ACCURACY OF ADRENAL BIOPSY GUIDED BY ULTRASOUND AND CT

被引:1
|
作者
TIKKAKOSKI, T
TAAVITSAINEN, M
PAIVANSALO, M
LAHDE, S
APAJASARKKINEN, M
机构
关键词
ADRENAL GLAND; BIOPSY; NEOPLASMS; US STUDIES; CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We reviewed the results of fine needle biopsy of the adrenal glands guided by ultrasonography or CT in 56 patients. The final diagnoses, obtained at operation, autopsy or follow-up were: metastasis (n = 22), adenoma (n = 21), adrenal cyst (n = 6), hematoma (n = 3), lymphoma (n = 1), pheochromocytoma (n = 1), lymph node (n = 1), and amyloid mass (n = 1). Sufficient cytologic material was obtained in 96.4% (54/56). The overall accuracy to differentiate benign from malignant disease was 85.7% (48/56), 2 were false-negative, one was false-positive. The biopsy was inconclusive ("possibly malignant") in 3 patients, 2 of whom had an additional cutting needle biopsy yielding a correct positive finding. No complications occurred. We conclude that in disseminated malignant disease with suspected adrenal metastases diagnostic results can be obtained with guided fine needle biopsy. Biopsy in primary adrenal lesions is helpful, especially if the aspirate of the lesion turns out to be composed of something other than adrenal cells.
引用
收藏
页码:371 / 374
页数:4
相关论文
共 50 条
  • [1] CT-GUIDED ADRENAL BIOPSY - ACCURACY, SAFETY, AND INDICATIONS
    BERNARDINO, ME
    WALTHER, MM
    PHILLIPS, VM
    GRAHAM, SD
    SEWELL, CW
    GEDGAUDASMCCLEES, K
    BAUMGARTNER, BR
    TORRES, WE
    ERWIN, BC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (01) : 67 - 69
  • [2] Maximising the yield: CT-guided versus ultrasound-guided biopsy of renal and adrenal lesions
    Demkiw, S.
    Lavoipierre, A.
    Ryan, A.
    Moon, D.
    Frydenberg, M.
    Murphy, D.
    Austin, K.
    BJU INTERNATIONAL, 2015, 115 : 71 - 72
  • [3] Unenhanced CT, MR imaging, and CT-guided biopsy in the evaluation of adrenal masses: Assessment of accuracy and costs
    Schwartz, LH
    Panicek, DM
    Ginsberg, MS
    Hilton, S
    Brown, KT
    Getrajdman, GI
    RADIOLOGY, 1996, 201 : 322 - 322
  • [4] Intravascular Ultrasound-Guided Transvenous Biopsy of Retroperitoneal Lymph Nodes: Diagnostic Accuracy and Safety Compared with CT-Guided Percutaneous Biopsy
    Buchholz, Joseph
    Cline, Brendan C.
    Martin, Jonathan G.
    Kim, Charles Y.
    Ronald, James
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04) : 710 - 715
  • [5] Accuracy of CT-guided biopsy of musculoskeletal neoplasms
    Dupuy, DE
    Rosenberg, AE
    Punyaratabandhu, T
    Mankin, HJ
    Tan, MH
    RADIOLOGY, 1996, 201 : 531 - 531
  • [6] ULTRASOUND-GUIDED VERSUS CT-GUIDED STEREOTAXIC BIOPSY
    TSUTSUMI, Y
    JOURNAL OF NEUROSURGERY, 1987, 66 (05) : 788 - 788
  • [7] Pleural Ultrasound Post CT-Guided Biopsy
    Bardel, C.
    Golhen, H.
    Vergnenegre, C.
    Raherison, C.
    Grassion, L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [8] CT guided adrenal biopsy: Retrospective analysis of 44 procedures
    Mesurolle, B
    AricheCohen, M
    Tardivon, A
    Gilles, R
    Couanet, D
    Vanel, D
    JOURNAL DE RADIOLOGIE, 1996, 77 (01): : 17 - 21
  • [9] Gantry angulation in CT-guided percutaneous adrenal biopsy
    Hussain, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 537 - 539
  • [10] Audit of accuracy of ultrasound-guided axillary core biopsy
    A Anand
    R Henderson
    Breast Cancer Research, 13