Purpose: Stereotactic Radiosurgery (SRS) can utilize different techniques. For small target SRS, the selections of the apertures of cone or MLC field influence the treatment significantly. In this study, while the aperture of the MLC and cone field vary, the dosimetric characteristics of the two techniques are compared for SRS of small targets which are in the favor of magnifying the dosimetric effect. Methods and Materials: An anthropomorphic phantom was used to simulate the patient with an arbitrary drawn cranial target, whose volume is equivalent to a 4 millimeter sphere. Single 360 ARC plans were generated with Eclipse external beam and cone based treatment planning system from Varian Medical System. For MLC based plan, the apertures fit to the structure with circle margins varying with 2mm, 3mm, 4mm, 5mm and 6mm. These setups were compared with the cones being selected to be 5mm, 10mm, 12mm, 14mm and 16mm in diameter. For the MLC based plan, the leaf-edge-contour meet points were selected to be in the middle. Jaw positions were used both recommend and optimize options, which are provided by the treatment planning system. Mean dose was treated as the prescription dose. Comparison of the two planning techniques was carried out using 12Gy Volume (V12Gy) from dose-volume histogram (DVH), maximum dose to the prescription dose ratio (MDPD), ratio PITV (PIV/TV), radiation conformity index (RCI), which is defined to be TVPIV/PIV, and an integrated conformity index (TVPIV2/(TVxPIV)), where PIV is the prescription isodose surface volume, TV is target volume, and TV PIV is the intersection of TV and the PIV. Results: For the apertures used for this study, while MLC and cone based plans were compared by prescribed at 20Gy, the V12Gy ranges were from 1.0cc to 5.3cc with average at 3.3cc, and 0.1cc to 3.2cc with average value at 1.5cc. The variations of MDPD were 9% with average value at 1.04, and 12% with average at 1.03. The varying ranges of PITV were 35% with average value at 0.80, and 17% with average value at 0.54. Integrated conformity index (ICI) variations were up to 45% with average value at 0.34, and at the level of the 7% with average value at 0.42. Conclusions: For small target SRS, there are larger variations in V12Gy, PITV, and ICI in MLC based plan than those of cone based plan, while the difference is not significant for MDPD in both settings at the selected aperture sizes. These information could help in decision making through sensitivity study while sufficient clinical outcome information were available. The multiple ARC treatment plan and the clinical reality of algorithm for small aperture also need further investigation.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 50 条
  • [1] Therapeutic use of Linac-based SRS in the treatment of malignant spasticity
    Nicosia, L.
    Romanelli, P.
    Ferrari, F.
    Marchioretto, F.
    Zamperini, M.
    De Simone, A.
    Ruggieri, R.
    Alongi, F.
    Avesani, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S637 - S638
  • [2] Target Localization Error Estimation in Linac Based SRS Treatment
    Gholami, S.
    Narayanasamy, G.
    Kalantari, F.
    Sabouri, P.
    Su, Z.
    MEDICAL PHYSICS, 2022, 49 (06) : E383 - E384
  • [3] A New Method for Optimizing Radiation Isocenter for Linac-Based SRS
    Hancock, S.
    Hyer, D.
    Nixon, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3343 - 3343
  • [4] Repeated SRS with linac-based monoisocentric technique in recurrent intracranial metastases
    Nicosia, L.
    Giaj-Levra, N.
    Mazzola, R.
    Ricchetti, F.
    Pastorello, E.
    Rigo, M.
    Figlia, V.
    Ruggieri, R.
    Alongi, F.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S906 - S907
  • [5] Dose Verification for Linac-Based SRS Commissioning and Patient Specific QA
    Wu, J.
    Wu, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3799 - 3799
  • [6] Linac-based stereotactic radiosurgery (SRS) in the treatment of refractory trigeminal neuralgia: Detailed description of SRS procedure and reported clinical outcomes
    Pokhrel, Damodar
    Sood, Sumit
    McClinton, Christopher
    Saleh, Habeeb
    Badkul, Rajeev
    Jiang, Hongyu
    Stepp, Timothy
    Camarata, Paul
    Wang, Fen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 136 - 143
  • [7] Linac-Based Stereotactic Radiosurgery (SRS) in the Treatment of Trigeminal Neuralgia: Detailed Description of SRS Procedural Technique and Reported Clinical Outcomes
    Pokhrel, D.
    Sood, S.
    Badkul, R.
    Jiang, H.
    Stepp, T.
    Camarata, P.
    Wang, F.
    MEDICAL PHYSICS, 2016, 43 (06) : 3612 - 3613
  • [8] Single Fraction LINAC-Based SRS Re-Treatment of Brain Metastases Using Conservative Doses
    Cummings, M. A.
    Usuki, K. Y.
    Hardy, S.
    Milano, M. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E566 - E566
  • [9] Dosimetric Comparison of Linac-Based SRS and Gamma Knife Plans for Arteriovenous Malformations
    Garcia, B.
    Calugaru, E.
    Chitti, B.
    Delacruz, B.
    Goenka, A.
    Chang, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E385 - E385
  • [10] Modeling the Loss of Tumor Control Probability (TCP) Due to Small Geometrical Deviations of LINAC-Based Stereotactic Radiosurgery (SRS)
    Patel, A. J.
    Papanikolaou, N.
    Gutierrez, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S727 - S727