CAPILLARY ELECTROCHROMATOGRAPHY OF SMALL MOLECULES IN POLYACRYLAMIDE GELS WITH ELECTROOSMOTIC FLOW

被引:106
|
作者
FUJIMOTO, C [1 ]
KINO, J [1 ]
SAWADA, H [1 ]
机构
[1] TOYOHASHI UNIV TECHNOL, DEPT MAT SCI, TOYOHASHI, AICHI 441, JAPAN
关键词
D O I
10.1016/0021-9673(95)00651-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditionally, polyacrylamide gels have been used as sieving media for the separation of macromolecules such as proteins and polynucleotides. Since these analytes are electrically charged, they can migrate under an applied electric field. In an attempt to separate uncharged analytes, acrylamide (AA)-2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) copolymers and AA-N,N'-methylenebisacrylamide (BIS)-AMPS copolymers were prepared. These copolymers are dear, UV-transparent gels and give electroosmosis due to the dissociation of the sulfo group. The preparation of the new gels in capillary tubes yielded the separation of comparatively small molecules, which is probably based on a molecular sieving effect.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 50 条
  • [1] Enhancement of electroosmotic flow in capillary electrochromatography
    Wen, E
    Rathore, AS
    Horváth, C
    ELECTROPHORESIS, 2001, 22 (17) : 3720 - 3727
  • [2] Characterisation of electroosmotic flow in capillary electrochromatography columns
    Dearie, HS
    Spikmans, V
    Smith, NW
    Moffatt, F
    Wren, SAC
    Evans, KP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 929 (1-2) : 123 - 131
  • [3] Capillary electrochromatography: theories on electroosmotic flow in porous media
    Rathore, AS
    Horvath, C
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 185 - 195
  • [4] Capillary electrochromatography with segmented capillaries for controlling electroosmotic flow
    Yang, CM
    El Rassi, Z
    ELECTROPHORESIS, 1999, 20 (01) : 18 - 23
  • [5] Theory of electroosmotic flow, retention and separation efficiency in capillary electrochromatography
    Rathore, AS
    ELECTROPHORESIS, 2002, 23 (22-23) : 3827 - 3846
  • [6] Modeling interparticle and intraparticle (perfusive) electroosmotic flow in capillary electrochromatography
    Vallano, PT
    Remcho, VT
    ANALYTICAL CHEMISTRY, 2000, 72 (18) : 4255 - 4265
  • [7] Stationary phase structures enhancing electroosmotic flow in capillary electrochromatography
    Tanigawa, T
    Nakagawa, T
    Kimata, K
    Nagayama, H
    Hosoya, K
    Tanaka, N
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 299 - 305
  • [8] Ability of porous graphitic carbon to support electroosmotic flow in capillary electrochromatography
    Al Rifafï, R
    Demesmay, C
    Rocca, JL
    JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) : 177 - 186
  • [9] Preparation and characterization of monolithic columns for capillary electrochromatography with weak electroosmotic flow
    Zhang, LY
    Ping, GC
    Zhang, LH
    Zhang, WB
    Zhang, YK
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (3-4) : 331 - 336
  • [10] Enantiomeric separations by capillary electrochromatography with charged polyacrylamide gels incorporating chiral selectors
    Koide, T
    Ueno, K
    ANALYTICAL SCIENCES, 2000, 16 (10) : 1065 - 1070