TRABECULAR BONE REMODELING - AN EXPERIMENTAL-MODEL

被引:138
|
作者
GOLDSTEIN, SA
MATTHEWS, LS
KUHN, JL
HOLLISTER, SJ
机构
[1] The Orthopaedic Research Laboratories, The University of Michigan, Section of Orthopaedic Surgery, Ann Arbor
关键词
D O I
10.1016/0021-9290(91)90384-Y
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An experimental model, capable of inducing controlled stress fields to the distal femoral metaphyses of large dogs, is presented. This model utilized an implantable hydraulic device incorporating five loading cylinders and platens in direct contact with an exposed plane of trabecular bone. A microprocessor controls the loading characteristics, and finite element models were created to calculate the induced stress and strain fields. The trabecular remodeling response is measured using serial in vivo computed tomography, in vitro microcomputed tomography, and histologic analysis. The results of the experiment indicate that significant remodeling can be induced by the activated implant. An increase in trabecular orientation toward the loaded platens was observed, and a statistically significant decrease in connectivity was documented. The greatest effect was associated with a change in the loading rate. A fast rise time (70 ms) loading waveform induced significant bone ingrowth at the implant interface when compared to a slow rise time waveform (700 ms), and demonstrated high correlations with the calculated stress fields as remodeling approached an equilibrium state.
引用
收藏
页码:135 / +
页数:1
相关论文
共 50 条
  • [1] TRABECULAR BONE REMODELING - AN EXPERIMENTAL-MODEL (VOL 24, PG 135, 1991)
    GOLDSTEIN, SA
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (03) : 367 - 367
  • [2] Subchondral and trabecular bone remodeling in canine experimental osteoarthritis
    A. Lahm
    P.C. Kreuz
    M. Oberst
    J. Haberstroh
    M. Uhl
    D. Maier
    [J]. Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 582 - 587
  • [3] Subchondral and trabecular bone remodeling in canine experimental osteoarthritis
    Lahm, A.
    Kreuz, P. C.
    Oberst, M.
    Haberstroh, J.
    Uhl, M.
    Maier, D.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (09) : 582 - 587
  • [4] TRABECULAR BONE REMODELING
    GOLDSTEIN, SA
    KU, JL
    KAYNER, DC
    HOLLISTER, S
    MATTHEWS, LS
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (06) : 473 - 473
  • [5] EXPERIMENTAL-MODEL OF A MALIGNANT BONE TUMOR
    SPIRA, E
    BARNEA, A
    TRAININ, Z
    TADMOR, A
    [J]. INTERNATIONAL ORTHOPAEDICS, 1977, 1 (01) : 16 - 18
  • [6] Trabecular bone organoid model for studying the regulation of localized bone remodeling
    Park, Yongkuk
    Cheong, Eugene
    Kwak, Jun-Goo
    Carpenter, Ryan
    Shim, Jae-Hyuck
    Lee, Jungwoo
    [J]. SCIENCE ADVANCES, 2021, 7 (04)
  • [7] BONE ALLOGRAFT ANTIGENICITY IN AN EXPERIMENTAL-MODEL AND IN MAN
    FRIEDLAENDER, GE
    SELL, KW
    STRONG, DM
    [J]. ACTA MEDICA POLONA, 1978, 19 (1-2) : 197 - 205
  • [8] BONE CELL-CULTURES AS AN EXPERIMENTAL-MODEL
    WONG, GL
    [J]. ARTHRITIS AND RHEUMATISM, 1980, 23 (10): : 1081 - 1086
  • [9] PERMANENT DEFORMATION OF BONE - EXPERIMENTAL-MODEL IN DOG
    MOSELEY, CF
    FRANKEL, VH
    BURSTEIN, AH
    HEIPLE, KG
    [J]. CANADIAN JOURNAL OF SURGERY, 1976, 19 (04) : 336 - 336
  • [10] Surface remodeling of trabecular bone using a tissue level model
    Smith, TS
    Martin, RB
    Hubbard, M
    Bay, BK
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (04) : 593 - 600