RENAL-CANCER STAGING - COMPARISON OF CONTRAST-ENHANCED CT AND GADOLINIUM-ENHANCED FAT-SUPPRESSED SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING

被引:55
|
作者
SEMELKA, RC
SHOENUT, JP
MAGRO, CM
KROEKER, MA
MACMAHON, R
GREENBERG, HM
机构
[1] Departments of Radiology, St Boniface General Hospital MRI Facility and the University of Manitoba, Winnipeg, Manitoba
[2] Departments of Pathology, St Boniface General Hospital MRI Facility and the University of Manitoba, Winnipeg, Manitoba
[3] Departments of Surgery, St Boniface General Hospital MRI Facility and the University of Manitoba, Winnipeg, Manitoba
来源
关键词
COMPARATIVE STUDIES; CONTRAST ENHANCEMENT; FAT SUPPRESSION; GADOLINIUM; KIDNEY; CYSTS; KIDNEY NEOPLASMS; DIAGNOSIS; STAGING;
D O I
10.1002/jmri.1880030408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fifty-three consecutive patients with 61 solid or complex non-fat-containing renal masses compatible with renal cancer were examined with contrast-enhanced computed tomography (CT) and magnetic resonance (MR) imaging with pre- and postcontrast FLASH (fast low-angle shot) and fat-suppressed spin-echo sequences. CT and MR imaging were performed within a 1-month interval. CT and MR images were prospectively interpreted. Tumor detection and staging were determined in all patients. CT and MR imaging enabled detection of 54 and 58 of 61 renal tumors, respectively. CT and MR imaging showed 34 and 35 of 38 histologically proved renal tumors, respectively, in 31 patients. Tumor size on CT and MR images demonstrated good correlation and correlated well with the size of pathologic specimens of 34 of 38 resected tumors detected with CT and MR imaging (r = .99). Of the 31 tumors in 31 patients who underwent surgical resection, 24 were correctly staged with CT and 29 with MR imaging. CT and MR imaging both enabled correct staging of four of five additional tumors with biopsy proof of tumor stage. A moderate difference in staging was observed between CT and MR imaging (P = .05). CT showed 13 and MR imaging 15 of 15 tumor thrombi. CT and MR imaging both showed 11 of 11 cases of adenopathy. The results suggest that MR imaging is moderately better than CT for the detection and staging of renal cancer.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [1] DYNAMIC GRADIENT-ECHO AND FAT-SUPPRESSED SPIN-ECHO CONTRAST-ENHANCED MRI OF THE BREAST
    KERSLAKE, RW
    CARLETON, PJ
    FOX, JN
    IMRIE, MJ
    COOK, AM
    READ, JR
    BOWSLEY, SJ
    BUCKLEY, DL
    HORSMAN, A
    CLINICAL RADIOLOGY, 1995, 50 (07) : 440 - 454
  • [2] Crohn disease with endoscopic correlation: Single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging
    Low, RN
    Sebrechts, CP
    Politoske, DA
    Bennett, MT
    Flores, S
    Snyder, RJ
    Pressman, JH
    RADIOLOGY, 2002, 222 (03) : 652 - 660
  • [3] Gradient-echo versus fat-suppressed fast spin-echo MR imaging of rotator cuff tears
    Sahin-Akyar, G
    Miller, TT
    Staron, RB
    McCarthy, DM
    Feldman, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 223 - 227
  • [4] MR dynamic Gadolinium-enhanced fast multiplanar spoiled gradient-echo and spin-echo T1-weighted fat-suppressed techniques in diagnosis of pancreatic carcinoma
    Meng-Su Zeng
    Fu-Hua Yan
    Kang-Rong Zhou
    Zhu-Wan Chen
    Ji-Zhang Sun
    Cai-Zhong Chen
    Wei-Bing Shi From the Dapartment of Radiology
    Hepatobiliary & Pancreatic Diseases International, 2002, (02) : 294 - 298
  • [5] Comparison of dynamic contrast-enhanced gradient-echo and spin-echo sequences in MR of head and neck neoplasms
    Escott, EJ
    Rao, VM
    Ko, WD
    Guitierrez, JE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (08) : 1411 - 1419
  • [6] MR-IMAGING OF THE BRAIN - COMPARISON OF GRADIENT-ECHO AND SPIN-ECHO PULSE SEQUENCES
    PUI, MH
    FOK, ECM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 959 - 962
  • [7] INTRAHEPATIC CHOLANGIOCARCINOMA - SPIN-ECHO AND CONTRAST-ENHANCED DYNAMIC MR-IMAGING
    FAN, ZM
    YAMASHITA, Y
    HARADA, M
    BABA, Y
    YAMAMOTO, H
    MATSUKAWA, T
    ARAKAWA, A
    MIYAZAKI, T
    TAKAHASHI, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (02) : 313 - 317
  • [8] CARDIAC MASSES - SIGNAL INTENSITY FEATURES ON SPIN-ECHO, GRADIENT-ECHO, GADOLINIUM-ENHANCED SPIN-ECHO, AND TURBOFLASH IMAGES
    SEMELKA, RC
    SHOENUT, JP
    WILSON, ME
    PELLECH, AE
    PATTON, JN
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 415 - 420
  • [9] ENDOMETRIOSIS - APPEARANCE AND DETECTION WITH CONVENTIONAL AND CONTRAST-ENHANCED FAT-SUPPRESSED SPIN-ECHO TECHNIQUES
    ASCHER, SM
    AGRAWAL, R
    BIS, KG
    BROWN, ED
    MAXIMOVICH, A
    MARKHAM, SM
    PATT, RH
    SEMELKA, RC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 251 - 257
  • [10] RENAL LESIONS - CONTROLLED COMPARISON BETWEEN CT AND 1.5-T MR IMAGING WITH NONENHANCED AND GADOLINIUM-ENHANCED FAT-SUPPRESSED SPIN-ECHO AND BREATH-HOLD FLASH TECHNIQUES
    SEMELKA, RC
    SHOENUT, JP
    KROEKER, MA
    MACMAHON, RG
    GREENBERG, HM
    RADIOLOGY, 1992, 182 (02) : 425 - 430