Comparing Anti-bacterial Effect of CO2 Laser and 0.2% Chlorhexidine Solution on Staphylococcus aureus and Pseudomonas aeruginosa: In Vitro Study

被引:5
|
作者
Taghavi, Ali [1 ]
Asadollahi, Afsoon [1 ,2 ]
Eslami, Hosein [1 ]
Attaran, Rana [1 ]
Ranjkesh, Mohammad Reza [3 ,4 ]
Kafil, Hossein Samadi [5 ]
机构
[1] Tabriz Univ Med Sci, Fac Dent, Dept Oral & Maxillofacial Med, Tabriz, Iran
[2] Tabriz Univ Med Sci, Immunol Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Infect Dis & Trop Med Res Ctr, Tabriz, Iran
[4] Tabriz Univ Med Sci, Fac Med Sci, Dept Dermatol, Tabriz, Iran
[5] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
关键词
Antimicrobial; chlorhexidine; CO2; laser; Pseudomonas aeruginosa; Staphylococcus aureus;
D O I
10.1177/2229411220160106
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The bacterium causes different diseases in the oral cavity including angular cheilitis, bacterial sialadenitis in salivary glands, joint septic arthritis. In addition, the accumulation of bacteria on the surface of the implant develops the inflammation of mucous. The aim of this study was to compare the effects of CO2 laser with 2.0% chlorhexidine in a laboratory environment for eradicating Staphylococcus aureus and Pseudomonas aeruginosa. Materials and Methods: The effect of CO2 Laser was evaluated 5, 10, and 15 s after exposure to the standard suspension of bacterium at 24 and 48 h intervals and were cultured until the logarithmic phase and CO2 laser radiation with the wavelengths of 6 and 10 mu m and energy density of 12.5 J/cm(2) were radiated at a distance of 17 mm. Chlorhexidine 0.2% also was assessed at 5, 10, 15, and 60 s on the pathogens. Data were analyzed by descriptive statistics (mean +/- standard deviation) and repeated measures ANOVA using SPSS 17. The P < 0.05 was considered statistically significant. Results: CO2 laser radiation was effective at all < 15 s radiations on reducing both types of bacteria while the average numbers of S. aureus which were affected by 15 s of laser radiation and 60 s of chlorhexidine showed statistically significant difference (P = 0.014). The numbers of P. aeruginosa bacteria in the group which was exposed by laser for 15 s and the group which was treated by chlorhexidine were zero. Whereas, the average number of bacteria of laser treated group was lower than 0.2% chlorhexidine at both groups of bacteria. Laser radiation removed 100% of bacteria after 15 s in both groups of the bacteria. Conclusions: Findings of the present study indicate that laser irradiation for 15 s had equal results with chlorhexidine and more effective than 60 s treatment with chlorhexidine.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 31 条
  • [1] COMPARISON OF ANTI-BACTERIAL PROPERTIES OF LAURICIDIN AND BHA AGAINST ANTIBIOTIC-RESISTANT AND SENSITIVE STAPHYLOCOCCUS-AUREUS AND PSEUDOMONAS-AERUGINOSA
    VADEHRA, DV
    WAHI, V
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1983, 60 (04) : 715 - 715
  • [2] Evaluation of Anti-bacterial and Anti-quorum Sensing Potential of Essential Oils Extracted by Supercritical CO2 Method Against Pseudomonas aeruginosa
    Ganesh, P. Sankar
    Rai, V. Ravishankar
    JOURNAL OF ESSENTIAL OIL BEARING PLANTS, 2015, 18 (02) : 264 - 275
  • [3] Study of the inhibitory effect of Quercus Coccifera's aqueous extract on Staphylococcus aureus and Pseudomonas aeruginosa In vitro
    Judaki, Arezo
    Panahi, Jafar
    Havasian, Mohamad Reza
    Tajbakhsh, Parnian
    Roozegar, Mohamad Ali
    BIOINFORMATION, 2014, 10 (11) : 689 - 692
  • [4] Antibacterial activity of TiO2 nanoparticle coated endotracheal tubes: an in vitro study on Pseudomonas aeruginosa and Staphylococcus aureus
    Ball, L.
    Caratto, V
    Sanguineti, E.
    Firpo, I
    Ferretti, M.
    Pelosi, P.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 77 - 77
  • [5] The effect of Staphylococcus aureus on the antibiotic resistance and pathogenicity of Pseudomonas aeruginosa based on crc gene as a metabolism regulator: An in vitro wound model study
    Dehbashi, Sanaz
    Pourmand, Mohammad Reza
    Alikhani, Mohammad Yousef
    Asl, Sara Soleimani
    Arabestani, Mohammad Reza
    INFECTION GENETICS AND EVOLUTION, 2020, 85
  • [6] Synergistic antimicrobial effect of photodynamic therapy and chitosan on the titanium-adherent biofilms of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa: An in vitro study
    Camacho-Alonso, Fabio
    Salinas, Jesus
    Sanchez-Siles, Mariano
    Pato-Mourelo, Jesus
    Davis Cotrina-Veizaga, Brian
    Ortega, Nieves
    JOURNAL OF PERIODONTOLOGY, 2022, 93 (06) : E104 - E115
  • [7] Comparative study of the effects of the use of the CO2 laser and chlorohexidine on the healing of cutaneous wounds infected by the Staphylococcus aureus
    de Oliveira, MAM
    Pinheiro, ALB
    Moreira, ACA
    Ramalho, LMP
    Junior, AB
    Zanin, FA
    Lima, TLC
    LASERS IN DENTISTRY IX, 2003, 4950 : 122 - 130
  • [8] The effect of CO2 laser on the permeability of dentinal tubules:: A preliminary in vitro study
    Slutzky-Goldberg, Iris
    Nuni, Eyal
    Nasralla, Warda
    Stabholtz, Adam
    Moshonov, Joshua
    PHOTOMEDICINE AND LASER SURGERY, 2008, 26 (01) : 61 - 64
  • [9] Effect of CO2 laser on pulpal temperature and surface morphology:: an in vitro study
    Malmström, HS
    McCormack, SM
    Fried, D
    Featherstone, JDB
    JOURNAL OF DENTISTRY, 2001, 29 (08) : 521 - 529
  • [10] Bactericidal effect of the CO2 laser in the root canal an in-vitro study.
    Gutknecht, N
    Wilkert-Walter, C
    Lampert, F
    LASERS IN DENTISTRY IV, PROCEEDINGS OF, 1998, 3248 : 162 - 167