Research of Physiological Monitoring System Based on Optical Fiber Sensor

被引:1
|
作者
Zhao Rongjian [1 ,2 ]
Tang Minfang [1 ,2 ]
Chen Xianxiang [1 ]
Du Lidong [1 ]
Zeng Hualin [3 ]
Zhao Zhan [1 ,2 ]
Fang Zhen [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Informat Engn, Beijing 100093, Peoples R China
关键词
Fiber optic sensor; Ballistocardiogram; Heart rate; Respiration rate;
D O I
10.11999/JEIT170894
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventionally, the physiological monitoring system obtains singnal by electrode or bandage which is connected with skins and has disadvantages such as: uncomfortable and bad compliance to users. In order to overcome those problems, a new physiological monitoring system, which is based on the principle that micro bend of optical-fiber induced by weak movement of physiology can change the light intensity to get BallistoCardioGram (BCG) signal, is developed. In such system, the respiration rate, heart rate and body movement are obtained by self-adaption detecting the tiny variation of light intensity. In order to protect fiber and enhance the stability and reliability of system, the fiber is embedded into mattress or cushion with a sandwich structure. Simultaneously, it makes the system have high sensitivity that the fiber is uniformly routed with serpentine-curve shape in the middle of mattress or cushion. It is illustrated by the measurement in several hospitals that the mean error of heart rate is -0.26 +/- 2.80 times/min within 95% the confidence interval (+/- 1.96SD) with a correlation 0.9984 to the standard values. It is exhibited as well that the mean error respiration rate is 0.41 +/- 1.49 times/min within 95% the confidence interval (+/- 1.96SD) with a correlation 0.9971 to the standard values. It is suggested that the developed system can be senselessly used under zero load and is promised in future.
引用
收藏
页码:2182 / 2189
页数:8
相关论文
共 18 条
  • [1] Chen ZH, 2014, IEEE ENG MED BIO, P5377, DOI 10.1109/EMBC.2014.6944841
  • [2] Simultaneous measurement of breathing rate and heart rate using a microbend multimode fiber optic sensor
    Chen, Zhihao
    Lau, Doreen
    Teo, Ju Teng
    Ng, Soon Huat
    Yang, Xiufeng
    Kei, Pin Lin
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (05)
  • [3] Deepu CJ, 2012, BIOMED CIRC SYST C, P53, DOI 10.1109/BioCAS.2012.6418512
  • [4] FAUSTMAN D L, 2017, WO, Patent No. 2017059132A1
  • [5] [高发荣 Gao Farong], 2015, [电子与信息学报, Journal of Electronics & Information Technology], V37, P1154
  • [6] Heart rate estimation using facial video: A review
    Hassan, M. A.
    Malik, A. S.
    Fofi, D.
    Saad, N.
    Karasfi, B.
    Ali, Y. S.
    Meriaudeau, F.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 38 : 346 - 360
  • [7] Jose SK, 2015, PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON COMPUTING AND COMMUNICATIONS TECHNOLOGIES (ICCCT 15), P128, DOI 10.1109/ICCCT2.2015.7292732
  • [8] Low-power, noninvasive measurement system for wearable ballistocardiography in sitting and standing positions
    Liu, Mengxing
    Jiang, Feng
    Jiang, He
    Ye, Shuming
    Chen, Hang
    [J]. COMPUTERS IN INDUSTRY, 2017, 91 : 24 - 32
  • [9] Ni Hongbo, 2017, P INT C SMART HOM HL, P37
  • [10] Respiration and body movement analysis during sleep in bed using hetero-core fiber optic pressure sensors without constraint to human activity
    Nishyama, Michiko
    Miyamoto, Mitsuo
    Watanabe, Kazuhiro
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)