共 50 条
DYNAMIC GADOLINIUM-ENHANCED MR-IMAGING OF THE SPLEEN - NORMAL ENHANCEMENT PATTERNS AND EVALUATION OF SPLENIC LESIONS
被引:34
|作者:
MIROWITZ, SA
[1
]
BROWN, JJ
[1
]
LEE, JKT
[1
]
HEIKEN, JP
[1
]
机构:
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
来源:
关键词:
GADOLINIUM;
MAGNETIC RESONANCE (MR);
PULSE SEQUENCES;
RAPID IMAGING;
SPLEEN CYSTS;
SPLEEN;
LYMPHOMA;
HEMANGIOMA;
MR-STUDIES;
NEOPLASMS;
D O I:
10.1148/radiology.179.3.2027974
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
The authors studied the ability to improve detection of splenic lesions during suspended respiration with dynamic gadolinium-enhanced T1-weighted spin-echo magnetic resonance (MR) imaging. In the first phase of the study, normal splenic contrast material enhancement patterns were assessed in 10 control patients without splenic lesions. A heterogeneous signal intensity pattern was observed in 11 patients with splenic lesions during bolus injection of gadopentetate dimeglumine, with conversion to homogeneous enhancement 1 minute later. Mean splenic enhancement was 321% during bolus injection, with a rapid return toward baseline signal intensity thereafter. In the second phase, evaluation of 18 splenic lesions detected with contrast-enhanced computed tomography in 11 patients revealed that dynamic gadolinium-enhanced MR pulse sequences significantly improved lesion conspicuity and detectability compared with conventional T1- and T2-weighted pulse sequences. Contrast-to-artifact ratio measurements were 0.5, 3.7, and 9.3 for conventional T1-weighted, T2-weighted, and dynamic gadolinium-enhanced MR images, respectively.
引用
收藏
页码:681 / 686
页数:6
相关论文