RELIABILITY OF GRIP STRENGTH ASSESSMENT WITH THE COMPUTERIZED JAMAR DYNAMOMETER

被引:16
|
作者
NIEBUHR, BR [1 ]
MARION, R [1 ]
FIKE, ML [1 ]
机构
[1] TEXAS WOMANS UNIV, HOUSTON, TX 77030 USA
来源
关键词
FORCE; DATA REDUCTION; NORMAL SUBJECTS;
D O I
10.1177/153944929401400101
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J.A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip strength were followed. Both left and right hands were tested. We quantified three characteristics of the force curve: (a) the slope of the rise in force, (b) the maximal or peak force, and (c) the mean sustained force over the last 3 sec of a 5-sec contraction. Reliability was good with intraclass reliability coefficients ranging from .84 to .93. We conclude that the computerized Jamar will yield reliable measurement of grip strength if the instrument is calibrated properly and if standardized procedures for grip strength testing are followed.
引用
收藏
页码:3 / 18
页数:16
相关论文
共 50 条
  • [1] MEASUREMENT OF GRIP STRENGTH - VALIDITY AND RELIABILITY OF THE SPHYGMOMANOMETER AND JAMAR GRIP DYNAMOMETER
    HAMILTON, GF
    MCDONALD, C
    CHENIER, TC
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 215 - 219
  • [2] REVISED NORMATIVE VALUES FOR GRIP STRENGTH WITH THE JAMAR DYNAMOMETER
    Peters, M. J. H.
    van Nes, S., I
    Vanhoutte, E. K.
    Bakkers, M.
    van Doorn, P. A.
    Merkies, I. S. J.
    Faber, C. G.
    [J]. JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 : S107 - S108
  • [3] Revised normative values for grip strength with the Jamar dynamometer
    Peters, Martine J. H.
    van Nes, Sonja I.
    Vanhoutte, Els K.
    Bakkers, Mayienne
    van Doorn, Pieter A.
    Merkies, Ingemar S. J.
    Faber, Catharina G.
    [J]. JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2011, 16 (01) : 47 - 50
  • [4] Measuring Grip Strength in Older Adults: Comparing the Grip-ball With the Jamar Dynamometer
    Vermeulen, Joan
    Neyens, Jacques C. L.
    Spreeuwenberg, Marieke D.
    van Rossum, Erik
    Hewson, David J.
    de Witte, Luc P.
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2015, 38 (03) : 148 - 153
  • [5] Study of Reliability and Validity of the Load Cell-Type Hand Dynamometer Compared to the Jamar Dynamometer and the Number of Reliable Grip Strength Measurements
    Kanauchi, Yumiko
    Murase, Tsuyoshi
    Nishiwaki, Masao
    Odagiri, Masahiro
    Wanezaki, Yoshihiro
    Ishikawa, Hitoshi
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (05): : 562 - 572
  • [6] Parallel comparison of grip strength measures obtained with a MicroFET 4 and a jamar dynamometer
    Bohannon, RW
    [J]. PERCEPTUAL AND MOTOR SKILLS, 2005, 100 (03) : 795 - 798
  • [7] JAMAR DYNAMOMETER AND ADAPTED SPHYGMOMANOMETER FOR MEASURING GRIP STRENGTH IN PATIENTS WITH RHEUMATOID-ARTHRITIS
    AGNEW, PJ
    MAAS, F
    [J]. OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1991, 11 (05): : 259 - 270
  • [8] COMPARISON OF THE JAMAR DYNAMOMETER AND THE MARTIN VIGORIMETER FOR GRIP STRENGTH MEASUREMENTS IN A HEALTHY ELDERLY POPULATION
    DESROSIERS, J
    HEBERT, R
    BRAVO, G
    DUTIL, E
    [J]. SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1995, 27 (03): : 137 - 143
  • [9] Comparison of the BTE tech EVJ handgrip to the Jamar hand dynamometer for measuring grip strength
    Myers, Edwin J.
    Dominguez, David S.
    Guigliano, Melissa E.
    Mallory, Melissa G.
    [J]. TECHNOLOGY AND DISABILITY, 2021, 33 (03) : 221 - 227
  • [10] Reliability and validity of an electronic dynamometer for measuring grip strength
    Allen, Deborah
    Barnett, Fiona
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 258 - 264