Fuat
    Peynircioglu, Bora
    Canyigit, Murat
    Ergun, Onur
    Cil, Barbaros Erhan
    Cekirge, Saruhan
    EUROPEAN JOURNAL OF GENERAL MEDICINE, 2013, 10 : 90 - 93
  • [9] Unconventional Use of Balloon-Expandable Covered Stent in the Treatment of Iatrogenic Popliteal Pseudoaneurysm
    Alshatti, Hamad J.
    Ameer, Ahmad
    Rashid, Hisham
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [10] A case report of balloon-expandable vessel-covering stent for the treatment of spontaneous renal artery dissection
    Yuan, Guangqing
    Xiao, Yiming
    Zhang, Zhicheng
    Chen, Quan
    ASIAN JOURNAL OF SURGERY, 2024, 47 (03) : 1443 - 1444