CORRELATION BETWEEN COMPUTER-ASSISTED FEMORAL ARTERIOGRAPHY AND PHYSIOLOGICAL TESTS IN HYPERCHOLESTEROLEMIC PATIENTS - A METHODOLOGICAL STUDY WITH SPECIAL REFERENCE TO CLINICAL-TRIALS

被引:4
|
作者
NILSSON, S
KAIJSER, L
ERIKSON, U
JOHANSSON, J
WALLDIUS, G
机构
[1] KAROLINSKA HOSP,DEPT CLIN PHYSIOL,S-10401 STOCKHOLM 60,SWEDEN
[2] KAROLINSKA HOSP,KING GUSTAF V RES INST,S-10401 STOCKHOLM 60,SWEDEN
[3] HUDDINGE SJUKHUS,STOCKHOLM,SWEDEN
来源
CLINICAL PHYSIOLOGY | 1992年 / 12卷 / 01期
关键词
COMPUTER; FEMORAL ARTERIOGRAPHY; PHYSIOLOGY; ATHEROSCLEROSIS; HYPERCHOLESTEROLEMIA; CLINICAL TRIAL;
D O I
10.1111/j.1475-097X.1992.tb00293.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The validity of computer-assisted femoral arteriography, for the study of regression/progression of atherosclerosis in follow-up clinical trials, was investigated by comparison with routine physiological estimates of peripheral circulatory function. Thus, in 114 hypercholesterolaemic patients, the results of aorto-femoral arteriography were compared with those of leg segmental blood pressure measurement, oscillometry, digital pulse plethysmography, and bicycle and treadmill exercise tests. In 107 patients, 18 with symptoms of peripheral vascular disease (PVD) and 89 asymptomatic, magnification arteriograms of a 20 cm segment of the right or left superficial femoral artery were obtained. These arteriograms were digitized and the following variables were calculated: arterial lumen volume (corrected for body size), per cent stenosis, and edge roughness. The correlation between arteriographic and physiological variables was investigated with a linear regression model, taking into account the possible interaction with sex, and presence or absence of symptoms of PVD. Lumen volume correlated significantly with all five physiological variables, and per cent stenosis correlated significantly with four of the physiological variables. For the roughness measure, however a significant correlation was found only with plethysmography. By using logistic multiple regression analysis linear functions of physiological variables were constructed to detect ilio-femoral arterial occlusion. The sensitivity/specificity for detection of right-sided, left-sided, and bilateral occlusion was 0.83/0.98, 0.78/0.98, and 0.60/1.00 respectively (N = 108-111). Systolic blood pressure (ankle-arm ratio) was the single variable most closely correlated to the likelihood of arterial occlusions. It is concluded that arterial lumen volume and per cent stenosis, measured for the digitized femoral arteriogram, correlate well with physiological variables, which reflect the state of atherosclerosis both in the femoral arteries and in other arterial beds including the heart, and that routine physiological tests can be used to identify patients with arterial occlusions in the iliac and femoral arteries.
引用
收藏
页码:53 / 68
页数:16
相关论文
共 1 条
  • [1] Correlation Study Between Clinical Special Tests for Myelopathy and Static MRI Parameters in Patients of Malaysian Population Treated for Cervical Dysfunction
    Mohamad, Zamzuri Zakaria
    Sharifudin, Mohd Ariff
    Din, Hishamudin
    Abd Aziz, Azian
    Karupiah, Rajandra Kumar
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)