Wireless Impedance Sensor with PZT-Interface for Prestress-Loss Monitoring in Prestressed Concrete Girder

被引:0
|
作者
Nguyen, Khac-Duy [1 ]
Lee, So-Young [1 ]
Kim, Jeong-Tae [1 ]
机构
[1] Pukyong Natl Univ, Dept Ocean Engn, Busan 608737, South Korea
基金
新加坡国家研究基金会;
关键词
Prestress-Loss; Automated Monitoring; Imote2; Impedance Sensor Node; PZT-Interface; Prestressed Concrete Girder;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Ensuring the designed prestress force is very important for the safety of prestressed concrete bridge. The loss of prestress force in tendon could significantly reduce load carrying capacity of the structure. In this study, an automated prestress-loss monitoring system for prestressed concrete girder using PZT-interface and wireless impedance sensor node is presented. The following approaches are carried out to achieve the objective. Firstly, wireless impedance sensor nodes are designed for automated impedance-based monitoring technique. The sensor node is mounted on the high-performance Imote2 sensor platform to fulfill high operating speed, low power requirement and large storage memory. Secondly, a smart PZT-interface designed for monitoring prestress force is described. A linear regression model is established to predict prestress-loss. Finally, a system of the PZT-interface interacted with the wireless sensor node is evaluated from a lab-scale tendon-anchorage connection of a prestressed concrete girder.
引用
收藏
页码:616 / 625
页数:10
相关论文
共 28 条
  • [1] Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection
    Khac-Duy Nguyen
    Kim, Jeong-Tae
    [J]. SMART STRUCTURES AND SYSTEMS, 2012, 9 (06) : 489 - 504
  • [2] Compensation of temperature effect on impedance responses of PZT interface for prestress-loss monitoring in PSC girders
    Huynh, Thanh-Canh
    Kim, Jeong-Tae
    [J]. SMART STRUCTURES AND SYSTEMS, 2016, 17 (06) : 881 - 901
  • [3] Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges
    Kim, Jeong-Tae
    Park, Jae-Hyung
    Hong, Dong-Soo
    Cho, Hyun-Man
    Na, Won-Bae
    Yi, Jin-Hak
    [J]. SMART STRUCTURES AND SYSTEMS, 2009, 5 (01) : 81 - 94
  • [4] Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder
    Park, Jae-Hyung
    Huynh, Thanh-Canh
    Kim, Jeong-Tae
    [J]. SMART STRUCTURES AND SYSTEMS, 2015, 15 (04) : 1159 - 1175
  • [5] Vibration-based damage monitoring algorithms for prestress-loss in PSC girder bridges
    Kim, Jeong-Tae
    Na, Won-Bae
    Ryu, Yeon-Sun
    Park, Jae-Hyung
    Lee, Jung-Mi
    Lee, So-Young
    [J]. SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2008, PTS 1 AND 2, 2008, 6932
  • [6] Prestress-force Monitoring of PSC Girder Bridges using Wireless Impedance Sensor Nodes
    Park, Jae-Hyung
    Lee, So-Young
    Hong, Dong-Soo
    Kim, Jeong-Tae
    [J]. SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2010, 2010, 7647
  • [7] Feasibility Verification of Mountable PZT-Interface for Impedance Monitoring in Tendon-Anchorage
    Thanh-Canh Huynh
    Park, Young-Hwan
    Park, Jae-Hyung
    Kim, Jeong-Tae
    [J]. SHOCK AND VIBRATION, 2015, 2015
  • [8] Monitoring and Analysis of Prestress Loss in Prestressed Box Girder Bridges Strengthened with External Prestressing
    Guo, Haoran
    Yang, Jing
    Tang, Renjie
    Yang, Caiqian
    Xu, Fu
    [J]. SENSORS, 2024, 24 (14)
  • [9] Monitoring cracks and prestress-loss in PSC girder bridges using vibration-based damage detection techniques
    Park, Jae-Hyung
    Kim, Jeong-Tae
    Ryu, Yeon-Sun
    Lee, Jung-Mi
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2007, 2007, 6532