COMBINED PULSED FLAME PHOTOMETRIC IONIZATION DETECTOR

被引:15
|
作者
TZANANI, N [1 ]
AMIRAV, A [1 ]
机构
[1] TEL AVIV UNIV,SCH CHEM,IL-69978 TEL AVIV,ISRAEL
关键词
D O I
10.1021/ac00097a026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The pulsed flame photometric ionization detector (PFPID) is designed for the simultaneous selective detection of molecules containing carbon, sulfur, phosphorus, or nitrogen atoms using gas chromatography (GC). The PFPID is based on a pulsed name which propagates from the igniter through the ionization and photometric chambers consecutively, The flame is then self-terminated and reignited after a few hundred milliseconds in a pulsed periodic fashion. Since the pulsed name photometer works with a hydrogen-rich atmosphere, the GC eluting molecules are predominantly pyrolyzed and only slightly combusted in the initial pulsed name photometric chamber. These products are further combusted in the second pulsed flame ionization chamber, where the combustible gas mixture is separately optimized. The resulting electrons/ions are collected by an electrically isolated collector positively biased to 10 V, The addition of a pulsed flame ionization detector (PFID) to the pulsed name photometric detector (PFPD) requires addition of negligible hardware (an isolated charge collector). It also requires the addition of a current-to-voltage converter and a double-gated instead of a single-gated amplifier for simultaneous PFPD-PFID work The PFPID can be operated separately as either a pulsed FPD or a pulsed FID or simultaneously as both at the same H-2/air gas now rates. The simultaneous selective analysis of sulfur and organic compounds in gasoline, kerosene, and diesel fuel is demonstrated and discussed in terms of the various operational parameters. The performance of the PFPID is analyzed and compared to that of other sulfur and carbon simultaneous selective detection schemes.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [1] COMBINED FLAME-IONIZATION AND PHOTOMETRIC DETECTOR FOR SPECIFIC DETERMINATION OF ORGANOPHOSPHORUS COMPOUNDS
    SVOJANOVSKY, V
    NEBOLA, R
    CHEMICKE LISTY, 1973, 67 (03): : 295 - 301
  • [2] Pressure and gas composition effects on the operation of the pulsed flame photometric detector
    Frishman, G
    Amirav, A
    Barak, H
    ISRAEL JOURNAL OF CHEMISTRY, 2001, 41 (02) : 91 - 97
  • [3] Optimisation of the selectivity of a pulsed flame photometric detector for unknown compound screening
    Le Harle, JP
    Bellier, B
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) : 124 - 130
  • [4] A MODIFIED FLAME PHOTOMETRIC DETECTOR
    DALE, WE
    HUGHES, CC
    JOURNAL OF GAS CHROMATOGRAPHY, 1968, 6 (12): : 603 - &
  • [5] SELECTIVITY OF FLAME PHOTOMETRIC DETECTOR
    SEVCIK, J
    PHUONGTHAO, NT
    CHROMATOGRAPHIA, 1975, 8 (10) : 559 - 562
  • [6] QUENCHING IN THE FLAME PHOTOMETRIC DETECTOR
    AUE, WA
    SUN, XY
    JOURNAL OF CHROMATOGRAPHY, 1993, 641 (02): : 291 - 299
  • [7] TOTAL SULFUR AEROSOL DETECTION WITH AN ELECTROSTATICALLY PULSED FLAME PHOTOMETRIC DETECTOR SYSTEM
    KITTELSON, DB
    VERMEERSCH, M
    LINNE, M
    DORMAN, F
    PUI, D
    LIU, B
    WHITBY, K
    MCKENZIE, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1977, 173 (MAR20): : 42 - 42
  • [8] TOTAL SULFUR AEROSOL CONCENTRATION WITH AN ELECTROSTATICALLY PULSED FLAME PHOTOMETRIC DETECTOR SYSTEM
    KITTELSON, DB
    MCKENZIE, R
    VERMEERSCH, M
    DORMAN, F
    PUI, D
    LINNE, M
    LIU, B
    WHITBY, K
    ATMOSPHERIC ENVIRONMENT, 1978, 12 (1-3) : 105 - 111
  • [9] GC Analysis of Sulfur Components in Propylene Using a Pulsed Flame Photometric Detector
    Jacobse, Helena
    AMERICAN LABORATORY, 2011, 43 (07) : 17 - 17