CCDS AS LOW-ENERGY X-RAY-DETECTORS .2. TECHNICAL ASPECTS

被引:51
|
作者
VARIDEL, D
BOURQUIN, JP
BOVET, D
FIORUCCI, G
SCHENKER, D
机构
[1] Institut de Physique de l'Université
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1990年 / 292卷 / 01期
关键词
D O I
10.1016/0168-9002(90)91743-U
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The technical aspects of a command and readout system for commercially available X-ray charge-coupled devices (CCDs) is described in detail, including handling of noise problems, interfacing (CAMAC) and X-ray identification by software. Some of the problems encountered and their solution have been emphasized. © 1990.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 50 条
  • [1] CCDS AS LOW-ENERGY X-RAY-DETECTORS .1. GENERAL DESCRIPTION
    FIORUCCI, G
    BOURQUIN, JP
    BOVET, D
    BOVET, E
    EGGER, JP
    HECHE, C
    NUSSBAUM, C
    SCHENKER, D
    VARIDEL, D
    VUILLEUMIER, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (01): : 141 - 146
  • [2] CCDS AS X-RAY-DETECTORS IN A HIGH RADIATION ENVIRONMENT
    SIGG, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (01): : 107 - 114
  • [3] HIGH-RESOLUTION, LOW-ENERGY AVALANCHE PHOTODIODE X-RAY-DETECTORS
    FARRELL, R
    VANDERPUYE, K
    ENTINE, G
    SQUILLANTE, MR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 144 - 147
  • [4] MEASUREMENT OF THE LOW-ENERGY TAIL SPECTRA ADJACENT TO THE X-RAY PHOTOPEAK IN SI(LI) X-RAY-DETECTORS
    SHIMA, K
    NAGAI, S
    MIKUMO, T
    YASUMI, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (03): : 515 - 519
  • [5] X-RAY-DETECTORS
    BENTLEY, J
    ULTRAMICROSCOPY, 1989, 28 (1-4) : 211 - 212
  • [6] ENERGY AND TIME RESPONSE OF CCD X-RAY-DETECTORS
    LUMB, DH
    NOUSEK, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1379 - 1383
  • [7] X-RAY-DETECTORS - A REVIEW
    FRASER, GW
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 50 - 57
  • [8] X-RAY-DETECTORS AND SPECTROMETERS
    LYMAN, CE
    WILLIAMS, DB
    GOLDSTEIN, JI
    ULTRAMICROSCOPY, 1989, 28 (1-4) : 137 - 149
  • [9] CHARGE DIFFUSION EFFECTS IN CCD X-RAY-DETECTORS .2. EXPERIMENTAL RESULTS
    LUMB, DH
    HOPKINSON, GR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (03): : 431 - 438
  • [10] THE EXOSAT IMAGING X-RAY-DETECTORS
    MASON, IM
    BRANDUARDIRAYMONT, G
    CULHANE, JL
    CORBET, RHD
    IVES, JC
    SANFORD, PW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 795 - 800