AN IMMUNOSENSOR FOR SYPHILIS SCREENING BASED ON SURFACE-PLASMON RESONANCE

被引:37
|
作者
SEVERS, AH [1 ]
SCHASFOORT, RBM [1 ]
SALDEN, MHL [1 ]
机构
[1] EURO-DIAGNOST BV,7303 GC APELDOORN,NETHERLANDS
来源
BIOSENSORS & BIOELECTRONICS | 1993年 / 8卷 / 3-4期
关键词
IMMUNOSENSOR; SURFACE PLASMON RESONANCE; SYPHILIS; TREPONEMA-PALLIDUM MEMBRANE PROTEIN-A;
D O I
10.1016/0956-5663(93)85031-I
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper the development of a surface plasmon resonance (SPR) immunosensor for syphilis screening is described. This immunosensor is based on the detection of antibodies in serum against the causative organism Treponema pallidum. In order to achieve selectivity a recombinant Treponema pallidum membrane protein A (TmpA) was used. This antigen can react with antibodies to T. pallidum, present in serum of syphilitic patients. Reproducible results have been obtained, using a 'sandwich SPR' method: binding of a sandwich antibody to the treponemal antibody after serum incubation was measured in real time while the binding was taking place. The SPR results obtained from ten blind-coded sera corresponded well with classical syphilis tests (Treponema pallidum haemagglutination assay (TPHA), fluorescent treponemal antibody-absorbed test (FTA-ABS), venereal diseases research laboratory flocculation test (VDRL) and TmpA-based enzyme-linked immunosorbent assay (TmpA-ELISA)). Preliminary experiments showed that direct measurement of serum (in the 'one step SPR') is not yet possible, probably as a result of non-uniformity of serum samples. The application of latex beads is considered to solve this problem.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 50 条
  • [1] A SURFACE-PLASMON RESONANCE IMMUNOSENSOR BASED ON THE STREPTAVIDIN BIOTIN COMPLEX
    MORGAN, H
    TAYLOR, DM
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (06): : 405 - 410
  • [2] VIBRATING MIRROR SURFACE-PLASMON RESONANCE IMMUNOSENSOR
    KOOYMAN, RPH
    LENFERINK, ATM
    EENINK, RG
    GREVE, J
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (01) : 83 - 85
  • [3] ANALYSIS OF SULFAMETHAZINE IN MILK BY A SURFACE-PLASMON RESONANCE IMMUNOSENSOR ASSAY
    STERNESJO, A
    MELLGREN, C
    BJORCK, L
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 56 - BTEC
  • [4] BIOANALYSIS WITH SURFACE-PLASMON RESONANCE
    LOFAS, S
    MALMQVIST, M
    RONNBERG, I
    STENBERG, E
    LIEDBERG, B
    LUNDSTROM, I
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) : 79 - 84
  • [5] SURFACE-PLASMON RESONANCE AND IMMUNOSENSORS
    FLANAGAN, MT
    PANTELL, RH
    [J]. ELECTRONICS LETTERS, 1984, 20 (23) : 968 - 970
  • [6] AN INVERTED SURFACE-PLASMON RESONANCE
    PRINTZ, M
    SAMBLES, JR
    [J]. JOURNAL OF MODERN OPTICS, 1993, 40 (11) : 2095 - 2104
  • [7] Interferometer based on a surface-plasmon resonance for sensor applications
    Kabashin, AV
    Nikitin, PI
    [J]. QUANTUM ELECTRONICS, 1997, 27 (07) : 653 - 654
  • [8] OPTIMIZATION OF A CHEMOOPTICAL SURFACE-PLASMON RESONANCE BASED SENSOR
    VANGENT, J
    LAMBECK, PV
    KREUWEL, HJM
    GERRITSMA, GJ
    SUDHOLTER, EJR
    REINHOUDT, DN
    POPMA, TJA
    [J]. APPLIED OPTICS, 1990, 29 (19): : 2843 - 2849
  • [9] Studies on an immunosensor of albumin based on surface plasmon resonance
    Zhao, XJ
    Mu, Y
    Wang, Z
    Zhang, HQ
    Jin, QH
    Xu, HY
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1999, 20 (05): : 704 - 708
  • [10] Immunosensor Based on Surface Plasmon Resonance for Antigen Recognition
    JIN Wei1
    2. College of Instrumentation and Electrical Engineering
    3. College of Chemistry
    [J]. Chemical Research in Chinese Universities, 2008, (01) : 24 - 28