Comparison of the Achilles tendon moment arms determined using the tendon excursion and three-dimensional methods

被引:5
|
作者
Hashizume, Satoru [1 ,2 ,3 ]
Fukutani, Atsuki [3 ,4 ]
Kusumoto, Kazuki [5 ]
Kurihara, Toshiyuki [6 ]
Yanagiya, Toshio [2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Human Informat Res Inst, Tokyo, Japan
[2] Juntendo Univ, Fac Hlth & Sports Sci, Chiba, Japan
[3] Japan Soc Promot Sci, Tokyo, Japan
[4] Ritsumeikan Univ, Res Org Sci & Technol, Kusatsu, Shiga, Japan
[5] Kurashiki Univ Sci & Arts, Fac Sci & Ind Technol, Okayama, Japan
[6] Ritsumeikan Univ, Fac Sport & Hlth Sci, Kusatsu, Shiga, Japan
来源
PHYSIOLOGICAL REPORTS | 2016年 / 4卷 / 19期
关键词
Magnetic resonance imaging; musculoskeletal model; triceps surae; ultrasonography;
D O I
10.14814/phy2.12967
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The moment arm of muscle-tendon force is a key parameter for calculating muscle and tendon properties. The tendon excursion method was used for determining the Achilles tendon moment arm (ATMA). However, the accuracy of this method remains unclear. This study aimed to investigate the magnitude of error introduced in determining the ATMA using the tendon excursion method by comparing it with the reference three-dimensional (3D) method. The tendon excursion method determined the ATMA as the ratio between the Achilles tendon displacement during foot rotation from 15 degrees of dorsiflexion to 15 degrees of plantarflexion and the joint rotation angle. A series of foot images was obtained at 15 degrees of dorsiflexion, the neutral position, and 15 degrees of plantarflexion. The 3D value of the ATMA was determined as the shortest distance between the talocrural joint axis and the line of action of the Achilles tendon force. The ATMA determined by the tendon excursion method was smaller by 3.8 mm than that determined using the 3D method. This error may be explained mainly by the length change in the Achilles tendon due to the change in the force applied to it, as passive plantarflexion torque was different by 11 Nm between 15 degrees of dorsiflexion and 15 degrees of plantarflexion. Furthermore, the ATMAs determined using the 3D and tendon excursion methods were significantly correlated but the coefficient of determination was not large (R-2 = 0.352). This result suggests that the tendon excursion method may not be feasible to evaluate the individual variability of the ATMA.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Achilles tendon moment arms: The importance of measuring at constant tendon load when using the tendon excursion method
    Olszewski, Katarzyna
    Dick, Taylor J. M.
    Wakeling, James M.
    JOURNAL OF BIOMECHANICS, 2015, 48 (06) : 1206 - 1209
  • [2] Reliability of Achilles Tendon Moment Arm Measured In Vivo Using Freehand Three-Dimensional Ultrasound
    Obst, Steven J.
    Barber, Lee
    Miller, Ashton
    Barrett, Rod S.
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (04) : 300 - 304
  • [3] Estimation of Tendon Moment Arms from Three-Dimensional Magnetic Resonance Images
    Wilson, David L.
    Zhu, Qian
    Duerk, Jeffrey L.
    Mansour, Joseph M.
    Kilgore, Kevin
    Crago, Patrick E.
    Annals of Biomedical Engineering, 27 (02): : 247 - 256
  • [4] Estimation of tendon moment arms from three-dimensional magnetic resonance images
    Wilson, DL
    Zhu, Q
    Duerk, JL
    Mansour, JM
    Kilgore, K
    Crago, PE
    ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (02) : 247 - 256
  • [5] Estimation of Tendon Moment Arms from Three-Dimensional Magnetic Resonance Images
    David L. Wilson
    Qian Zhu
    Jeffrey L. Duerk
    Joseph M. Mansour
    Kevin Kilgore
    Patrick E. Crago
    Annals of Biomedical Engineering, 1999, 27 : 247 - 256
  • [6] The contraction-induced increase in Achilles tendon moment arm: A three-dimensional study
    Hashizume, Satoru
    Iwanuma, Soichiro
    Akagi, Ryota
    Kanehisa, Hiroaki
    Kawakami, Yasuo
    Yanai, Toshimasa
    JOURNAL OF BIOMECHANICS, 2014, 47 (12) : 3226 - 3231
  • [7] Effects of Different Extents of Pulley Release on Tendon Excursion Efficiency and Tendon Moment Arms
    Lu, Szu-Ching
    Yang, Tai-Hua
    Kuo, Li-Chieh
    Jou, I-Ming
    Sun, Yung-Nien
    Su, Fong-Chin
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (02) : 224 - 228
  • [8] Three-dimensional reconstructions of the Achilles tendon insertion in man
    Milz, S
    Rufai, A
    Buettner, A
    Putz, R
    Ralphs, JR
    Benjamin, M
    JOURNAL OF ANATOMY, 2002, 200 (02) : 145 - 152
  • [9] Biomechanical comparison of three methods for distal Achilles tendon reconstruction
    Wu, Ziying
    Hua, Yinghui
    Li, Hongyun
    Chen, Shiyi
    Li, Yunxia
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3756 - 3760
  • [10] Biomechanical comparison of three methods for distal Achilles tendon reconstruction
    Ziying Wu
    Yinghui Hua
    Hongyun Li
    Shiyi Chen
    Yunxia Li
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3756 - 3760