Signal intensity and T2 time of extraocular muscles in assessment of their physiological status in MR imaging in healthy subjects

被引:7
|
作者
Pajak, Michal [1 ]
Loba, Piotr [1 ]
Wieczorek-Pastusiak, Julia [1 ]
Antosik-Biernacka, Aneta [1 ]
Stefanczyk, Ludomir [1 ]
Majos, Agata [1 ]
机构
[1] Diagnost Imaging Med Univ, Dept Radiol, Kopcinskiego 22 St, PL-90153 Lodz, Poland
关键词
extraocular muscles; signal intensity; T2; time; reference values;
D O I
10.12659/PJR.883622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Lack of standardised orbital MR protocols leads to a situation, when each institution/centre may arbitrarily choose sequence parameters. Therefore, the results obtained and published by the authors may not be compared freely, and what is most important may not be considered fully reliable. Signal intensity (IS) and T2 time (T2) are important parameters in estimation of inflammatory processes of extraocular muscles in the clinical practice. The aim of this study was to determine the reference values (i.e. cut-off values) for absolute signal intensity and T2 relaxation time in healthy subjects, their relativised values to white matter (WM) and temporal muscles (TM) and to evaluate the correlation between those parameters. Material/Methods: The orbital examination was performed in healthy volunteers according to the protocol prepared in the Radiology-Imaging Diagnostic Department of the Medical University of Lodz for patients with suspected/diagnosed thyroid orbitopathy. Using two of the standard sequences IS and T2 time were calculated for the muscles and two relativisation tissues in realtion to WM and TM. Subsequently cut-off values for healthy volunteers were calculated. Results: The differences between muscles for IS, IS MAX, IS/TM, IS/WM, IS MAX/TM, IS MAX/WM and T2 MAX/WM were not statistically significant. Therefore one cut-off value of these parameters for all the rectus muscles was calculated. T2-relaxation time and T2 relativised to white matter had to be calculated separately for each muscle. Conclusions: No statistical correlation was found between IS and T2-time for extraocular muscles in healthy volunteers. We calculated the reference ranges (cut-off values) for absolute IS and T2-time values and relativised parameters. In the clinical practice the objectification of IS and T2-time values should be done to WM, than to IS or T2 of the temporal muscle. The T2 MAX/WM seems to have the highest clinical utility for the assessment of the pathophysiological status of extraocular muscles.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [1] FOCI OF INCREASED T2 SIGNAL INTENSITY ON BRAIN MR SCANS OF HEALTHY ELDERLY SUBJECTS
    HENDRIE, HC
    FARLOW, MR
    AUSTROM, MG
    EDWARDS, MK
    WILLIAMS, MA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 703 - 707
  • [2] FOCI OF INCREASED T2 SIGNAL INTENSITY IN MR IMAGES OF HEALTHY ELDERLY SUBJECTS - A FOLLOW-UP-STUDY
    AUSTROM, MG
    THOMPSON, RF
    HENDRIE, HC
    NORTON, J
    FARLOW, MR
    EDWARDS, MK
    DEAN, R
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1990, 38 (10) : 1133 - 1138
  • [3] Meniscal Measurements of T1ρ and T2 at MR Imaging in Healthy Subjects and Patients with Osteoarthritis
    Rauscher, Isabel
    Stahl, Robert
    Cheng, Jonathan
    Li, Xiaojuan
    Huber, Markus B.
    Luke, Anthony
    Majumdar, Sharmila
    Link, Thomas M.
    RADIOLOGY, 2008, 249 (02) : 591 - 600
  • [4] MR imaging assessment of myocardial edema with T2 mapping
    Montant, P.
    Sigovan, M.
    Revel, D.
    Douek, P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (09) : 885 - 890
  • [5] EXTRAOCULAR-MUSCLES IN GRAVES OPHTHALMOPATHY - USEFULNESS OF T2 RELAXATION-TIME MEASUREMENTS
    OHNISHI, T
    NOGUCHI, S
    MAURAKAMI, N
    TAJIRI, J
    HARAO, M
    KAWAMOTO, H
    HOSHI, H
    JINNOUCHI, S
    FUTAMI, S
    NAGAMACHI, S
    WATANABE, K
    RADIOLOGY, 1994, 190 (03) : 857 - 862
  • [6] Integrated treadmill stress testing and MR relaxometry (T1, T2, T2*): response in healthy calf muscles
    Juliet Varghese
    Debbie Scandling
    Jason Craft
    Subha V Raman
    Orlando P Simonetti
    Georgeta Mihai
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [7] Objective measurement of minimal fat in normal skeletal muscles of healthy children using T2 relaxation time mapping (T2 maps) and MR spectroscopy
    Kim, Hee Kyung
    Serai, Suraj
    Merrow, Arnold C.
    Wang, Lily
    Horn, Paul S.
    Laor, Tal
    PEDIATRIC RADIOLOGY, 2014, 44 (02) : 149 - 157
  • [8] Objective measurement of minimal fat in normal skeletal muscles of healthy children using T2 relaxation time mapping (T2 maps) and MR spectroscopy
    Hee Kyung Kim
    Suraj Serai
    Arnold C. Merrow
    Lily Wang
    Paul S. Horn
    Tal Laor
    Pediatric Radiology, 2014, 44 : 149 - 157
  • [9] Influence of hydration status on cardiovascular magnetic resonance myocardial T1 and T2 relaxation time assessment: an intraindividual study in healthy subjects
    Luetkens, Julian A.
    Voigt, Marilia
    Faron, Anton
    Isaak, Alexander
    Mesropyan, Narine
    Dabir, Darius
    Sprinkart, Alois M.
    Pieper, Claus C.
    Chang, Johannes
    Attenberger, Ulrike
    Kuetting, Daniel
    Thomas, Daniel
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [10] Influence of hydration status on cardiovascular magnetic resonance myocardial T1 and T2 relaxation time assessment: an intraindividual study in healthy subjects
    Julian A. Luetkens
    Marilia Voigt
    Anton Faron
    Alexander Isaak
    Narine Mesropyan
    Darius Dabir
    Alois M. Sprinkart
    Claus C. Pieper
    Johannes Chang
    Ulrike Attenberger
    Daniel Kuetting
    Daniel Thomas
    Journal of Cardiovascular Magnetic Resonance, 22