CARDIAC BLOOD-POOL SCINTIGRAPHY IN RATS AND HAMSTERS - COMPARISON OF 5 RADIOPHARMACEUTICALS AND 3 PINHOLE COLLIMATOR APERTURES

被引:0
|
作者
PIERI, P
FISCHMAN, AJ
AHMAD, M
MOORE, RH
CALLAHAN, RJ
STRAUSS, HW
机构
[1] MASSACHUSETTS GEN HOSP, DIV NUCL MED, 55 FRUIT ST, BOSTON, MA 02114 USA
[2] MASSACHUSETTS GEN HOSP, DEPT RADIOL, BOSTON, MA 02114 USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA 02115 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Preclinical evaluation of cardiac drugs may require evaluation of cardiac function in intact animals. To optimize the quality of radionuclide measurements of ventricular function in small animals, a comparison was made of gated blood-pool scans recorded with five blood-pool radiopharmaceuticals (99mTc-labeled human polyclonal IgG, 99mTc-human serum albumin labeled by two methods, and red blood cells radiolabeled with 99mTc via in vivo and in vitro methods) in rats and three pinhole apertures in hamsters. The quality of the radiopharmaceuticals was evaluated by comparing count density ratios (LV/BACKGROUND and LV/LIVER) and ejection fractions recorded with each agent. The edge definition of the left ventricle and count rate performance of the 1-, 2-, and 3-mm apertures was evaluated in hamsters. In general, the images obtained with the radiolabeled cells were superior to those obtained with the labeled proteins and no significant differences between the protein preparations were detected. Left ventricular ejection fractions calculated with all five radiopharmaceuticals were not significantly different. The best quality images were obtained with the 1-mm pinhole collimator. Ejection fraction and acquisition time were inversely related to aperture size. A good compromise between resolution and sensitivity was obtained with the 2-mm pinhole collimator.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 23 条
  • [1] CAVERNOUS HEMANGIOMA OF THE LIVER - EVALUATION OF BLOOD-POOL SCINTIGRAPHY IN COMPARISON WITH CT AND SONOGRAPHY
    SCHREYER, T
    KRAUS, W
    KESSEL, F
    FISCHER, S
    SCHWEDEN, F
    HAHN, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A8 - A8
  • [2] INVIVO COMPARISON OF COPPER BLOOD-POOL AGENTS - POTENTIAL RADIOPHARMACEUTICALS FOR USE WITH COPPER-62
    MATHIAS, CJ
    WELCH, MJ
    GREEN, MA
    DIRIL, H
    MEARES, CF
    GROPLER, RJ
    BERGMANN, SR
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (03) : 475 - 480
  • [3] DETECTION OF CORONARY-ARTERY DISEASE WITH GATED CARDIAC BLOOD-POOL SCINTIGRAPHY - COMPARISON OF COLD PRESSOR TEST AND DYNAMIC EXERCISE
    ROOTWELT, K
    ERIKSSEN, J
    NITTERHAUGE, S
    THAULOW, E
    CLINICAL PHYSIOLOGY, 1982, 2 (06): : 459 - 465
  • [4] 3-DIMENSIONAL DISPLAY OF GATED CARDIAC BLOOD-POOL STUDIES
    MILLER, TR
    WALLIS, JW
    SAMPATHKUMARAN, KS
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (12) : 2036 - 2041
  • [5] COMPARISON OF PROTOCOLS IN THE MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION IN GATED BLOOD-POOL SCINTIGRAPHY
    YOUNG, KC
    RAILTON, R
    BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648): : 1091 - 1093
  • [6] COMPARISON OF ULTRASOUND AND BLOOD-POOL SCINTIGRAPHY IN THE DIAGNOSIS OF LOWER-LIMB DEEP VENOUS THROMBOSIS
    ROBERTSON, PL
    BERLANGIERI, SU
    GOERGEN, SK
    WAUGH, JR
    KALFF, V
    STEVENS, SN
    HICKS, RJ
    FABINY, RPJ
    UGONI, A
    KELLY, MJ
    CLINICAL RADIOLOGY, 1994, 49 (06) : 382 - 390
  • [7] Comparison of technetium-99m IgG with technetium-99m red blood cells labeling in cardiac blood-pool scintigraphy: a preliminary study
    Javadi, Hamid
    Asli, Isa Neshandar
    Semnani, Shahriar
    Jallalat, Sara
    Ansari, Mojtaba
    Amini, Abdullatif
    Barekat, Maryam
    Assadi, Majid
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2011, 14 (01): : 30 - 33
  • [8] COMPARISON OF FIXED AND VARIABLE TEMPORAL RESOLUTION METHODS FOR CREATING GATED CARDIAC BLOOD-POOL IMAGE SEQUENCES
    BACHARACH, SL
    BONOW, RO
    GREEN, MV
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (01) : 38 - 42
  • [9] CARDIAC BLOOD-POOL SCINTIGRAPHY USING TECHNETIUM-99M DTPA-HSA - COMPARISON WITH INVIVO TECHNETIUM-99M RBC LABELING
    NISHIMURA, T
    HAMADA, S
    HAYASHIDA, K
    UEHARA, T
    KATABUCHI, T
    HAYASHI, M
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (10) : 1713 - 1717
  • [10] VISUALIZING CARDIAC BLOOD POOL - COMPARISON OF 3 LABELING METHODS
    NEUMANN, P
    SCHICHA, H
    SCHURNBRAND, P
    BAHRE, M
    EMRICH, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1983, 8 (11): : 463 - 466